5895XL Manual - P/N 151142-L8:L 08/09/2017
1
Content
1.1: Maximum Number of SBUS Modules ..............................................................................................................................................................2
1.2: Agency Requirements ........................................................................................................................................................................................4
2.1: Inventory............................................................................................................................................................................................................6
2.2: Environmental Specifications ............................................................................................................................................................................6
2.3: Software Downloads..........................................................................................................................................................................................6
2.4: 5895XL Board and Terminal Strip Description.................................................................................................................................................7
2.5: Earth Fault Resistance .......................................................................................................................................................................................8
2.6: Calculating Current Draw and Standby Battery ................................................................................................................................................9
2.6.2: Current Draw Worksheet ........................................................................................................................................................................9
2.6.3: Current Draw Worksheet for SD SLC Devices ....................................................................................................................................12
2.7.1: Length Limitations................................................................................................................................................................................15
2.7.2: Calculating Wiring distance for SBUS modules ..................................................................................................................................15
2.7.3: Wire Routing ........................................................................................................................................................................................17
3.1: AC Power.........................................................................................................................................................................................................18
3.2: Battery Connection ..........................................................................................................................................................................................18
3.3: Connecting the 5895XL to the FACP ..............................................................................................................................................................19
3.4: Connecting SBUS Modules to the 5895XL.....................................................................................................................................................21
3.5: Flexputs™ I/O Circuits....................................................................................................................................................................................22
3.5.1: Conventional Notification Appliance ...................................................................................................................................................22
3.5.2: Releasing Operations ............................................................................................................................................................................23
3.5.4: Installing 2-Wire Smoke Detectors ......................................................................................................................................................25
3.5.5: Installing 4-Wire Smoke Detectors ......................................................................................................................................................26
3.5.6: Auxiliary Power Configuration ............................................................................................................................................................27
3.6: Conventional Relay Installation ......................................................................................................................................................................28
A.7: Notification Appliances ..................................................................................................................................................................................30
A.8: Two-Wire Smoke Detectors ............................................................................................................................................................................38
A.9: Four-Wire Smoke Detectors/Devices (UL Listed)..........................................................................................................................................40
A.10: Door Holders (UL Listed).............................................................................................................................................................................42
A.11: Relays (UL Listed) ........................................................................................................................................................................................42
A.12: Compatible 520Hz Signaling Speakers ........................................................................................................................................................43
A.13: Compatible 520Hz Low Frequency Bases....................................................................................................................................................43
Honeywell Fire Product Warranty and Return Policy
Manufacturer Warranties and Limitation of Liability
Summary of Contents for Silent knight 5895XL
Page 47: ......