Installation Guide
69-1816EFS—09 2
Installer setup
Setup function
Settings & options (factory default in bold)
0110
Zone number
0
Not zoned
1–9 Zone number
0120
Year
(first two digits)
20
(
20
00-
20
99)
21
(21
00-
21
78)
0130
Year
(second two digits)
06
(20
06
)
[Other options: 00-99]
0140
Month
6
[Other options: 1-12]
0150
Date
15
[Other options: 1-31]
0160
Schedule format
4
7-day programming
0 Non-programmable
0172
System type
1 Conventional
2
Heat pump
3
Heat only (no fan)
E
Auto Discover
**
0173
Heat Pump Type
0
Air to Air heat pump
1
Geothermal heat pump
0174
Cooling compressor
stages
1
1 stage of cool
[Other options: 0 or 2 stages, or E]
0176
Heat or Heat Pump
Aux stages
1
1 stage of heat
[Other options: 0, 2 or 3 stages, or E]
0180
Fan control
(conventional heat)
0
Gas/Oil heat (equipment controls heating fan)
1
Electric furnace (thermostat controls heating fan)
2
Equipment controls stage 1, thermostat controls stage 2+
E
Auto Discover
**
0190
Changeover valve
(O/B terminal)
0
O/B terminal controls valve in cooling
1
O/B terminal controls valve in heating
0200
Backup heat
(Aux & EmHeat)
E
Auto Discover
**
0
Electric backup heat
1
Fossil fuel backup heat
0210
External fossil
fuel kit
1
External fossil fuel kit controls backup heat
0
Thermostat controls backup heat (outdoor sensor required)
Installer setup
**See page 6
1
Press
SYSTEM
Press
DONE
to save & exit
2
Press and hold for 5 seconds
3
Change settings (see p. 2-6)
SCHED
HOLD
TUE
FAN
AUTO
Inside
70
6
aM
6:00
SYSTEM
HEAT
DONE
TUE
Inside
70
20
0120
Function
Setting
Press
s
t
to change
DONE
TUE
Inside
70
20
0120
DONE
CANCEL
TUE
aM
6:00
SYSTEM
HEAT