Honeywell Velociti Series Installation And Maintenance Instructions Download Page 2

The MBB-2 cabinet has a built-in chassis that will accommodate one or two 
MMI-6SF modules.

FIGURE 2. MBB-2 CABINET

 

0

1

2 3 4 5 6

7

8

9

0

7

8

6

5

4

3

2

1

9

10

11

12

13

14

15

B

A

S

E

 A

D

D

R

E

S

S

A

D

D

R

E

S

S

D

IS

A

B

LE

N

O

N

E

ON
E

TW

O

THR
EE

0

1

2 3 4 5 6

7

8

9

0

7

8

6

5

4

3

2

1

9

10

11

12

13

14

15

B

A

S

E

 A

DDRE

S

S

A

DD
R

E

S

S

DI

S

A

B

LE

NONE

ON
E

TW

O

THR
EE

  C0234-00

The front MMI-6SF module positions of each chassis are offset below the rear 
MMI-6SF module positions so that all of the status indicators are visible.

CABINETS

An MBB-6, CAB-3 or CAB-4 Series cabinet will house the CHS-6 chassis with 
up to six MMI-6SF modules installed on it. Refer to cabinet installation docu-
ments for dimensions.

The MBB-2 cabinet houses one or two MMI-6SF modules on the internal chas-
sis that is part of the cabinet.  Refer to cabinet installation documents for 
dimensions. 

INSTALLATION STEPS

1.  Cabinet Mounting

In a clean, dry area, mount the backbox using the four holes provided in the 
back surface of the cabinet (Figure 3).

2.  Chassis Installation

The CHS-6 chassis is mounted in the MBB-6, CAB-3 or CAB-4 Series cabinet. It 
is shipped with two self-threading screws, which are used to fasten the chassis 
to the back wall of the cabinet (Figure 4).

FIGURE 3. TYPICAL MOUNTING HOLE LOCATIONS

 

BACKBOX
MOUNTING
HOLES

C0235-00

FIGURE 4. MOUNTING THE CHS-6 CHASSIS

MOUNT WITH

SELF-THREADING SCREWS 

TO BACK OF CABINET

C0236-00

The MBB-2 cabinet comes with the chassis already installed, so no mounting 
is necessary.

3.  Module Installation

There are two methods for installing a module in the rear position of 

a chassis. Method one is for installation of a rear module only, when 
no module will be installed in front of it. Refer to Figure 5 for instruc-
tions. Method two is for installation of a rear module when another mod-
ule will be installed in the chassis position in front of it. Refer to Figures  
6A – 6C for method two. All necessary screws and standoffs are supplied with 
the modules.

FIGURE 5. INSTALLATION OF REAR MODULE ONLY, METHOD ONE

 

2

3

1

 

C0237-00

Step 1:   Insert the bottom of the MMI-6SF module down into a rear slot on the 

chassis. 

Step 2:    Carefully swing the upper edge of the board back towards the back of 

the chassis until it touches the two standoffs.

Step 3:  Align two 4-40 screws with the two standoffs and tighten.
Step 4:   Address and wire the modules according to the instructions in 

this manual.

The steps in Figures 6A – 6C describe and illustrate module installation when 
the rear chassis position and the position in front of it will be filled.  Front 
position installation is possible only if the rear position is filled with an MM 
module.

FIGURE 6A. INSTALLATION OF MMI-6SF MODULE IN A REAR 

CHASSIS POSITION, METHOD TWO

 

1

 C0225-01

FIGURE 6B.

 

3

2

4

 C0249-01

Step 1:    Install two long standoffs in the lower mounting holes using two 4-40 

nuts as shown.

Step 2:   Insert the bottom of the MMI-6SF module down into a rear slot on the 

chassis.

Step 3:   Carefully swing the upper edge of the board back towards the back of 

the chassis until it touches the two standoffs on the board.

Step 4:   Align two 4-40 screws with the two standoffs on the chassis and 

tighten.

Step 5:   Address and wire the modules according to the instructions in this 

manual.

  

I56-2742-009 

 

 7/1/2022

Summary of Contents for Velociti Series

Page 1: ...ICATIONS Normal Operating Voltage 15 32VDC Standby Current 2 3 mA 24 V Alarm Current 40 mA assumes all six LEDs solid on Temperature Range 32ºF to 120ºF 0ºC to 49ºC Humidity 10 to 85 Non condensing Dimensions 6 8 H x 5 8 W x 1 0 D Accessories CHS 6 Chassis MBB 6 Cabinet MBB 2 Cabinet CAB 4 Series Cabinets CAB 3 Series Cabinets Wire Gauge 12 18 AWG Maximum IDC Wiring Resistance 25 Ohms External Pow...

Page 2: ...for installing a module in the rear position of a chassis Method one is for installation of a rear module only when no module will be installed in front of it Refer to Figure 5 for instruc tions Method two is for installation of a rear module when another mod ule will be installed in the chassis position in front of it Refer to Figures 6A 6C for method two All necessary screws and standoffs are su...

Page 3: ...be used for other modules on the SLC For Class A and B operation DO NOT set the lowest address above 154 as the other modules will be assigned to nonexistent addresses NOTE The MMI 6SF must have power cycled for shunt changes to take effect NOTE Some panels support extended addressing In order to set the module above address 99 on compatible systems carefully remove the stop on the upper rotary sw...

Page 4: ...he two shunts from the A B select positions 2 To use a common power supply between multiple MMI 6SF modules connect a long power supply jumper from T5 or T6 to T5 or T6 on the adjacent MMI 6SF module FIGURE 10 RELAY CONTROL MODULE USED TO DISCONNECT A POWER SUPPLY C0248 00 4 I56 2742 009 7 1 2022 ...

Page 5: ...e harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the ...

Reviews: