background image

5. Using Camera 
 

48 

ScanPal EDA50 Enterprise Hybrid Device User Guide 

 
 
 
 
 

5 Using 

Camera 

 

This chapter describes how to use a color camera to take photos and videos. 

 

 

Summary of Contents for ScanPal EDA50

Page 1: ...ScanPal EDA50 Enterprise Hybrid Device User Guide i ScanPal EDA50 Enterprise Hybrid Device Model EDA50 011 EDA50 111 Android 4 4 OS version User Guide ...

Page 2: ...ble for the softwares or hardwares selected or used in order to achieve the desired results The proprietary information contained in this article is protected by copyright All rights reserved Without prior written consent from HII any form of photocopy copy or translation into other languages is not allowed Trademark Rights Android Google and other marks are trademarks of Google Inc The Bluetooth ...

Page 3: ...6 Unlocking the screen 16 Scanning Indicator 17 Setting screen backlight 18 Audio features 18 Adjusting the ringtone volume for calls and messages 18 Enabling vibration mode 20 Audio settings 21 Inserting SD card 22 File transfer 23 How to view files on EDA50 23 EDA50 s accessories 24 2 User interface and applications 25 User interface 26 The main interface 26 Navigation and function keys 27 Statu...

Page 4: ...ommunication Function 45 Activating UMTS calls 45 Making a call 46 Answering a call 47 Switching applications during a call 47 Making an emergency call 47 Configuring call settings 47 5 Using Camera 48 Color camera 49 Adjusting camera and video settings 49 Zooming 49 Changing camera settings 49 Taking photos 49 Shooting videos 50 Changing video settings 50 6 Terminal configurations 51 Terminal con...

Page 5: ... Communication via serial port and USB 65 Near Field Communication 65 7 Management and maintenance 66 Upgrading system software 67 Upgrading AutoInstall application 67 Upgrading composite key 67 Manually upgrading Recovery Menu 67 Restarting the terminal 68 Terminal resetting 68 Restore factory settings 69 Cleaning the terminal 69 Terminal disinfection 70 8 Specifications 71 Mechanical and environ...

Page 6: ...vi ScanPal EDA50 Enterprise Hybrid Device User Guide ...

Page 7: ...e Product Service and Maintenance Honeywell International Inc provide services for all of its products all over the world via its service centers For information about the site of service centers please visit www honeywellaidc com and select English as preferred language then select Support Contact Support Service and Maintenance Please contact our service center to get RMA Return Material Authori...

Page 8: ...viii ScanPal EDA50 Enterprise Hybrid Device User Guide ...

Page 9: ...rprise Hybrid Device User Guide 1 1 Features of ScanPal EDA50 Enterprise Hybrid Device EDA50 with Android 4 4 operating system will be introduced in this chapter Users can learn something about the main features functions and accessories of this terminal from this chanpter ...

Page 10: ...2 GB dynamic RAM 8GB flash memory Large display with sensitive multi touch screen High performance area imaging features with an ergonomic scan trigger WCDMA GSM wireless WAN communications ensure high speed data transmission and high fidelity sound support for all network technologies IEEE 802 11a b g n Bluetooth 4 0 Near field communication NFC technology for short range wireless data transmissi...

Page 11: ...1 Features of ScanPal EDA50 Enterprise Hybrid Device ScanPal EDA50 Enterprise Hybrid Device User Guide 3 EDA50 front view Power Indicator Scan Indicator Display Function Key Home Key Return Key ...

Page 12: ...ise Hybrid Device 4 ScanPal EDA50 Enterprise Hybrid Device User Guide EDA50 side and bottom view Left Side View Right Side View Power Button Reset Button Scan Button Volume Up Volume Down Scan Button The Bottom Charging Contact USB Cover ...

Page 13: ... Hybrid Device ScanPal EDA50 Enterprise Hybrid Device User Guide 5 EDA50 back view Camera Battery Cover Buckle Handle Battery Cover String Buckle Scan Engine Speaker Battery Cover Safety Lock Battery Cover Buckle Battery Cover Safety Button ...

Page 14: ...f you need to buy a replacable battery please contact regional resellers Warning Improper use of the battery of this terminal can cause a fire or chemical burns Please don t disassemble the battery or heat it to 100 C 212 F or more or incinerate the battery Make sure waste batteries are properly disposed Keep out of reach of the children We recommend users to use Honeywell Li ion battery pack Damg...

Page 15: ... Replacing batteries When the battery power is low you can charge it together with the terminal or replace it with a fully charged battery 1 Save all the files and close all running apps 2 Long press the power key Until the follow interface pop up 3 Tap Turn off 4 EDA will ask whether to turn off tap Yes ...

Page 16: ...l EDA50 Enterprise Hybrid Device User Guide After it s turned off do as the following instructions manually 1 Press down the battery cover safety button to move the lock to the unlock position at right 2 Open the battery cover with the battery cover buckle handle ...

Page 17: ... Hybrid Device ScanPal EDA50 Enterprise Hybrid Device User Guide 9 3 Insert the battery Insert the non connector side first then press the battery down to establish connection between the battery and the phone 4 Press down the battery cover ...

Page 18: ...of the battery The following table only contains several of the icons For detailed information about battery life and power remained please go to Settings Battery Battery icon Icon Status Battery power is 100 full Battery power is 50 full Battery power is too low Replacing the battery right now The terminal has been connected to external power supply for charging Battery failure occurs Please repl...

Page 19: ...er to http developer android com guide topics ui notifiers notifications html Default power indicator description Connect to power supply Indicator status Description No Flashing amber Orange Battery power is less than 15 full No No light Battery power is higher than 15 full Yes Stable amber Orange Battery power is between 0 to 60 full Yes Flashing green Battery power is between 60 to 95 full Yes ...

Page 20: ...perform Default Battery LED settings If you prefer the indicator as message notification application or device management solution notification indicator you need to select No Battery LED settings Default power indicator meanings Connect to power supply Indicator status Description No Flashing red Battery power is less than 15 full No No light Battery power is 15 or more Yes Stable red Battery pow...

Page 21: ...or battery maintenance If you have the following needs Power saving plan Low power icon shows on the screen or the power indicator lights on when the terminal is in use Long press the power key and choose Turn Off The terminal will not be in use for 5 mins or more Make sure no low power icon displayed and the power indicators doesn t light on Switch to sleep mode by pressing the Power key The term...

Page 22: ...1 Features of ScanPal EDA50 Enterprise Hybrid Device 14 ScanPal EDA50 Enterprise Hybrid Device User Guide Store the battery outside the terminal Put the battery in the charger ...

Page 23: ...s If you need to replace the battery please contact Honeywell service representatives or the resellers There are security risks in waste batteries Before cleaning up the battery stick the poles with insulation tape Do not modify the battery or attempt to insert foreign objects into the battery Do not solder directly to the battery poles Do not short connect the battery and put the battery away fro...

Page 24: ...e note after complete the installation instructions the welcome interface will not appear again The interface appears as locked screen interface after each time you turn on the terminal Unlocking the screen Every time you turn on the terminal you need to unlock the screen Slide the lock icon to any edge of the screen to unlock it After the EDA50 is deployed we suggest you to set password to protec...

Page 25: ...ide 17 Scanning Indicator The scanning indicator indicates the status of the scanner For barcode scanning method please refer to the chapter Scanning barcodes Scanning indicator definition Light of the indicator Meanings Green Good read for the barcodes Red Barcodes reading failed Scanning Indicator ...

Page 26: ...nvironment 1 Tap Settings 2 Tap Display Brightness 3 Tap Auto to automatically adjust the backlight intensity or slide adjustment bar to set the backlight intensity Audio features EDA50 is equipped with speaker receiver and software utilities for volume setting Adjusting the ringtone volume for calls and messages With the volume key on the side of the terminal you can quickly adjust the ringtone v...

Page 27: ... Enterprise Hybrid Device ScanPal EDA50 Enterprise Hybrid Device User Guide 19 1 Press the key on the right side of the terminal or Volume bar will show on the screen 2 Adjust the volume by pressing volume key or slide volume bar ...

Page 28: ... EDA50 Enterprise Hybrid Device User Guide Enabling vibration mode In office environment you can enable the vibration mode for the terminal and mute the speakers 1 Long press the power key Power options will be displayed on the screen 2 Tap Enabling vibration mode ...

Page 29: ... can also be adjusted by the volume key on the side of the phone Alarm and alert tones Ringtones Model EDA50 111 Select one of the rigntones Vibrates when ringing Model EDA50 111 If checked the terminal will vibrates when a call is in Default notification tone Select notifications tones Dialpad touch tones Model EDA50 111 If checked the dial tone will be enabled Touch tones If checked touch tone w...

Page 30: ...to the unlock position at right 3 Open the battery cover with the battery cover buckle handle 4 Pull out the battery First open the battery connector side then pull out the battery 5 Insert the Micro SD card to SD card slot until it taps 6 Insert the battery Insert the non connector side first then press the battery down to establish connection between the battery and the phone 7 Press down the ba...

Page 31: ...ansfer camera photos you can use PTP Picture Transfer Protocol connection settings If the computer with Windows system doesn t support MTP you can use PTP transmission Note EDA50 supports high speed USB communication USB2 0 with maximum data transfer rate at 480 Mbps 1 Connect EDA50 to the computer 2 Select Media device MTP or Camera PTP on the EDA50 screen EDA50 will set your selection as default...

Page 32: ...ase contact your local sales representatives EDA50 s accessories and descriptions Accessories Description EDA50 battery BAT EDA50 This battery can last several hours to power EDA50 Spare battery packs can be ordered to extend the service time Wall charger Used for charge EDA50 Single Cradle Single Charging cradle Single Cradle can be used to place EDA50 with battery in to charge the main battery p...

Page 33: ...se Hybrid Device User Guide 25 2 User interface and applications This chapter introduces the Android system user interface and how to interact with the screen Users can also learn about a variety of Honeywell applications on the terminal through this chapter ...

Page 34: ...main interface description Name Description Status bar The left side of the status bar displays system messages sent by the application such as information notifications The right of the status bar displays the current wireless and network connection status and remaining battery power Common applications The applications on this bar will be displayed on the main interface All Applications option i...

Page 35: ...e apps System settings Home Key Return to the main interface Volume Increase or decrease the speaker volume Scan Button Press and hold to scan graphics Power key Turn on turn off lock the screen Reset Button Reset the system Status bar icons Status and notification icons display the current network connections power notifications and sound settings Please refer the following table for detailed sta...

Page 36: ...with a Bluetooth enabled device ABD has been enabled USB troubleshooting has been enabled Bluetooth has been enabled Data Sync Wi Fi signal is adequate Sync or account logon failed Wi Fi is connected but with no signal Memory card is full Network connected Key mapping Users can change the default functions of the left and right scan keys 1 Tap All Applications Settings Key Remap 2 Touch the keys y...

Page 37: ...ge swipe up from the bottom of the screen or tap Return key or Home key Managing system messages When the applications send system messages to EDA50 users can manage them quickly 1 When the system message icon appears swipe down the screen 2 To manage the system message touch it The respective application will be opened for users to manage it Swipe the system message to the side to clear it Tap th...

Page 38: ...bar to open these applications more quickly 1 Tap To display all applications 2 Long press the icons in the common application bar and slide it to the X Delete on the top of the interface 3 To add application icon to the common application bar long press the application to be added and slide your finger to place the icon on the common application bar To add the widget to the common application bar...

Page 39: ...can rearrange some shortcuts on the main interface Swipe or slide Quickly move your finger on the screen and keep your finger touching on the screen For example users can swipe the home screen to the left or right to view other home screens Double click tap twice rapidly in a row on the map or other interface to enlarge it Double click again to return to the original size Kneading In some applicat...

Page 40: ...C Demo and more included allows testing and using functions like scanning Auto Install Settings This application can automatically identify and install installation packages and APK files Unlocking developer options If you are a developer for EDA50 you can easily unlock developer options Developer options can help you test and troubleshoot during the process of developing EDA50 After Developer opt...

Page 41: ...3 Scan Function ScanPal EDA50 Enterprise Hybrid Device User Guide 33 3 Scan Function This chapter describes how to scan barcodes and set scan functions ...

Page 42: ...e applications that can accept scan wedge function through scanners or applications If an application obtains scan function through Barcode Reader API the scan wedge function will be temporarily disabled Users can build customized applications in Software Development Kit SDK for ScanPal EDA50 Please download SDK at www honeywellaidc com Processing and settings for scanned data Processing steps Res...

Page 43: ...nput the final data as Android Key Events Data processing settings wedge Prefix and suffix will be replaced within the string value Prefix and suffix parsing Substring Replacement character code Wedge in form of KeyEvent r 13 No n 10 Yes t 9 Yes No Changing scan settings Changes made to the default file apply for all non document applications 1 Tap Settings 2 Tap Scanning 3 Tap Default 4 Select Da...

Page 44: ... table to learn about Data Processing Settings Symbology Settings Decode Settings Imager Settings and Trigger Settingsand Notification Settings Data processing settings Use data processing settings to set the barcode data processing patterns for EDA50 Data processing settings Settings Description Default Wedge Enable or disable the transferring of barcode data as Android Events when sending data t...

Page 45: ...r https the browser will open the respective URL The related BarCodeReader attributes PROPERTY_DATA_PROCESSOR_LAUNCH BROWSER Enabled Scan Intent Enable or disable scan processing for specified targets Apply the barcode as the follwing format ACTION intent suffix extra data Where Additional operations and data include the following characters to enable Intent or respective applications Intent actio...

Page 46: ...se Hybrid Device User Guide Start EZ Config Enable or disable specifying EZ Config operations to barcode Adopt Aztec code and include specified header data The related BarCodeReader attributes PROPERTY_DATA_PROCESSOR_LAUNCH_EZ_ CONFIG Enabled ...

Page 47: ...a symbol to view and modify the configuration parameters of the symbol Symbology settings Settings Default Code 128 Enabled GS1 128 Enabled Code 39 Enabled Datamatrix Enabled UPC A Enabled UPC E Disabled EAN 8 Disabled EAN 13 Enabled Aztec Enabled China Post Disabled Codabar Enabled Codablock A Disabled Codablock F Disabled Code 11 Disabled Code 93 Disabled ...

Page 48: ...A 2 of 5 Disabled Interleaved 2 of 5 Enabled Korean Post Disabled Matrix 2 of 5 Disabled Maxicode Disabled Micro PDF 417 Disabled MSI Disabled PDF 417 Disabled QR Code Disabled RSS GS1 Disabled Standard 2 of 5 Disabled Telepen Disabled TLC 39 Disabled Trioptic Disabled 2D Postal Settings Disabled OCR Disabled ...

Page 49: ...d image settings can be applied in many environments only the users who have more in depth understanding on the image can change the settings Trigger settings Trigger settings can set up the using patterns for scan key Trigger settings Settings Description Default Decoding timeout If the scan trigger is held down but decoding is not successfully performed Scanning will automatically shut down afte...

Page 50: ...ption Default Good Read Notification Enable or disable Good Read Notification Notification includes green indicator short beep and optional short vibration Enabled Bad Read Notification Enable or disable Fail to Read notification Notification includes red indicator failure beep and optional short vibration Disabled Vibrate Enabled Regardless of succeeding or failing to read turn on or off the phon...

Page 51: ... a barcode you only need to enable the desired barcode symbology in the settings 1 Tap Applications Demos ScanDemo 2 Align the scanning window with the barcode and stably place the terminal a few inches away from the barcode 3 Press one of the scan keys or tap Scan on the interface Make sure the entire barcode is within the scanning beam range When the scanning is successfully completed you will h...

Page 52: ...ion 44 ScanPal EDA50 Enterprise Hybrid Device User Guide 4 Using Telecommunication Function You can use the phone function of the terminal Only for EDA50 111 to make and receive calls and to transmit data via wireless network as well ...

Page 53: ...e function and activate the service through wireless carriers they can customize the phone features and network settings in the Mobile Network interface in Settings Note WWAN version supports automatic system time setting with network messages and timezone messages NITZ Activating UMTS calls UMTS calls can be activated by inserting Micro SIM card in the terminal Micro SIM card can be purchased fro...

Page 54: ...hen press the battery cover down 8 Press down the battery cover safety button to move the battery cover safety lock to the lock position at left 9 Turn on the terminal Making a call After the phone is successfully activated you can make calls 1 Tap in the main interface or application interface If the screen shows the list of numbers instead of a dial keypad tap to get back to the dial keypad 2 Ta...

Page 55: ...n network data during the call Due to restrictions from network carriers you can not receive multiple simultaneous calls and connections and voice calls will get priority For more information please contact your network carrier During the call tap the icon of other applications on the main interface or application interface to run the application while the green call icon shows in the status bar M...

Page 56: ...5 Using Camera 48 ScanPal EDA50 Enterprise Hybrid Device User Guide 5 Using Camera This chapter describes how to use a color camera to take photos and videos ...

Page 57: ...te directions to zoom out the images Changing camera settings In order to obtain the best results when taking photos users can change the camera settings beforehand 1 Tap All Applications and then tap Camera 2 Tap the Flash Light icon on the bottom right to view Camera Options 3 Tap HDR or any icons to change the basic settings of the camera When HDR is enabled the terminal will automatically capt...

Page 58: ...mera Shooting Options on the bottom left 3 Tap to choose videos 4 Tap to start video shooting To adjust the focus you can knead two fingers on the screen to capture images you can tap on the screen for instant capturing during video shooting process 5 To stop video shooting tap Changing video settings In order to obtain the best results when shooting videos users can change the camera settings bef...

Page 59: ...ations ScanPal EDA50 Enterprise Hybrid Device User Guide 51 6 Terminal configurations This chapter describes how to configure EDA50 Users can also learn about how to configure network communications and wireless security ...

Page 60: ...etwork settings These parameters set by the user decide how the terminal works Users can configure the terminal in Application Settings Start Application Settings Application Settings is in Applications Menu Tap Applications Settings Structure of the Application Settings The section describes the structure of Application Settings to make it easier for users to quickly locate respective specificati...

Page 61: ...isable Airplane mode Mobile network including mobile network settings such as to enable data transceiver and roaming select the transceiver point and carriers or choose only to enable 2G mode to extend battery life Default SMS application SMS application is enabled by default NFC enabling NFC allows NFC tag information to be read when the terminal touches NFC tag Android Beam when NFC is enabled t...

Page 62: ...current battery status Applications Shows applications downloaded and on the run Personalization Settings Introductions Location information To enable or disable location information Google and GPS satellite data Security Set screen lock and administrator privileges including application installation and data storage security Language input Select the current language and the default keyboard Set ...

Page 63: ...D lighting modes Scanning Configure ScanPal EDA50 imager For more help please refer to changing scan settings Adding accounts Settings Introductions Adding account Set up an e mail account System Settings Introductions Data Time Configure all time and date settings Auxiliary functions Set auxiliary function level for example large font and text to speech output Printing Configure printing options ...

Page 64: ...th USB Connecting to Wi Fi networks When communicating through wireless networks ScanPal EDA50 transfer data through 802 11 radios Before connecting to a Wi Fi network users need to know the Security Protocol of the network and the certificates it required Usually 802 11 radio is diabled by default 1 Enter Settings slide the WLAN switch to enable it 2 When the WLAN switch turns blue tapping the WL...

Page 65: ...ertificate name password or other credentials To connect to a secure network enter the required information and then tap Connect To leave the network that has been connected tap Forget For example users can choose to forget a network that they won t use again To close the network information screen tap Cancel Configuring Wi Fi network proxy servers If users need to connect to network resources thr...

Page 66: ...Show Advanced Options at the bottom of the network setting list 4 If the network does not have proxy server settings tap None on the proxy server setting list and then tap Manual Settings 5 Enter the network proxy server settings 6 Tap Save Disable Wi Fi notifications Wi Fi is enabled by default Users will receive notifications in the Status Bar when the terminal finds wireless networks Users can ...

Page 67: ...ication Settings screen 2 Tap More under Wireless and Networks 3 Tap VPN 4 Tap Adding 5 Input the VPN information 6 Tap Save and VPN name will be displayed in the list Connect to VPN 1 Enter Application Settings screen 2 Tap More under Wireless and Network 3 Tap VPN 4 Tap the VPN name in the list and enter the certificate information based on the tips 5 Tap Connect The terminal gets connected to t...

Page 68: ...droid supports DER encoded X 509 certificate stored in the documents with crt or cer extension Install a valid DER format certificate Android also supports X 509 certificate stored in PKCS 12 key store file with p12 or pfx extension To install a valid key storage file with other extensions at the end users must change the extension to p12 or pfx first If users installed a certificate from the PKCS...

Page 69: ...an disable or delete the certificate 1 Enter Application Settings tap Safety Trusted Credentials There are two tabs in the Trusted Certificate screen System tab displays CA certificates installed in ROM User tab displays CA certificates installed by users 2 Tap the certificate name to disable or delete it and the certificate details screen will pop up 3 Slide the screen down to the bottom tap Disa...

Page 70: ...radio is disabled Bluetooth radio can be restored to its current state by system resetting If users have reset the system data they must re establish the paired devices Bluetooth status is displayed on the System Icon bar Pairing with a Bluetooth enabled device To connect to a Bluetooth enabled device users should enable Bluetooth radio first and then choose the device from the detected device lis...

Page 71: ...s detectable and then tap Scan Device 5 Select the device to pair with After Pairing Dialog Box is displayed enter the device PIN code and tap OK When the device and the terminals have been successfully paired the device name will appear in the list of paired devices at the top 6 To disconnect with the paired device tap the Quick Setting icon beside the device name and then tap Cancel Pairing ...

Page 72: ... received files Searching for EDA50 By default EDA50 is not detectable by other devices which means it s not visible for other Bluetooth enabled devices 1 Tap All Applications Settings 2 Make sure Bluetooth radio has already been enabled 3 Tap Bluetooth 4 Tap ScanPal EDA50 the default terminal name at the top of the screen to change it to be detectable Then the terminal begins 2mins countdown duri...

Page 73: ...rmation about accessories please contact local resellers Near Field Communication NFC technology provides short range wireless data transmission between ScanPal EDA50 with NFC tags or other NFC enabled devices near its back NFC enabled ScanPal EDA50 models support the following operations NFC tag read write mode The terminal reads digital information from the NFC tag or writes information into NFC...

Page 74: ...7 Management and maintenance 66 ScanPal EDA50 Enterprise Hybrid Device User Guide 7 Management and maintenance This chapter will describes how to upgrade softwares reset terminals and maintain EDA50 ...

Page 75: ...p to the root directory of the T card 2 Restart the terminal when the green light of the device turns on press and hold the left Scan key Volume key at the same time when the green light turns off the terminal will automatically select the zip package and install it 3 After the installation is complete the terminal will restart automatically Manually upgrading Recovery Menu 1 Copy the file eda50 o...

Page 76: ...nal Reset Restart the terminal and initialize it Restore to factory settings Clear all data in the terminal including all applications and data files but excluding built in files or data stored in a removable storage device Terminal resetting When an application is not responding you may need to restart the terminal to resolve the issue 1 Save the file and close open applications 2 Press and hold ...

Page 77: ...nvironmental conditions where the terminal is being used clean these parts at regular intervals Use a clean soft cloth dampened with the following solvents for the cleaning and quickly wipe it with another piece of clean soft cloth Acetic acid 10 soluble in water Ethanol 10 soluble in water Neutral soap solution Warnings this product includes non user serviceable parts inside Disassembling the pro...

Page 78: ...ntration Warnings this product includes non user serviceable parts inside Disassembling the product may prevent warranty and cause internal damages to the product Note We advise you not to open the battery cover or remove the battery so as to avoid the liquid flowing into the internal part of the terminal from the SIM card and SD card interface 1 Press the power key to enter standby mode 2 Dip a c...

Page 79: ...h 153 5 mm Width 78 9 mm Thickness 18 mm Weight with battery 270 g with battery Tumble and drop standards Tumble 200 tumbles within 0 5m Drop Multiple 1 2m drops to concrete at room temperature Power and electrical specifications Battery Rechargeable Li ion battery 3 8v 4000mAh Charging power 5 V 2 A Temperature and humidity specifications Operating temperature 10 C to 50 C 14 F to 122 F Storage t...

Page 80: ...viewing angle touch screen Language Support Language Support and not limited to WW English French German Italian Spanish Simplified Chinese Traditional Chinese Symbolgies support The following symbologies are supported 1D codes Codabar Code 3 of 9 Code 11 Code 32 Code 93 Code 128 EAN 8 EAN 13 GS1 128 Korea Post IATA 2 of 5 Industrial 2 of 5 Interleaved 2 of 5 ISBN ISBT 128 Matrix 2 of 5 MSI Plesse...

Page 81: ...c Code UPC A UPC E 2D codes Aztec Code Codablock A Codablock F DataMatrix HanXin Maxicode Micro PDF 417 MicroQr PDF 417 QR Code TLC39 OCR A OCR B Postal codes Australian Postcode Canadian Postcode KIX Dutch Postcode Japanese Postcode UK Postcode Planet Code Postnet UsIntelligent Info mail UPU ID tag ...

Page 82: ...he barcode 23 C 73 F 0 10K lux Clear high quality barcodes Note If the barcode is not aligned well with the scan engine reading time and depth of field DOF will be affected and the device performance will be decreased Short range in cm Long range in cm Increments in cm 5mil code39 128 2 5 6 3 4 3 10 9 1 8 4 6 13mil UPC A 2 2 5 5 10 5 27 8 8 3 22 3 6 7mil PDF417 2 2 5 5 4 6 11 7 2 4 6 2 20mil QR 1 ...

Page 83: ...uctivity Solutions 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com ScanPal EDA50 for Android User Guide P N EDA50 ENG UG Rev A http www cn security honeywell com 2015 Honeywell International Inc All rights reserved ...

Reviews: