Electrical Connections  

Electrical Connections 

The TemaServer is powered at low voltage (12V

AC

) by means of a 

transformer connected to the 115/230V 50/60Hz network switch. This switch 
must be positioned prior to the TemaServer. The cables connecting the 
transformer and the TemaServer must be at least AWG20 and no more than 
10m long (see Figure 2). 

 

 10m max.

115/230V

12V

125mA

black brown

yellow-green

230V 50Hz or
115V 60Hz

transformer
module

GROUND

yellow-green

oragne

gray

I N

O

U

T

 

Figure 2: Electrical connections 

 

Summary of Contents for temaserver TS TA series

Page 1: ...TS TAxx Integrated Interactive Terminals Installation Manual ...

Page 2: ......

Page 3: ...ents 7 INSTALLATION 8 Attaching the Terminal Support Plate 8 Hooking Up the Terminal 9 Connecting the Cables 10 Jumpers 13 Auxiliary Connections 14 Closing the Terminal 15 Applying the Entry Exit Labels 16 TECHNICAL SPECIFICATIONS 17 TemaServer TS TAx3 CTU K03 code 1500064EB 17 Spare Parts 18 TemaServer TS TAx4 CTU K04 code 1500087CA 19 Spare Parts 20 Optional Parts 21 Versione 1 0 US ...

Page 4: ... this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try to correct the interference by one or more the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different fr...

Page 5: ... the box must satisfy the requirements laid down for the mounting area and allow the necessary space for opening the box see Figure 1 In addition there must be sufficient space to the right and rear of the unit to allow access to the box with a screwdriver tube 14cm 12cm mounting area encased box floor cables 32cm work area Figure 1 Space requirements for mounting ...

Page 6: ...z network switch This switch must be positioned prior to the TemaServer The cables connecting the transformer and the TemaServer must be at least AWG20 and no more than 10m long see Figure 2 10m max 115 230V 12V 125mA black brown yellow green 230V 50Hz or 115V 60Hz transformer module GROUND yellow green oragne gray I N O U T Figure 2 Electrical connections ...

Page 7: ...y recommended that you run the LAN cable into a separate tube from the one used for the 12V power cable If you wish to keep the LAN cable and the 12V power cable together make sure that the 12V cable is shielded You must not on any account attempt to route the LAN cable and the primary power cable 230V together encased box tube cables floor 120 cm Figure 3 Cabling arrangements ...

Page 8: ...port plate drill two holes in the wall in which to place the plastic anchors that hold up the support plate see Figure 4 Make sure that the box attached to the wall is aligned with the niche on the lower part of the support plate use a 6mm parallel tip flat head screwdriver anchor anchor Figure 4 Terminal support plate ...

Page 9: ...r part of the terminal to the upper hooks on the support plate 2 Insert the cables into the terminal through the specified openings 3 Tighten the two screws that secure the terminal to the support plate use a 6mm parallel tip flat head screwdriver 1 Attach terminal to hooks 3 fasten the screws 2 Insert cables Figure 5 Hooking up the terminal ...

Page 10: ...s as a cable clamp use a 5mm Philips screwdriver Fasten cable clamp board 8 screws Lock cables Figure 6 Connecting the cables 3 Attach the wire pin connectors to the terminals located on the lower part of the terminal unit use a 3mm flat head screwdriver 4 Insert the cable in the corresponding connector see Figure 7 to complete the connection to the LAN Ethernet 10BaseT twisted pair Figure 9 illus...

Page 11: ...BaseT power supply 12V Status LED Power supply fuses Battery fuse F1 Battery cable RESET button JP4 JP3 jumpers Ethernet test JTAG P10 wall tamper jumper P12 connector for production jumper LEAVE OPEN Battery Collision red RUN green Plug in Ethernet I O terminal box TX red RX green Figure 7 Main circuit components orange green yellow grey Figure 8 Close up view of the 12V supply ...

Page 12: ...tmost keys connection with LCD controller lamp cable for rear lighting of LCD jumper JP2 pin1 2 MAG TEK pin 2 3 bidirectiona l serial interface TemaServer mother board connection keyboard cable 4 leftmost keys keyboard cable 6 central keys 4x4 keyboard optional Figure 9 Display board details ...

Page 13: ...o update of firmware Open JP3 Ethernet full duplex Open JP4 Ethernet loopback Inserted Table 1 Configuration of jumpers on main board Configure the jumpers on the display board as specified inTable 2 Jumper Function Default state JP2 data transmission inserted between pins 1 and 2 JP3 data receipt inserted between pins 1 and 2 Table 2 Configuration of jumpers on display board ...

Page 14: ...must be used The cable s shield must be connected to ground connector You can define the operational mode of each relay by positioning the appropriate jumpers as follows Jumper OUT1 between 12 NO for relay 1 normally open Jumper OUT1 between 23 NC for relay 1 normally closed Jumper OUT2 between 12 NO for relay 2 normally open Jumper OUT2 between 23 NC for relay 2 normally closed You can define the...

Page 15: ...ery cable to the battery 2 Make sure that the rubber gasket is correctly positioned 3 Close the terminal cover by rotating it 4 Fasten the cover with the two special screws see Figure 11 located on the side of the terminal use a TORX anti tamper TX10 screwdriver Fasten the special screws IN O U T Figure 11 Closing the terminal ...

Page 16: ...ls to the magnetic reader according to the pre configured transit direction Make sure that you place the labels in the appropriate hollows TS Tax3 TS Tax4 see details in Figure 12 and Figure 13 I N O U T ß EXIT ENTRY à Figure 12 Entry exit labels O U T I N ß ENTRY EXIT à Figure 13 Entry exit labels ...

Page 17: ...ly via TRN01 Transformer 230VAC 15 50Hz 30mA nominal 7VA 40mA max for fast battery recharge Weight including frame 3 5kg transformer TRN01 500g Size 220x305x80 mm IP Protection Rating IP55 Environmental temperature for correct operation 0 50 C LAN Ethernet connection 10BaseT standard cable on RJ45 Proxy antennae Double antenna 125KHz for HID cards Read distance 0 50mm Expansions 2 slots for 1 unit...

Page 18: ...elf powered mode dry contacts open contact 2Kohm closed contact 100 ohm 10mA Regulations compliance Directive EMC 89 336 EEC 92 31 EEC Directive Low Voltage 72 23 EEC 93 68 EEC EN60950 EN55024 EN55022 EN61000 3 2 3 EN 300 330 Includes a part with FCC ID HS9 CTU K03 Spare Parts Fuses F1 2A 250V delayed F2 1A 250V delayed F3 1A 250V delayed Battery 6V 1 2 Ah code 1801026 Figure 14 TemaServer TS TAx3...

Page 19: ...N01 Transformer 230VAC 15 50Hz 30mA nominal 7VA 40mA max for fast battery recharge Weight including frame 3 5kg transformer TRN01 500g Size 220x305x80 mm IP Protection Rating IP55 Environmental temperature for correct operation 0 50 C LAN Ethernet connection 10BaseT standard cable on RJ45 Proxy antenna Antenna 139KHz for WSE cards Read distance 0 30mm Expansions 2 slots for 1 unit plug in cards or...

Page 20: ...self powered mode dry contacts open contact 2Kohm closed contact 100 ohm 10mA Regulations compliance Directive EMC 89 336 EEC 92 31 EEC Directive Low Voltage 72 23 EEC 93 68 EEC EN60950 EN55024 EN55022 EN61000 3 2 3 EN 300 330 Includes a part with FCC ID C4P DR4201 Spare Parts Fuses F1 2A 250V delayed F2 1A 250V delayed F3 1A 250V delayed Battery 6V 1 2 Ah code 1801026 Figure 15 TemaServer TS TAx4...

Page 21: ...Optional Parts Page 21 Optional Parts TORX TX10 screwdriver Code 1500108AA ...

Page 22: ......

Page 23: ...Internet http www temaline com ...

Reviews: