9.4. Cleaning
If necessary, the filter bowl and the filter can be cleaned.
1. Close shutoff valve on inlet
2. Release pressure on outlet side (e.g. through water tap)
3. Close shutoff valve on outlet
4. Unscrew filter bowl
• Use double ring wrench ZR06K
5. Remove filter, clean and reinsert
6. Place O-ring onto filter bowl
7. Screw in filter cup hand-tight (up to max. 18Nm)
8. Slowly open shutoff valve on inlet
9. Slowly open shutoff valve on outlet
10. Disposal
• Dezincification resistant brass housing
• Brass threaded connections
• Stainless steel filter mesh on pressure reducing valve
• Transparent synthetic material filter bowl on pressure redu-
cing valve
• High grade synthetic material pressure reducing valve
insert, spring bonnet with adjuster knob, shutoff valves, test
socket, check valve, safety valve insert and drain connector
• Fibre-reinforced NBR diaphragm
• NBR seals
Caution !
Do not use any cleansers that contain solvents and/or
alcohol for cleaning the plastic parts, because this
can cause damage to the plastic components - water
damage could result.
To be carried out by an installation company or the
operator.
Detergents must not be allowed to enter the environ-
ment or the sewerage system!
Observe the local requirements regarding correct
waste recycling/disposal!
11. Troubleshooting
Problem
Cause
Remedy
SG160S and SG160SD
Drips
During the heating up of the water heater no error, normal function
Continually drips from soiling
Actuate lifting grip multiple times so that dirt
particles are flushed out, or replace as neces-
sary
Check valve does not close off
tightly in the front pressure area
Pressure increase in the front pres-sure
area
Replace check valve
Seal surfaces dirty or worn
Replace check valve
Too little or no water pressure
Cut-off fixtures before or after the safety
group not opened entirely
Open the shutoff valves fully
Safety group not installed in the flow
direction
Install safety group in flow direction (observe
arrow direction on housing)
SG160SD only
Water is escaping from the spring
bonnet
Diaphragm in valve insert is faulty
Replace valve insert
Too little or no water pressure
Pressure reducing valve is not set to the
desired outlet pressure
Set outlet pressure
Filter in pressure reducing valve is conta-
minated
Clean or replace filter
The outlet pressure set does not
remain constant
Filter in pressure reducing valve is conta-
minated or worn
Clean or replace filter
Valve insert, sealing ring or edge of
nozzle is contaminated or worn
Replace valve insert
Rising pressure on outlet (e.g. in boiler) Check check valve, safety group etc.
Expansion water from the hot water puri-
fier
Inspect ckeck valve before the hot water purifier
and single-lever mixing valve if necessary
Close shut-off valves to the hot water puri-fier
supply line. Open hot water tap connec-tion.
Does pressure remain constant? Expansion
water of the hot water purifier. Does pressure
increase? Pressure reducer defect