- 4 - 

L12: Charging status indicator. 

 
3.3 Description of L3 ports 

 

3.4 installation of the host 

      Switch off the power. Open the cover at the bottom and insert a GSM SIM card (has the functions 
of calling and receiving /sending message and incoming caller display), install the antenna and finally 
connect the power cable. 

3.5 Installation of the detector 

      Passive IR wireless detector should be visibly installed at the central position of defense area, with 
proper height and angle, the wireless door-magnet detector should be installed as per the minimum 
angle of opening the door, the distance between the magnet and magnetic switch should be shorter 

Note:   

L5: Turn on in case of external power supply, turn off of no external power supply 
L6: It is means arming status if the green indicator blinks and means disarming status if always 
lighted.   
L7: Red indicator means the host is busy (alarming, sending message and calling) 
L8: Network signal indicator, at means it's in searching status if the indicator blinks with time 
interval of on a second.it means the network signal is normal if the indicator keeps on for one 
second and keeps off for three seconds. If not, the SIM card or network is not n normal use.it 
means it's in calling status if it always keeps on. 
L9: Running status indicator of the host, when alarm is activated, the indicator is turned on with 
beep sound. 
L10: Linkage output indicator, the indicator always keeps on when the linkage relay is closed. 
L11: Microphone one monitoring status indicator, it means it's in monitoring status if the 
indicator is turned on, and it's means the monitoring function is closed if the indicator is turned 
off. 
L12: Charging status indicator, the indicator always keeps on when charging till it's fully charged. 

Summary of Contents for s3523

Page 1: ...GSM SMS Alarm TMPI User Manual Ver 1 1 Date Issued 2012 10 08 ...

Page 2: ... 1 Table of contents 1 System Introduction 2 2 Features 2 3 Installation 3 4 System Setup 5 5 Use Method 10 6 System Configurations 11 7 Technical Specifications 11 8 Trouble Shooting 12 ...

Page 3: ... as troubled wire arrangement bad stability and easy to be damaged Well designed circuit structure user friendly operating interface and remote control embody the human oriented design concept and make your convenient and easy to use and operate the unit 2 Features 1 GSM dual frequency four frequency network are applicable all countries and regions in the world 2 Back up power ensures smooth trans...

Page 4: ...position the emergency button and foot touch switch should be installed at the convenient positions 3 The power cable of the host should be concealed and connected in good condition good heat emission is required keep it away from flammable materials 4 Switch off the power before removing installing SIM card 5 The batteries of detectors and controller should be regularly checked and replaced in ti...

Page 5: ...n indicator blinks and means disarming status if always lighted L7 Red indicator means the host is busy alarming sending message and calling L8 Network signal indicator at means it s in searching status if the indicator blinks with time interval of on a second it means the network signal is normal if the indicator keeps on for one second and keeps off for three seconds If not the SIM card or netwo...

Page 6: ...oscillation resistance 4 7MHZ and emission frequency 315MHz or 433MHz of the detector consistently to the host The codes on the back of the remote controller should be same as A0 A7 on the detector 0 means the connection of N and L H Set up codes from A0 to A7 at the coding area of the detector consistent to the ones of the remote controller and other wireless detector controller that is matched w...

Page 7: ...less defense 3 0xF0 H H L L Wireless defense 4 0xF3 H H L H Wireless defense 5 0xFC H H H L Wireless defense 6 0xFF H H H H Wireless defense 7 0xC3 H L L H Wireless defense 8 0x33 L H L H Notice It s 1 when hopping N and H it s 0 when hopping N and L it s 2 when N H and L are not hopped Example 1 set up the first defense area of 12 pin wireless detector Code on the back of the controller Setup the...

Page 8: ...eiving an alarm 12 The host will reply the three alarm numbers by message host s status when arming disarming defense by the controller 12 Close the function of replying the alarm number by message default 21 Set up the wired defense area as open circuit alarm 21 Set as closed circuit alarm default 31 Change the password Ex change to 5678 edit and send 1234 5678 to the host 40 Inquire the preset m...

Page 9: ...faulted contents wireless defense area 3 84 Set up the message contents of wireless defense area 4 six characters at most initial defaulted contents wireless defense area 4 85 Set up the message contents of wireless defense area 5 six characters at most initial defaulted contents wireless defense area 5 86 Set up the message contents of wireless defense area 6 six characters at most initial defaul...

Page 10: ... means which group number is to the host and the host will reply the mobile phone by message after receiving Ex set up 21000000 as the first auto dialing alarm number and the host number is 0001 edit and send 1234 51 21000000 0001 to the host the host will reply the mobile phone by message after receiving repeat the above operations or use one message to edit several orders to finish the setup of ...

Page 11: ...rminal occurs short circuit if you want switch to open circuit edit and send 1234 21 to the host and the host will reply the mobile phone by message after receiving if you want to switch to short circuit edit and send 1234 21 to the host and the host will reply the mobile phone by message after receiving 4 4 10 Change of the host s password When the host is in normal use edit and send 1234 31 new ...

Page 12: ...o the mobile phone to tell the recovery of power supply and call the three alarm receiving numbers circularly 5 5 Alarm treatment In case of alarm the host will automatically start the alarm horn for 90 seconds to alert the people and meanwhile send message shows the name of the defense area and call the preset alarm receiving number and monitor the on site conditions The user may answer the phone...

Page 13: ...the operation of code hopping or matching or rematch after resetting 3 The host has no response but only the green indicator blinks for a while after the remote controller or detector emits signal the host number is not set up or the host has not order received 4 The user couldn t receive message or call from the host the GSM SIM card has no money or has been out of the validity or the communicati...