CHECKOUT PROCEDURE

To ensure the valve is plumbed and wired correctly, carry out 

the following checks after filling the system and switching on 

the power:

1.

a. Check the manual lever is in ‘AUTO’ position.

b. Check programmer has power.

c. Check boiler is switched on and its thermostat set to 

maximum.

2.

Confirm correct hot water functions as follows:

a. Turn room thermostat to minimum setting or switch 

off at programmer.

b. Set cylinder thermostat to maximum and program-

mer to ‘HOT WATER ON’.

c. Pump should run (S Plan ONLY) and boiler should 

fire (S and C Plan). Feel pipe approximately 12” 

from valve port B, it should get hot.

3.

Confirm correct heating functions as follows:

a. Turn cylinder thermostat to minimum or switch off at 

programmer.

b. Set room thermostat to maximum and programmer 

to ‘CENTRAL HEATING ON’.

c. Boiler should fire and pump should run. Feel pipe 

approximately 12” from pump (C Plan), or valve (S 

Plan) it should get hot.

COMPLETION

Reset both thermostats to temperature required, normally 60° 

C for cylinder thermostat and 20° C for room thermostat. 

Return programmer to ‘Auto’ or mode selected by 

householder. Full installation, wiring and operating 

instructions for SUNDIAL products are included in every 

product pack. For special wiring diagrams or applications, 

contact Honeywell. ENSURE THAT THE VALVE HEADS 

HAVE FREE AIR MOVEMENT AROUND THEM.

Whilst Honeywell takes all practicable steps to design and manufacture its products to comply with the requirements of the Heath 

and Safety at Work Act 1974, all products must be properly used and Purchasers are reminded that their obligations under the 

Act are to ensure that the installation and operation of such products at a place of work should be safe and without risk to them.

Honeywell reserves the right at any time and without notice to change any product or information contained in this publication.

The wiring diagrams and installation instructions in this publication are provided for guidance purposes when installing 

recognised standard systems only. Any application of this product not shown here, or any deviation from these instructions, is 

neither recommended nor advised. Any such application or deviation should be referred to Honeywell for technical assistance.

Summary of Contents for V4043H

Page 1: ...applications SPECIFICATIONS Voltage 230 240V 50 Hz Power Consumption 6W Lead Supplied 1 metre 5 core Operating Temperature Range 5 to 88 C Maximum Ambient Temperature 52 C Pipe Fitting Sizes 22 mm 28 mm compression fitting 3 4 1 BSP Dimensions and KV values See diagrams SPARES AVAILABLE Powerhead Part No 40003916 001 Motor Part No 40002737 003 Ball O Ring Kit Part No 272742A CARD Fig 1 Dimensions ...

Page 2: ...eparation of at least 3 mm in all poles must be incorporated in the fixed wiring as a means of disconnecting the supply The system must be appropriately fused PLUMBING The valve may be plumbed in at any angle but must not be mounted so that the valve head is below the horizontal level of the pipework In the unlikely event of a leak a safety hazard could result Do not grip the valve head while maki...

Page 3: ...terminal 4 or 6 at junction box then link terminal 4 to terminal 6 with a link wire S Plan C Plan Fig 3 Wiring Diagram Note If using the V4043H1080 1 BSP or V4043H1106 28mm the white wire must be electrically isolated S Plan only HEATING ZONE VALVE T6360B ROOM STAT L641A CYLINDER STAT BLUE G YELLOW BROWN GREY G YELLOW GREY ORANGE ORANGE BROWN BLUE L L N N 3 E L N E 4 5 ST699 PROGRAMMER BOILER PUMP...

Page 4: ... pump C Plan or valve S Plan it should get hot COMPLETION Reset both thermostats to temperature required normally 60 C for cylinder thermostat and 20 C for room thermostat Return programmer to Auto or mode selected by householder Full installation wiring and operating instructions for SUNDIAL products are included in every product pack For special wiring diagrams or applications contact Honeywell ...

Reviews: