1. TMS
9250 Torque Measurement System
008-0738-00
Rev B
TMS 9250 Product User Manual
15
April 2012
© 2012 – Honeywell International Inc. All rights reserved
1.5 Installation and Setup
Bolting Information
Tighten all bolts, in incremental steps, to the bolt manufacturer’s rated torque specification.
Use the respective sequence illustration shown in Figure 1 depending on the number of bolts
the sensor requires. This bolting sequence applies to both bolt circles of the torque sensor.
Typical connection schematic of the product for any torque measurement is as shown in
Figure 2. General guidelines shall be considered for mounting the sensor as shown in Figure
3. Outline dimension details for standard models are indicated in Figure 4 to Figure 9; contact
factory for other configurations.
Figure 1: Bolting Pattern for Flange Model
Torque Sensor
Honeywell's TMS 9250 series torque sensors may be operated horizontally, vertically, or at
any angle in between, provided the load is applied through the loading axis. All torque sensors
in this series have bolt patterns that mate directly to standard DIN companion flanges. When
mounted, one of the flanges should be mated to a good quality double flex coupling or a
driveshaft arrangement that incorporates universal joints at each end. This is designed to
compensate for angular and parallel misalignment. Avoid applications that place extraneous
loads on the torque sensor.
sunpower
SPM
CCM
Power
Supply
Belden Tri-axial RF cable
Plug Top
DC Cable
To SPM
RS 232 Cable For
Computer Interface
Analog V
/mA
Output
Frequency
Output
Rotor