Honeywell TrueZONE ARD Series Installation Instructions Manual Download Page 6

TRUEZONE ARD, EARD, AND ZD SERIES DAMPERS

33-00040—01

6

Fig. 6. EARD with W8835 EnviraZone panel.

1 2 3

1 2 3

1 2 3

L

C

RH

RC

W1/E

W2

W3/AUX

Y1

Y2

G

O/B

HUM

HUM

DEHUM

DEHUM

VENT

VENT

R

C

T1

T2

ZONE1 

M6   M4  M1

ZONE2 

M6   M4  M1

ZONE3 

M6   M4  M1

1    2    3

1    2    3

1    2    3

1    2    3

DAMPERS

ENVIRACOM BUS

DAMPER

XFRM 

ENVIRACOM

XFRM 

REMOVE JUMPERS IF

T1 AND T2 ARE USED 

HEAT

COOL

ZONE 1

COM

EM HEAT

FAN

PURGE

ZONE 3

ZONE 2

W8835A

 DIP SWITCH SETTINGS

 1   SEE TABLE

ON

OFF

 2   SEE TABLE

1

0

 3    ENVIRACOM FURN NO

YES

 4   PURGE TIME

2 MIN

3.5 MIN

 5   PURGE FAN

HVAC

PANEL

 6    PURGE DAMPER

NO CHG

OPEN

 7   # COMP STAGES

1

2

 8    HEAT FAN

HVAC

PANEL

 9    HP CHANGEOVER

O

B

 10 UNUSED

O

N

1  2  3  4  5  6  7  8  9 10

  #1     #2    CONV HT STG

 1     1     1

 1     0     2

 0     1     3

 0     0     HP

24 VOLT/40 VA 

TRANSFORMER

R

C

L1

L2

R

W1

W2

Y1

Y2

G

C

DOTTED LINES FOR 2-

STAGE APPLICATIONS 

SINGLE TRANSFORMER 

HEATING/COOLING SYSTEMS 

REQUIRE A JUMPER TO BE

INSTALLED CONNECTING RH 

AND RC (FACTORY INSTALLED).

1 2 3

EARD-6

M23578

POWER-CLOSED/

SPRING-OPEN

ZD DAMPER

POWER-CLOSED/

SPRING-OPEN

ZD DAMPER

POWER-CLOSED/

SPRING-OPEN

ARD DAMPER

VISIONPRO IAQ

C7835A DISCHARGE

AIR SENSOR

VISIONPRO IAQ

VISIONPRO IAQ

Summary of Contents for TrueZONE ARD Series

Page 1: ...Male crimped and female uncrimped ends to connect to any rigid or flexible round duct Rated to operate up to 1 in wc Blade closes off tightly against gasket for minimal leakage Fail safe normally open operation Simple easy to wire two wire installation with a third wire option M4 for LED open only light EARD Features Adjustable open position range stops Shipped as power open spring return closed d...

Page 2: ...eans Direct connection to damper shaft Motor Mounting Position Multi poise Motor Dimensions See Fig 1 Construction ARD Dampers Frame Galvanized steel spiral duct crimped on down stream side ARD Sizes 5 in 6 in 7 in 8 in 9 in 10 in 12 in 14 in 16 in 18 in and 20 in diameters Gauge ARD5 ARD12 24 Gauge frame and 22 Gauge Blade ARD14 ARD20 22 Gauge frame and 20 Gauge Blade EARD Dampers Frame Galvanize...

Page 3: ...r checkout and maintenance The ZD comes complete and ready for installation The motor and linkage are factory assembled to the damper The damper is assembled for installation and wiring to the control panel Selecting Damper Size To ensure correct operation be sure to select the correct zone damper size for the air duct IMPORTANT Be aware that damper sizes are built 5 32 in smaller than the listed ...

Page 4: ... set screw pointing toward the open position on the label 5 Attach new motor to the coupling be sure the standoff on motor is positioned in the grommet on the faceplate and the set screw is aligned with the motor shaft hole 6 Tighten the set screw Wiring a Single ARD Power Closed to a Control Panel Fig 3 ARD configured as power closed Checkout CAUTION Possible Equipment Damage Do not manually open...

Page 5: ... G AT120 W8150A EARD 6 HVAC W C RC Y G G RC CC CH W G TH8110U R C DAMPER AUX REMOTE M23547 M23591 HVAC W C R Y G VISIONPRO TH9000 THERMOSTAT H U M D H M V N T OR 1 2 3 C R RC RH 24 VAC COMMUNICATION TERMINALS COMMUNICATION LED W1 W2 W3 Y Y2 G O B AUX AUX2 Y Y2 G CONV HP L NOT USED 1 2 1 2 SYSTEM MONITOR NOT USED OUTDOOR TEMP SENSOR INDOOR TEMP SENSOR DISCHARGE AIR TEMP SENSOR 1 2 D A T S O U T I N...

Page 6: ...TABLE 1 0 3 ENVIRACOM FURN NO YES 4 PURGE TIME 2 MIN 3 5 MIN 5 PURGE FAN HVAC PANEL 6 PURGE DAMPER NO CHG OPEN 7 COMP STAGES 1 2 8 HEAT FAN HVAC PANEL 9 HP CHANGEOVER O B 10 UNUSED O N 1 2 3 4 5 6 7 8 9 10 1 2 CONV HT STG 1 1 1 1 0 2 0 1 3 0 0 HP 24 VOLT 40 VA TRANSFORMER R C L1 L2 R W1 W2 Y1 Y2 G C DOTTED LINES FOR 2 STAGE APPLICATIONS SINGLE TRANSFORMER HEATING COOLING SYSTEMS REQUIRE A JUMPER T...

Page 7: ...hat requires 24V to the two motor leads to power the damper closed When power is removed from the motor the damper springs back to its normally open position When used with Honeywell Networked Zoning use closed and com terminals Fig 7 Power closed spring return open ZD wiring Wiring Multiple Dampers When the same zone controls two or more dampers wire the dampers in parallel to terminals M1 and M6...

Page 8: ...RS Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 customer honeywell com U S Registered Trademark 2015 Honeywell International Inc 33 00040 01 M S 02 15 Printed in United States ...

Reviews: