background image

TL8230A1003

7

Configuration switches are on the back of the faceplate.

Set the configuration switches

#

Configurations

Up

Down

1

Display format

°F / 12 h

°C / 24 h

2

Early Start

1

1. Early Start is used in Automatic mode only. When Early Start is enabled (on), the thermostat 

determines when to start heating so the Comfort temperature is attained at the beginning of 
periods 1 and 3. When Early Start is disabled (off), heating starts only at the beginning of 
periods 1 and 3; thus there is a delay before the Comfort temperature is reached.

Enable

Disable

3

Not used

69-1803ES-03.book  Page 7  Friday, March 1, 2013  10:13 AM

Summary of Contents for TL8230A1003

Page 1: ...Owner s Guide TL8230A1003 7 Day Programmable Thermostat 69 1803ES 03 book Page 1 Friday March 1 2013 10 13 AM ...

Page 2: ...nd day 8 Daylight Saving Time 9 Preset temperatures 10 Default schedule 11 Modifying the schedule 12 Operation Running the schedule Automatic mode 13 Temporary override of schedule 13 Permanent override Manual mode 14 Appendices Error messages 15 Technical specifications 16 Warranty 17 Customer assistance 18 Table of contents 69 1803ES 03 book Page 0 Friday March 1 2013 10 13 AM ...

Page 3: ... rain Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimney or stove pipes For a new installation choose a location about 5 ft 1 5 m above the floor Install the thermostat on an inside wall facing the heating system Install the thermostat onto an electrical box Use special CO ALR solderless connectors if you connect...

Page 4: ...at can be connected to an electric heater to control the room temperature Supplied Parts One 1 thermostat Two 2 mounting screws Four 4 solderless connectors for copper wires About your thermostat 69 1803ES 03 book Page 2 Friday March 1 2013 10 13 AM ...

Page 5: ...ns see page 10 Backlight button Program clear button Hour button Minutes button Place at Off to cut power to the heater e g in the summer This will not affect the time and temperature settings When the backlight button or either of the buttons is pressed the display illuminates for 12 seconds 69 1803ES 03 book Page 3 Friday March 1 2013 10 13 AM ...

Page 6: ...tes this thermostat model is used to control the ambient temperature Day The thermostat normally displays the actual measured temperature To view the setpoint temperature briefly press either of the buttons The setpoint will appear for 5 seconds To change the setpoint temperature press one of the buttons until the desired temperature is displayed To scroll faster press and hold the button 69 1803E...

Page 7: ...r supply see page 6 4 Install the wallplate to the electrical box using the provided screws 5 Set the configuration switches on the back of the faceplate see page 7 6 Install the faceplate back on the wallplate and tighten the screw If there is a sticker on the screen peel it off 7 Return power to the heating system at the main electrical panel Installing the thermostat Wallplate Faceplate 69 1803...

Page 8: ...Owner s Guide 6 NOTE Connect the wires using the provided solderless connectors for copper wires Wiring diagram Power Load 69 1803ES 03 book Page 6 Friday March 1 2013 10 13 AM ...

Page 9: ...atic mode only When Early Start is enabled on the thermostat determines when to start heating so the Comfort temperature is attained at the beginning of periods 1 and 3 When Early Start is disabled off heating starts only at the beginning of periods 1 and 3 thus there is a delay before the Comfort temperature is reached Enable Disable 3 Not used 69 1803ES 03 book Page 7 Friday March 1 2013 10 13 A...

Page 10: ...utton to set the minutes 3 Press the Day button to set the day 4 Press the Mode Ret button to return the thermostat to normal display NOTE The thermostat will automatically return to normal display if no button is pressed for 60 seconds Time and day 69 1803ES 03 book Page 8 Friday March 1 2013 10 13 AM ...

Page 11: ... the buttons to toggle between On enabled and Off disabled 3 Press the Day button briefly The year setting is displayed 4 Press either of the buttons to set the current year 5 Press the Day button briefly The month setting is displayed 6 Press either of the buttons to set the current month 7 Press the Day button briefly The date setting is displayed 8 Press either of the buttons to set the current...

Page 12: ...con will appear on the screen To modify a preset temperature 1 Press one of the buttons to display the desired temperature 2 Press and hold the appropriate preset temperature button or until its icon is displayed Preset temperatures Preset temperature Intended use Icon Default setting Comfort When at home 70 F 21 C Economy When asleep or away from home 62 F 16 5 C Vacation During prolonged absence...

Page 13: ...mbinations 1 and 4 or 2 and 3 Early Start see page 9 will not work with any other combinations You can have a different program every day i e each period can start at a different time every day The thermostat has been programmed with the following schedule Default schedule Period Description Setting MO TU WE TH FR SA SU Wake Comfort 6 00 AM 6 00 AM 6 00 AM 6 00 AM 6 00 AM 6 00 AM 6 00 AM Leave Eco...

Page 14: ...e entire week 4 Press Hour and Min to set the period start time or press Clear to skip cancel the period will be displayed 5 Repeat steps 2 to 4 to program another period 6 Press Mode Ret to return the thermostat to normal display NOTE The thermostat will automatically return to normal display if no button is pressed for 60 seconds Modifying the schedule 69 1803ES 03 book Page 12 Friday March 1 20...

Page 15: ...e setpoint temperature by pressing the or button when the thermostat is in Automatic mode the new temperature will be used until the beginning of the next period flashes during the temporary override You can cancel the temporary override by pressing Mode Ret Running the schedule Automatic mode Temporary override of schedule 69 1803ES 03 book Page 13 Friday March 1 2013 10 13 AM ...

Page 16: ...mode press Mode Ret to display on the screen In this mode the thermostat does not follow the programmed schedule Press the or button to set the temperature Permanent override of schedule Manual mode 69 1803ES 03 book Page 14 Friday March 1 2013 10 13 AM ...

Page 17: ...below the display range Heating is activated The measured temperature is above the display range Heating is deactivated Verify the thermostat connection and sensor connection Error Messages 69 1803ES 03 book Page 15 Friday March 1 2013 10 13 AM ...

Page 18: ... 32 F to 158 F 0 C to 70 C Resolution 1 F 0 5 C Data protection In the event of a power failure most settings are saved However the time and Daylight Saving Time must be set if the power failure lasts more than 6 hours The thermostat will return to the mode that was active prior to the power failure Technical Specifications 69 1803ES 03 book Page 16 Friday March 1 2013 10 13 AM ...

Page 19: ...in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDI RECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow th...

Page 20: ...out the operation of your thermostat please go to www honeywell com yourhome or call Honeywell Customer Care toll free at 1 800 468 1502 Printed in USA 69 1803ES 03 03 2013 Customer assistance 69 1803ES 03 book Page 18 Friday March 1 2013 10 13 AM ...

Page 21: ...Guía para el usuario TL8230A1003 Termostato que se programa por 7 días 69 1803ES 03 book Page 1 Friday March 1 2013 10 13 AM ...

Page 22: ...ración Hora y día 8 Horario de verano 9 Temperaturas predefinidas 10 Horario de fábrica 11 Modificación del horario 12 Funcionamiento Uso del horario Modo Automático 13 Cancelación temporaria del horario 13 Cancelación permanente Modo Manual 14 Anexos Mensajes de error 15 Especificaciones técnicas 16 Garantía 17 Assistencia al cliente 18 Índice 69 1803ES 03 book Page 0 Friday March 1 2013 10 13 AM...

Page 23: ...to al agua o a la lluvia Deben evitarse los sitios en los haya corrientes de aire arriba de una escalera de una salida de aire los puntos en los que el aire no circule detrás de una puerta los rayos directos del sol los conductos disimulados o las chimeneas En el caso de una nueva instalación colocar el termostato a alrededor de 5 pies 1 5 m sobre el nivel del piso Instalar el termostato en una ca...

Page 24: ...tarse a un calentador eléctrico destinado a controlar la temperatura de la habitación Partes provistas Un 1 termostato Dos 2 tornillos de montaje Cuatro 4 conectores sin soldadura para cables de cobre Sobre el termostato 69 1803ES 03 book Page 2 Friday March 1 2013 10 13 AM ...

Page 25: ...na 10 Botón de retroiluminación Anulación Ajuste de la hora Ajuste de los minutos Poner el conmutador en Off para apagar el aparato Esto no afectará los ajustes de hora y temperatura Cuando se presiona el botón de retroiluminación o uno de los botones la pantalla se ilumina durante 12 segundos Conmutador On Off encendido apagado 69 1803ES 03 book Page 3 Friday March 1 2013 10 13 AM ...

Page 26: ...ato se usa para controlar la temperatura ambiente Día El termostato indica normalmente la temperatura real medida Para ver la temperatura del punto de ajuste presionar brevemente uno de los botones El punto de ajuste aparecerá durante 5 segundos Para cambiar la temperatura del punto de ajuste presionar uno de los botones hasta que se visualice la temperatura deseada Para hacer desfi lar más rápido...

Page 27: ...a alimentación ver la página 6 4 Fijar la placa mural a la caja eléctrica con los tornillos provistos 5 Ajustar los conmutadores de configuración que están detrás de la tapa ver la página 7 6 Reponer la tapa sobre la placa mural y ajustar el tornillo Quitar el autoadhesivo de la pantalla si lo hubiera 7 Conectar el sistema de calefacción desde el panel eléctrico principal Instalación del termostat...

Page 28: ...Guía para el usuario 6 NOTA conectar los cables utilizando conectores sin soldadura para cables de cobre Diagramas de conexiones alimentación carga 69 1803ES 03 book Page 6 Friday March 1 2013 10 13 AM ...

Page 29: ... solamente Cuando la función está activada el termostato calcula la hora óptima para encender la calefacción a fin de obtener la temperatura de Confort al comienzo de los períodos 1 y 3 Cuando esta función está desacti vada Off la calefacción se enciende solamente al comienzo de los períodos 1 y 3 por lo que hay una demora antes de que se alcance la temperatura de Confort Activado Desactivado 3 No...

Page 30: ...tón Min para ajustar los minutos 3 Presionar el botón Day para ajustar el día de la semana 4 Presionar el botón Mode Ret para terminar NOTA el termostato volverá automáticamente a la pantalla normal si no se presiona ningún botón durante 60 segundos Hora y el día 69 1803ES 03 book Page 8 Friday March 1 2013 10 13 AM ...

Page 31: ...botones para cambiar entre On función activada y Off función desactivada 3 Presionar el botón Day brevemente y aparecerá el año 4 Presionar cualquiera de los botones para poner el año en curso 5 Presionar el botón Day brevemente y aparecerá el mes 6 Presionar cualquiera de los botones para poner el mes en curso 7 Presionar el botón Day brevemente y aparecerá la fecha 8 Presionar cualquiera de los ...

Page 32: ...Para modificar una temperatura predefinida 1 Presionar uno de los botones para hacer aparecer en pantalla la temperatura deseada 2 Presionar y mantener el botón de temperatura predefinido correspondiente o hasta que su ícono aparezca en pantalla Temperaturas predefinidas Predefinido Uso previsto Ícono valores de fábrica Confort el ocupante está en la casa 70 F 21 C Economía el ocupante está ausent...

Page 33: ...tivará con otras combinaciones Se puede hacer un programa diferente para cada día de la semana es decir cada período puede comenzar a una hora diferente para cada día de la semana El termostato ha sido programado en fábrica con el siguiente horario Horario por defecto Período Descripción Ajuste LU MO MA TU MIE WE JUE TH VIE FR SA SA DO SU Despertar Confort 6 00 AM 6 00 AM 6 00 AM 6 00 AM 6 00 AM 6...

Page 34: ...nar la semana entera 4 Presionar Hour y Min para ajustar la hora de comienzo del período o presionar Clear para saltear cancelar el período aparece 5 Repetir los pasos 2 y 4 para programar otro período 6 Presionar Mode Ret para volver a la pantalla normal NOTA El termostato volverá automáticamente a la pantalla normal si no se presiona ningún botón durante 60 segundos Para modificar el horario 69 ...

Page 35: ...de ajuste de la temperatura presionando el botón o cuando el termostato está en Modo Automático la nueva temperatura se usará hasta el comienzo del período siguiente parpadeará durante la cancelación temporaria Se puede anular la cancelación temporaria presionando el botón Mode Ret Uso del horario Modo Automático Cancelación temporaria 69 1803ES 03 book Page 13 Friday March 1 2013 10 13 AM ...

Page 36: ... presionar Mode Ret para que en la pantalla aparezca En este modo el termostato no sigue el horario programado Presionar los botones o para ajustar la temperatura Cancelación permanente del horario Modo Manual 69 1803ES 03 book Page 14 Friday March 1 2013 10 13 AM ...

Page 37: ...o stato La calefacción está activada La temperatura medida es superior al margen de visualización del termo stato La calefacción está desactivada Verificar las conexiones del termostato y del sensor de temperatura Mensajes de error 69 1803ES 03 book Page 15 Friday March 1 2013 10 13 AM ...

Page 38: ...ción 32 F a 158 F 0 C a 70 C Resolución 1 F 0 5 C Protección de los datos la mayor parte de los datos están salvaguardados en prevención de un corte de corriente Sólo la hora y el horario de verano deben reajustarse si la interrupción de electricidad dura más de 6 horas El termostato volverá al modo en el que estaba antes del corte Especificaciones técnicas 69 1803ES 03 book Page 16 Friday March 1...

Page 39: ...staba en posesión del consumidor La única responsabilidad de Honeywell será la de reparar o reemplazar el producto de acuerdo con los términos aquí establecidos HONEYWELL NO SERA RESPONSABLE DE NINGUNA PERDIDA NI DE NINGUN DAÑO DE NINGUN TIPO INCLUIDOS LOS DAÑOS IMPREVISTOS O DERIVADOS QUE RESULTEN DIRECTA O INDIRECTAMENTE DEL INCUMPLIMIENTO DE CUALQUIER GARANTIA EXPRESA O IMPLICITA O DE CUALQUIER...

Page 40: ...ionamiento del termostato visite http yourhome honeywell com o llame sin cargo al servicio de atención al cliente de Honeywell al 1 800 468 1502 Impreso en EE UU 69 1803ES 03 03 2013 Asistencia al cliente 69 1803ES 03 book Page 18 Friday March 1 2013 10 13 AM ...

Reviews: