Honeywell Vista Automation Module Installation & Setup Manual Download Page 3

– 3 –

 

 

Program the Control Panel for using VAM

 

At the control, assign an appropriate touchscreen (AUI) type 
device address (ECP address) for VAM, and set a partition (if 
applicable).  
Refer to the control panel’s programming instructions for detailed 
procedures.  
After enabling the VAM device address in the control panel, set 
the VAM to the selected address. See section below. 

 

On VISTA

®

 Plus series or equivalent 

Use data field *189 to enable an unused device address 1, 2, 
5 or 6 for VAM. Addresses 1 and 2 are enabled by default.  

 

On VISTA

®

 Turbo and Commercial VISTA Series  

(VISTA-128BP, VISTA-128FBP, etc.) 

Use #93 Menu mode to enable an unused device address. 

  For older controls under Rev. 10, addresses 1-2, and 3-30 

may be used.  

  For VISTA Turbo series controls Rev. 10 and higher, 

addresses 1-30 may be used. These addresses are 
normally not defaulted for AUI type devices. 

 

If using Remote Services 

Enable an appropriate RIS address in the control panel and 
enable the remote service (RIS) option if applicable. 
 

Program the VAM Device Address

 

VAM Device Address 

Default VAM device address = 1. 
1.  Click 

Setup

 > 

System

.  

2.  Click 

ECP Address

.  

 

Using the Up/Dn arrows, choose the device address assigned 
for VAM in the control panel.  

3.  Click 

Apply

4.  VAM automatically reboots after the device address is set. 

 

Remote Services Option 

 

Set the Time & Date 

Set the time and date manually or retrieve the time and date from 

the control panel (if programmed). 

Get Time/Date from the Control Panel 

1.  Click 

Setup

 > 

System

 >

 Time/Date Setup

2.  Click the 

Get Time

 button. 

 

The VAM retrieves the time and date programmed in the 
control panel. 

Manually Set the Time/Date 

1.  Click 

Setup

 > 

System

 > 

Time/Date Setup

2.  Select the Month, Year, Hour, and Minutes using the drop-

down arrows for each. 

3.  Select 

AM

 or 

PM 

(selection toggles by clicking) 

4.  Select the desired date format using the 

MMDDYY

 drop-down 

arrow. Choose 12-hour (select the 12 Hour checkbox) or 24-
hour format (uncheck the checkbox). 

5.  If Daylight Saving Time is used in the installation time zone, 

click 

DST 

and set the appropriate start and end DST month, 

weekend and hour. VAM will automatically adjust the time 
when Daylight Saving Time starts and ends. 

6.  Click 

Apply

 to save the settings. 

7.  A choice (checkmark = Yes; X = No) to copy the time to the 

control panel may appear. Select 

Yes

 or 

No

 as desired. 

Choosing “yes” sets the control panel to the time entered in 
VAM. 

 

Set Up Email Notification  

Users (and/or the installer) can receive email notifications when 
one or more selected system events or conditions occur.  

NOTE:

  Email  notification  requires  that  the  user  has  an  active 

email address. 

1.  Click 

Setup

 then select 

Email

2.  Click 

User SMTP

 to assign the user’s email server 

information. SMTP establishes the email server domain (the 
“from” address). 

 

a. Choose the email server name (email provider) from the 

drop-down menu. Choose from GMAIL, OUTLOOK, 
YAHOO, or Add New. 

 

b. Enter the email ID (user name) and password for the 

chosen email server. 

 

c. The Email Server and SMTP port number fields are 

automatically filled unless “Add New” was selected.  

 

  If Add New selected, enter the appropriate SMTP and port 

number information (see your email provider for details). 

 

d. Click 

Save

3.  Click 

Event 1 

to define the event types and conditions that will 

trigger notifications to the chosen email address(es).  

4.  Enter up to four email address(es) to which Event 1 will send 

notifications.  

5.  Click 

Save

6.  Repeat steps 3 -5 for Events 2-4 if desired. 

 

Set Up Remote Services (Total Connect™) 

An AlarmNet Direct account is required to enable Total Connect, 
and a communication device must be connected to the VISTA

®

 

control panel. 
1.  Verify that the VAM is connected to the Internet via the 

network router.  

2.  Using AlarmNet Direct, enroll the communication device and 

VAM, and enable Total Connect usage. Select Yes at the 
“using VISTA Automation Module” (Yes /No) prompt. You will 
need the VAM MAC ID and CRC number, which can be found 
on a label on the back of the VAM or on its carton. 

3.  Open a Total Connect account for the user if an account does 

not already exist.  

4.   After a Total Connect account has been set up, the VAM must 

be reset (powered down and powered up). 

5.  Enable the desired automation devices to be controlled by 

Total Connect. See “Enabling Devices for Total Connect“ 
section. After devices have been enabled for Total Connect, 
follow the Total Connect prompts to synchronize the data with 
VAM. Syncing is required before the enabled devices will 
display in Total Connect. 

 

Enabling Devices for Total Connect  

1.  Click the 

Setup

 > 

System

 > 

TC Server

 

2.  Click the 

TC

 

Enable 

 button to display the “Z-Wave Device 

Management For Total Connect” screen. 

3.  Select the device(s) to be enabled for Total Connect usage.  

NOTE:

 Some devices may need to be re-enabled after a 

software upgrade. 

4.  Click 

Save

 when done. 

5.  Follow the Total Connect prompts to synchronize the data with 

VAM. Syncing is required before the enabled devices will display 
in Total Connect. 

NOTES: 

1. Device IDs for Z-Wave devices could be different on 

VAM and Total Connect web pages. 

 

2. Total Connect supports the first 40 switches, the first 3 

thermostats, and the first 4 door locks enrolled in VAM. 

 

 

 

Summary of Contents for Vista Automation Module

Page 1: ...it does use a supplementary power supply as shown IMPORTANT When VAM is powered from an auxiliary power supply always apply power to the control panel first and then VAM Failure to observe this sequence results in improper operation of VAM and may result in an ECP Error indication pwr_supp_conn 011 V0 BLACK POWER FROM SUPPLEMENTARY POWER SUPPLY IF USED RED BLACK GREEN YELLOW CONTROL TERMINAL STRIP...

Page 2: ...teps must be repeated to connect the VAM to the new router 1 Connect a smart device to VAM a Power up the VAM b Connect the smart device to the VAM using the device s WiFi settings menu VAM is a wireless access point Enter the VAM SSID VAM_xxxx SSID is case sensitive NOTE xxxx the last 4 digits of the MAC address Enter the Key found on the VAM label WPA2 pw line 2 Access VAM s home screen a Open a...

Page 3: ...e or more selected system events or conditions occur NOTE Email notification requires that the user has an active email address 1 Click Setup then select Email 2 Click User SMTP to assign the user s email server information SMTP establishes the email server domain the from address a Choose the email server name email provider from the drop down menu Choose from GMAIL OUTLOOK YAHOO or Add New b Ent...

Page 4: ...on to 320 x 240 8 frames per sec Normal quality 5 Click the Add button if the camera information is not discovered automatically to enter information manually 6 To edit camera information highlight the camera name and click the Edit button Enter required information and then click Save Automation Creating Scenes The system can automatically activate various devices when certain events occur based ...

Page 5: ...l Z wave devices have been tested and some features may produce unpredictable results Using VAM as a Secondary Controller VAM can be used as a secondary controller when connected to another Z Wave network 1 Remove any Z Wave devices previously included in VAM Click Automation Z Wave Setup to display the Z Wave Management screen then click Z Wave Default and select Yes 2 Press the Z Wave Primary bu...

Page 6: ...te access lets the user access VAM s menus directly via the Internet when away from home The home router must first be configured for port forwarding Refer to the router s instructions for details on port forwarding To set up a remote access log in do the following 1 Click Setup Account 2 Enter the desired user name and password Passwords must be a minimum of 8 alphanumeric characters and must inc...

Page 7: ...n for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES 003 Cet Appareil numérique de la classe B est conforme à la norme NMB 003 du Canada FEDERAL COMMUNICATIONS COMMISSION FCC PART 15 This device complies with Part 15 of the FCC Rules and RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause har...

Reviews: