Honeywell ScanDome ll HTX-3000 Instruction Manual Download Page 9

 

2.1.2 Single Multiplexer 

 

RS-485(-) PIN No.5

RS-485(+) PIN No.4

POWER

AC 24V

AL5

AL6

GND

AL7

AL8

GND

COM

3

NC3

NO3

COM

4

NC4

NO4

AL1

GND

AL2

AL3

GND

AL4

COM

1

COM

2

NO1

NC1

NO2

NC2

AC

+

RX

-(T

X

-)

R

X

+(

T

X

+)

AC

-

(R

X

-)

FG

N

D

AC

+

AC

-

(R

X

+

)

GN

D

RS

-4

85

(RS-422)

(RX

+

)

(R

X

-)

R

X

+(

T

X

+)

R

X

-(T

X

-)

AC 24V

POWER

POWER

AC 24V

BNC

MULTIPLEXER

SPOT MONITOR

MAIN MONITOR

BNC

BNC

AWG # 24

 

 

                                                             Figure 3 – Single Multiplexer

 

Summary of Contents for ScanDome ll HTX-3000

Page 1: ...ScanDome ll KEYBOARD CONTROLLER Please read this manual thoroughly before use and keep it handy for future reference Rev 2 04 10 05 Instruction Manual HTX 3000 HTX 3000 ...

Page 2: ... with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing in...

Page 3: ...Y CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DIGI...

Page 4: ...being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way ...

Page 5: ...ON 2 1 Connection Diagram 8 2 2 Termination Dip Switch Setting 12 2 3 Keyboard Setup 13 2 4 Master Slave Keyboard Setting 15 Chapter 3 0 OPERATION 3 1 Keyboard Lock Unlock 16 3 2 Controlling Multiplexer 16 3 3 Summary of Keyboard Control 18 Appendix A Trouble Shooting 21 Appendix B SPECIFICATION 22 ...

Page 6: ...lity to define and run up to 8 scans which scan between two limits The capability to incorporate up to 300 of the presets patterns scan and tour itself in up to 8 tours where the presets patterns and scan automatically displayed one after the other on the Main monitor Global preset recalls preset of all dome cameras Auto Iris mode activated by moving the joystick slightly Auto Focus mode is activa...

Page 7: ...Unpack the equipment and make sure all listed items are included in the box Contents of Keyboard box Keyboard controller 1 Junction box 1 3m cable 2 M4 Self tapping screws 4 Instruction manual 1 12VDC SMPS Power Cord 1 ...

Page 8: ...TX RS 485 ALARM INPUT UP TO 8 ALARM INPUT LIGHT SIREN SENSOR DOME1 DOME1 AWG 24 BNC BNC MONITOR AC 24V POWER RX TX RX TX RX RX RS 422 RS 485 GND RX AC AC FGND RX AC RX TX RX TX AC NC2 NO2 NC1 NO1 COM2 COM1 AL4 GND AL3 AL2 GND AL1 NO4 NC4 COM4 NO3 NC3 COM3 GND AL8 AL7 GND AL6 AL5 AC 24V POWER RS 422 SIMPLEX MODE TX TX DUPLEX MODE TX TX RX RX Figure 2 Basic installation diagram ...

Page 9: ...AL6 GND AL7 AL8 GND COM3 NC3 NO3 COM4 NC4 NO4 AL1 GND AL2 AL3 GND AL4 COM1 COM2 NO1 NC1 NO2 NC2 AC RX TX RX TX AC RX FGND AC AC RX GND RS 485 RS 422 RX RX RX TX RX TX AC 24V POWER POWER AC 24V BNC MULTIPLEXER SPOT MONITOR MAIN MONITOR BNC BNC AWG 24 Figure 3 Single Multiplexer ...

Page 10: ... AC AC FGND RX AC RX TX RX TX AC NC2 NO2 NC1 NO1 COM2 COM1 AL4 GND AL3 AL2 GND AL1 NO4 NC4 COM4 NO3 NC3 COM3 GND AL8 AL7 GND AL6 AL5 AC 24V POWER Figure 4 Two Multiplexer Spot output of the first multiplexer to be connected to 16 th input of the second multiplexer And first spot output of the 2 nd multiplexer to be connected to the spot monitor You will see the picture of the selected camera 1 31 ...

Page 11: ... RX TX AC RX FGND AC AC RX GND RS 485 RS 422 RX RX RX TX RX TX AC 24V POWER POWER AC 24V BNC AWG 24 Spot output 1 of the first multiplexer to be connected to 16 th input of the second multiplexer n User Spot out of n th to be connected to 15 n th camera input of the 2 nd multiplexer n th spot out of the 2 nd multiplexer to be connected to the n th use spot monitor Each user will see the picture of...

Page 12: ...the cable for communication should not exceed 1 2 km Refer to Figure 7 for setting the dome camera and keyboard controller termination Termination and Master Slave Set the switches according to your configuration ON 9J 1 2 3 4 5 6 7 8 S2 Figure 7 Keyboard DIP Switches Termination should be On Cable for communication Cable for communication Figure 6 Termination and ID Switches Termination should be...

Page 13: ...needs login password to operate Keyboard again Chg User Pin Change 4digit of user password CurrentPin Enter 4 digits of current user s password NewPin Enter 4 digits of new password ConfirmPin Confirm 4 digits of new password Chg Admin Pin Change 4 digits of administrator s password CurrentPin Enter 4 digits of new password NewPin Enter 4 digits of new password ConfirmPin Confirm 4 digits of new p...

Page 14: ...he dome camera menu at slave keyboard Release INF 001 200s INF Infinite Slave Keyboard user never have the control right of the dome which is selected by master Keyboard users 1 200s Second After elapse of programmed time since master Keyboard user use the dome slave Keyboard user can get the control right of the dome Save and Exit Save the programmed data and return to the previous Menu Exit Data...

Page 15: ... dip switch the 7th of S2 ON 2 If you setup all connection correctly See Figure 4 and turn on slave keyboard you can see following screen 3 Press Ctrl Menu Set the Slave ID to 01 4 Set Slave Node to B in case that master keyboard model is HTX 3000 and to B in case HTX 2000 SCANDOME II Vxxx Slave ID 1 Input Password xxxx CAM 000 Current Device ID 1 Default setting is 9999 for administrator 1111 for...

Page 16: ...nd hold down the Enter Key while navigating using the joystick Enter Joystick Triplexer Push the Jostick to upward with Enter pressed Enter Joystick will show the Mux menu It will act like a mouse Rotatingthe handle clockwise will act like the set key of the multiplexer Rotating counterclockwise will act like the ESC key of the Multiplexer 3 2 2 Dome Camera Selection There are three types of dome ...

Page 17: ...m Successive camera call is valid on two Mux configuration only For example 1 Cam will switch camera 1 to the second multiplexer spot output and you can control all functions of the selected camera using the keyboard controller If you install more than two Multiplexers the unit number ID up to 128 of the Multiplexer and selection of the Multiplexer must be the same in order to control the Multiple...

Page 18: ...exer 2 and the keyboard controller has control of the selected camera 31 Cam camera 15 of the second multiplexer 3 3 Summary of Keyboard Controls Cam 001E ZOOM WIDE ZOOM TELE IRIS OPEN IRIS CLOSE FOCUS NEAR FOCUS FAR MULTIPLEXER DVR CONTROL MULTIPLEXER IDR CONTROL Figure 8 Keyboard Key map Figure 9 J box Front Rear DVR CONTROL ...

Page 19: ...ur programming mode the operator can review the exiting preset selected by cursor by pressing this key Tour TOUR Pressing Tour will bring up the tour programming menu directly Recalls programmed presets or functions sequentially e g 1 8 Tour Pattern PTRN Pressing Ptrn will bring up the pattern programming menu directly Repeats the selected pattern of the current dome camera e g 1 4 Ptrn Auto Scan ...

Page 20: ...ay 4X4 Displays view of 16 cameras in 1 16 size pictures 2nd 2ND Second mode of PIP multiplexer Pressing 2nd Enter again will return to normal mode Panic record L REC Put a camera in the Panic Record Mode Macro MACRO Same as Menu key in the Duplexer model Same as Macro key in the Triplexer model Select or Alarm SEL Same as Select key in the Duplexer model Same as Alarm key in the Triplexer model F...

Page 21: ... Check that the dome camera IDs are set properly See Figures 1 to 7 Check the polarity of the data line Camera number does not match the multiplexer number 1 Check the camera ID and insert the BNC cable into the proper input of the multiplexer Forgot password 1 Consult your supplier distributor or service Center Multiplexer can t work with the Joystick controller 1 Check that the data cable for th...

Page 22: ...ipping Weight Communication 12VDC 5W RS 485 RS 232C 2400 230K bps 0 C to 50 C 32 o F to 122 o F 0 to 90 RH non condensing 20 C to 60 C 40 o F to 122 o F 380 x 168 x 96 mm 452 x 283 x 162 mm Approx 1 2kg Approx 3 0kg Dome Connection Max 32 Multiplexer Connection Max 255 Design and Product specifications subject to change without notice ScanDome lI KeyBoard Controller ...