background image

T87F THERMOSTATS

3

60-2222—3

Accessories:

Q539 Subbases—provide system and fan switching and cool-

ing anticipation (unless otherwise specified) for T87F heat-

ing, cooling and heating-cooling thermostats.

TG587F1008 Thermostat Guard Key Lock Cover with window.

TG587F1016 Thermostat Guard Key Lock cover without 

window.

104456B Two terminal heat only T87 Wallplate.

137421AE-T87 Taupe Wallplate with positive Off.

137421K-T87 Taupe Wallplate without positive Off.

137421R-T87 White Wallplate.

198170A Designer Beige Adapter Kit.

198172 Cover Ring for T87 Designer Beige models.

199933 Cover Ring for Taupe T87 models.

114855-00029 Cover Ring for Gold T87 models.

137421A-T87 Gold Wallplate without positive Off.

137421B-T87 Gold Wallplate with positive Off.

221886A Easy-to-Use™ Clear Ring. Durable plastic ring 

snaps on Easy-to-See models.

202687A Premier White® Adapter Kit includes 6 in. cover 

assembly and adapter ring to mount on outlet box or cover 

marks from old thermostats.

32005439-001 Taupe Adapter Kit includes 6 in. cover assem-

bly and adapter ring to mount on outlet box or cover marks 

from old thermostat.

MERCURY NOTICE

If this control is replacing a control that contains 

mercury in a sealed tube, do not place your old control 

in the trash. Dispose of properly.

Contact your local waste management authority for 

instructions regarding recycling and the proper 

disposal of an old control.

INSTALLATION

CAUTION

Voltage Hazard.

Can cause electrical shock or equipment damage.

Disconnect power before beginning installation.

CAUTION

Equipment Damage Hazard.

Improper installation can burn out thermostat heat 

anticipator.

On systems using a low voltage gas valve, 

do not 

apply a jumper across the valve coil terminals.

When Installing this Product. . .

1.

Read these instructions carefully. Failure to follow them 

could cause a hazardous condition.

2.

Check the ratings given in the instructions and on the 

product to make sure the product is suitable for your 

application.

3.

Installer must be a trained experienced service techni-

cian.

4.

After installation is complete, check out product opera-

tion as provided in these instructions.

Location

Locate the thermostat about 5 ft (1.5m) above the floor in an 

area with good air circulation at average temperature.

Do not install the thermostat where it can be affected by:

— drafts, or dead spots behind doors and in corners.

— hot or cold air from ducts.

— radiant heat from sun or appliances.

— concealed pipes and chimneys.

— unheated (uncooled) areas such as an outside wall behind 

the thermostat.

This thermostat is a precision instrument and was carefully 

adjusted at the factory. 

Handle it carefully.

Mount Wallplate or Subbase

IMPORTANT

Use a spirit level to accurately level the wallplate or 

subbase as shown in Fig. 1. Inaccurate leveling may 

cause the thermostat to deviate from setpoint.

When using the T87F with a Q539 Subbase, follow 

the mounting and wiring instructions for the subbase.

Use the cover ring (if desired), adapter plate (if needed), 

wallplate or subbase, T87F and screws as shown in Fig. 2 and 

3.

IMPORTANT

Before mounting the thermostat, see Setting and 

Checkout section, Heat Anticipator Adjustment sub-

section.

1.

Place the cover ring on the wall at the desired location 

with the cable entrance holes to the left. 

NOTE: If an outlet box is used, place the cable entrance 

holes toward the bottom. The side showing 

MADE IN 

U.S.A.

 must be against the wall.

2.

Pull the thermostat cable through the entrance hole of 

the cover ring and the entrance hole of the wallplate or 

subbase and adapter plate (if used).

3.

Fasten the cover ring, adapter plate (if used), and the 

wallplate or subbase.

4.

Level the wallplate as shown in Fig. 1 and tighten the 

screws.

5.

After wiring the subbase or wallplate, plug the hole to 

prevent interior wall drafts from affecting the thermostat.

6.

Align the thermostat over the wallplate and tighten the 

three captive mounting screws.

Summary of Contents for T87F Series

Page 1: ...es cooling anticipation The Q539 Subbase may be added for system and fan switching The Q539 Subbase also provides cooling anticipation FEATURES For 24 Vac to 30 Vac control of heating or cooling systems Thermostat cover ring may be painted to match room decor Knurled dial provides easy setpoint adjustment Separate temperature setting and thermometer scale located on face of thermostat T87F distinc...

Page 2: ...wire spst heating or cooling 3 wire spdt heating cooling or 3 wire spdt series 20 heating systems Additional Tradeline Features Cover ring included for covering old thermostat marks or for mounting T87F on outlet box 137421 Wallplate extends beyond thermostat for trim appear ance 198170A Wallplate for Designer Models Tradeline pack with cross reference label and special instruction sheet Standard ...

Page 3: ...2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service techni cian 4 After installation is complete check out product opera tion as provided in these instructions Location Locate the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperat...

Page 4: ...ms represent typical applications SPIRIT LEVEL LEVELING POSTS 2 MOUNTING SLOTS SPIRIT LEVEL 104456B WALLPLATE 137421A B D WALLPLATE MOUNTING SLOTS BE SURE WALL HOLE IS PLUGGED MOUNTING SLOTS TERMINAL SCREWS M20772 OPENING FOR THERMOSTAT WIRING T87F THERMOSTAT COVER RING M20773 THERMOSTAT COVER RING MOUNTING SLOTS 4 THERMOSTAT CABLE OPENING 104456B WALLPLATE OUTLET BOX 127293 COVER RING Q539 SUBBAS...

Page 5: ...E COOLING ANTICIPATOR TO SYSTEM CONNECTIONS COOLING ONLY THERMOSTAT MODEL WITH POSITIVE OFF SWITCH OPENS THE THERMOSTAT CIRCUIT WHEN SETPOINT DIAL IS MOVED TO THE OFF POSITION MAKE SYSTEM WIRING CONNECTIONS TO TERMINALS ON 137421D WALLPLATE R1 W1 TERMINALS ON THERMOSTAT ARE DIRECTLY CONNECTED TO R Y TERMINALS ON WALLPLATE WHEN THERMOSTAT IS MOUNTED ON WALLPLATE M20775 TEMPERATURE FALL ADJUSTABLE H...

Page 6: ...ust be used A three wire open contact high limit control requires a jumper as shown in Fig 12 Fig 11 T87F replacing a series 10 thermostat connected to a 2 or 3 wire low limit control L2 COMBINATION FAN AND LIMIT CONTROL FAN MOTOR BURNER MOTOR THERMOSTAT Y R W CAD CELL 1 2 3 R8184G WHITE ORANGE BLACK IGNITION OIL VALVE POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED R8184...

Page 7: ...Adjustment The thermostat has an adjustable heat anticipator that must be set on the number that corresponds to the current rating of the primary control of the system for example gas valve oil primary Fig 14 T87F interior detail Fig 15 Adjust heat anticipator to match current rating of primary control Series 20 Thermostat T87F Thermostat R R B W W Y LOW LIMIT OPERATING CONTROL T87F SERIES 10 OPEN...

Page 8: ...tting until the cooling equipment starts 6 Raise the setting above the room temperature and the cooling system should shut down 7 Make certain that the equipment functions properly in response to the thermostat RECALIBRATION IMPORTANT If the thermostat scaleplate moves pointer is station ary when setting the temperature the thermostat is a Group I model If the scaleplate is stationary and the poin...

Reviews: