Honeywell T834C Quick Start Manual Download Page 2

T834C, T8034C HEATING/COOLING THERMOSTATS

68-0075-2

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 

TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 

phone:

1.

Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).

2.

Honeywell Customer Care

1885 Douglas Drive North

Minneapolis, Minnesota 55422-4386

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.

International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 

Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

The specifications given in this publication do not include 

normal manufacturing tolerances. Therefore, this unit may not 

exactly match the listed specifications. Also, this product is 

tested and calibrated under closely controlled conditions, and 

some minor differences in performance can be expected if 

those conditions are changed.

SUPER TRADELINE®/TRADELINE® 

MODELS

SUPER TRADELINE®/TRADELINE® models are selected 

and packaged for ease of handling, ease of stocking, and 

maximum replacement value. SUPER TRADELINE®/

TRADELINE® models specifications are the same as those of 

standard models except as follows:

SUPERTRADELINE® Models:

T843C Heating-Cooling Thermostat for use in gas-fired, oil-

fired, or central electric heat and standard cooling systems; 

mounts vertically; adjustable heat anticipator—0.18 to 

1.0A.

T8034C Heating-Cooling Thermostat for use in gas-fired, oil-

fired or central electric heat and standard cooling systems; 

mounts horizontally; adjustable heat anticipator—0.18 to 

1.0A.

Additional SUPERTRADELINE® Features:

• Fan can be controlled from thermostat or plenum switch.

• Wallplate for covering marks from old thermostat (T8034C 

only).

TRADELINE® Models:

T843C Heating-Cooling Thermostat for use in single-stage 

heat pump, electric furnace and standard heating-cooling 

systems; mounts vertically; adjustable heat anticipator—

0.18 to 1.0A. Model available with °C scaleplate.

T8034C Heating-Cooling Thermostat for use in standard heat-

ing-cooling systems; mounts horizontally; adjustable heat 

anticipator—0.18 to 1.0A. Model available with °C scale-

plate and isolated heat-cool circuits for systems with sepa-

rate heating and cooling transformers.

STANDARD MODELS

Standard Models:

T834C Heating-Cooling Thermostat for use in standard heat-

ing-cooling systems. Single-stage heat pump, electric heat 

and dual fuel models also available. Mounts vertically. Pro-

vides Heat-Off-Cool System switching and Auto-On or On-

Auto Fan switching (specify when ordering).

T8034C Heating-Cooling Thermostat for use in standard heat-

ing-cooling systems; mounts horizontally. Provides Heat-

Off-Cool System switching and On-Auto Fan switching. 

Canadian model available with °C scaleplate, and isolated 

heat-cool circuits for systems with separate heating and 

cooling transformers.

Electrical Ratings: 

Heating: 0.18 to 1.0A at 30 Vac maximum; (0.3 to 1.2A 

optional).

Cooling: 1.5A running, 7.5A inrush at 25 Vac.

Heat Anticipator: Adjustable 0.18 to 1.0A , 0.3 to 1.2A (specify 

when ordering).

Cooling Anticipator: Fixed, 24 to 30 Vac.

Switching:

Heating: Spdt mercury switch makes R to W on temperature 

fall.

Cooling Thermostats: Spdt mercury switch makes R to Y on 

temperature rise.

Temperature Setting Range (Specify When Ordering):

55° F to 95°F (13°C to 35 °C).

10°C to 30°C (50°F to 86°F).

Dimensions:  

See Fig. 1 and 2.

Mounting Means: 

Two screws through base to wall or 

2 x 4 in. outlet box. T834 fits on vertical outlet box; T8034 

fits on horizontal outlet box.

Summary of Contents for T834C

Page 1: ...ed bimetal operates silent dust free spdt mercury switch T834C models have vented cover to provide better air flow for temperature sensing Adjustable heat anticipator and fixed cool anticipator on all models T834C models mount directly on wall or on a vertical outlet box T8034C models mount directly on wall or on a horizontal outlet box SUPER TRADELINE T8034C includes horizontal wallplate for cove...

Page 2: ...rd cooling systems mounts horizontally adjustable heat anticipator 0 18 to 1 0A Additional SUPERTRADELINE Features Fan can be controlled from thermostat or plenum switch Wallplate for covering marks from old thermostat T8034C only TRADELINE Models T843C Heating Cooling Thermostat for use in single stage heat pump electric furnace and standard heating cooling systems mounts vertically adjustable he...

Page 3: ... the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Hazard Can cause personal electrical shock or equipment da...

Page 4: ...he thermostat and mounting plate if used to the wall or outlet box with a screw through the top mounting hole Adjust thermostat so it is approxi mately level and start the second screw through the bottom mounting hole Do not tighten 8 Level the thermostat exactly using a level device Tighten the mounting screws IMPORTANT This thermostat is calibrated at the factory mounted at true level Any inaccu...

Page 5: ...le to the wall or outlet box with a screw through the left mounting hole Adjust thermostat so it is approximately level and start the second screw through the right mounting hole Do not tighten 8 Level the thermostat exactly using a level device Tighten the mounting screws IMPORTANT This thermostat is calibrated at the factory mounted at true level Any inaccuracy in leveling during the mounting ca...

Page 6: ...SYSTEM SWITCH HEAT OFF COOL FAN SWITCH AUTO ON H1 TEMP FALL C1 ANTICIPATOR FAN RELAY HEAT OFF COOL C1 H1 ANTICIPATOR G R Y L1 HOT L2 W HEAT RELAY 1 1 H1 TEMP FALL C1 L1 HOT L2 1 1 2 2 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED INSTALL JUMPER BETWEEN W AND Y TERMINALS WHEN HEAT RELAY IS NOT USED HEAT RELAY FAN RELAY FAN SWITCH ON AUTO COOL OFF HEAT COOL OFF HEAT SYSTE...

Page 7: ...urrent draw of the primary control Use this thermostat only on systems with current draws that fall within the range of the heat anticipa tor do not use this device on Powerpile millivolt systems 1 A current rating is usually stamped in the nameplate of the primary control Set the adjustable heat anticipator indicator to match the value given on the nameplate 2 If the current rating is not availab...

Page 8: ...iately 3 Move temperature setting lever about 10 F 6 C above room temperature Cooling and fan should shut off Fan 1 With System switch set to Off and Fan switch set to On the fan runs continuously 2 Move Fan switch to Auto In gas fired or oil fired sys tems fan operation is controlled by thermostat in cool ing and by plenum fan control in heating In heat pump and some central electric heat systems...