V4043H MOTORISED ZONE VALVE

3

95C-10819—04

WIRING

The wiring diagram below shows relevant connections to a 

Honeywell junction box (Part No. 42002116-001). Ensure that 

each numbered, lettered or coloured wire is connected to the 

correct terminal in the junction box. Make sure all connections 

are good and all terminal screws are firmly tightened.

NOTES:

a. Wiring diagram shows connections to a programmer 

with separate control of heating and hot water.

b. If single channel time clock is used, connect 

switched live from time clock to terminal 4 or 6 at 

junction box, then link terminal 4 to terminal 6 with a 

link wire.

"S" Plan

"C" Plan

Fig. 3. Wiring Diagram

Note: If using the V4043H1080 (1” BSP) or V4043H1106 (28mm), the white wire must be electrically isolated. (‘S’ Plan only).

HEATING

ZONE 

VALVE

T6360B

ROOM STAT

L641A

CYLINDER

STAT

BLUE

G/YELLOW

BROWN

GREY

G/YELLOW

GREY

ORANGE

ORANGE

BROWN

BLUE

L

L

N

N

3

E

L

N E

4 5

ST699

PROGRAMMER

BOILER

PUMP

10

9

8

7

6

5

4

3

2

1

240 VAC 50 HZ

L

N

E

2 E 1 3

1

2 C

ZONE 

VALVE

HOT WATER

M32277

V4043H

V4043H

6 7 8

ZONE 

VALVE

HOT WATER

T6360B

ROOM STAT

L641A

CYLINDER

STAT

BLUE

G/YELLOW

BROWN

WHITE

ORANGE

L

L

N

N

3

E

L

N E

4 5

ST699

PROGRAMMER

BOILER

PUMP

10

9

8

7

6

5

4

3

2

1

230 VAC 50 HZ

L

N

E

2 E 1 3

1

2 C

M32278

V4043H

6 7 8

GREY

Summary of Contents for V4043H

Page 1: ...applications SPECIFICATIONS Voltage 230 240V 50 Hz Power Consumption 6W Lead Supplied 1 metre 5 core Operating Temperature Range 5 to 88 C Maximum Ambient Temperature 52 C Pipe Fitting Sizes 22 mm 28 mm compression fitting 3 4 1 BSP Dimensions and KV values See diagrams SPARES AVAILABLE Powerhead Part No 40003916 001 Motor Part No 40002737 003 Ball O Ring Kit Part No 272742A CARD Fig 1 Dimensions ...

Page 2: ...eparation of at least 3 mm in all poles must be incorporated in the fixed wiring as a means of disconnecting the supply The system must be appropriately fused PLUMBING The valve may be plumbed in at any angle but must not be mounted so that the valve head is below the horizontal level of the pipework In the unlikely event of a leak a safety hazard could result Do not grip the valve head while maki...

Page 3: ...terminal 4 or 6 at junction box then link terminal 4 to terminal 6 with a link wire S Plan C Plan Fig 3 Wiring Diagram Note If using the V4043H1080 1 BSP or V4043H1106 28mm the white wire must be electrically isolated S Plan only HEATING ZONE VALVE T6360B ROOM STAT L641A CYLINDER STAT BLUE G YELLOW BROWN GREY G YELLOW GREY ORANGE ORANGE BROWN BLUE L L N N 3 E L N E 4 5 ST699 PROGRAMMER BOILER PUMP...

Page 4: ... pump C Plan or valve S Plan it should get hot COMPLETION Reset both thermostats to temperature required normally 60 C for cylinder thermostat and 20 C for room thermostat Return programmer to Auto or mode selected by householder Full installation wiring and operating instructions for SUNDIAL products are included in every product pack For special wiring diagrams or applications contact Honeywell ...

Reviews: