The terminal is shipped with Factory Defaults set.  When power is initially applied, the script timer, alarm and 
operation definitions are cleared; the terminal then powers up, acquires the GPS position and tunes to the best 
ocean region for the terminal location.  Once the terminal has acquired the IDP satellite signal it transmits a 
single position report burst. 

 

Summary of Contents for SAT-IDP

Page 1: ...SAT IDP SAT IDP Series User Guide Document Number MAN 0077 Issue No 6 Dated 18th December 2020 Honeywell Global Tracking Ltd ...

Page 2: ...rein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2020 Honeywell International Inc All rights reserve...

Page 3: ...3 6 Operational Check 13 Chapter 4 Functionality 15 Chapter 5 Factory Defaults 16 Chapter 6 Maintenance and Support 17 6 1 Cleaning 17 6 2 Technical Support and Information 17 Chapter 7 Interfaces 18 7 1 SAT IDP Interface Pinout 18 7 2 Interface Functions 18 7 3 General Purpose I O 19 Chapter 8 Interpreting the Indicator 21 Chapter 9 Security Guide 22 9 1 Security Checklists 23 9 1 1 Infection by ...

Page 4: ... user serviceable parts inside Refer servicing to qualified service personnel The captive cable and gland nut on SAT IDP is not user replaceable tampering with these may void the warranty Damage to the cable could result in the terminal having to be replaced The equipment contains no replaceable fuses Observe all warnings on the equipment and in this manual Follow all installation and operating in...

Page 5: ...ED Directive 2014 53 EU Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU RoHS Directive 2011 65 EU WEEE Directive 2002 96 EC Relevant Standards Radio standards per Article 3 2 ETSI EN 301 426 v1 2 1 EMC standards per Article 3 1b ETSI EN 301 489 20 v1 2 1 ETSI EN 301 489 1 v1 8 1 Safety standards per Article 3 1a EN 62368 1 Ingress Protection Classification EN60529 1999 1 3 FCC Authorisat...

Page 6: ...nd to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communicatio...

Page 7: ...sed in a wide range of control and monitoring applications When third party equipment is attached such third party equipment and all cabling must be of suitable design and installation to ensure that the overall system complies with the requirements of the appropriate CE directives Guidance notes for the installation and use of the SAT IDP must be strictly followed Honeywell Global Tracking exerci...

Page 8: ...tion provides a data rate for the forward to terminal messages of approximately 3000 Symbols second with typical latency of 100 bytes 12 seconds 1 000 bytes 70 seconds Forward channel can contain 2 to 6400 bytes Return channel from terminal messages can contain 2 to 10 000 bytes with a typical latency of 100 bytes 20 seconds 1 000 bytes 45seconds Traffic channel on which messages to the terminal a...

Page 9: ...three magnetic mounting feet for use as a portable solution WARNING The SAT IDP SC magnetic feet are not designed for fitting to vehicles driven at speed or over rough terrain It is the user s responsibility to ensure that the equipment is secure when fitted to a vehicle and that the vehicle is driven safely ...

Page 10: ...ions When installing the SAT IDP adequate circuit protection must be provided as required by local regulations IMPORTANT If connecting to an external battery the SAT IDP requires an external fast acting fuse connected in series with the ve supply at the battery end of the cable Input voltage Fuse rating Minimum wire gauge 9 6 to 32 VDC 2A 24 AWG 7 0 2 IMPORTANT If an external AC DC Adaptor is used...

Page 11: ...in any doubt The SAT IDP should be located with an unobstructed clear view of the sky The SAT IDP should be mounted on a flat horizontal surface Consider the position of the satellites The Inmarsat satellites are in geostationary orbits above the equator i e in the Northern hemisphere the satellites are located to the South in the Southern hemisphere the satellites are located to the North The fur...

Page 12: ...mmended for installations exposed to shock and or high vibration and or uneven surfaces o Bore a central 40mm hole o Position the terminal centrally and mark the location of the three mounting holes o Drill three 4 5mm mounting holes o Secure the terminal in place using M4 No 8 nuts and bolts Do not over tighten 1 5Nm Max o Alternatively secure using fastenings appropriate to the mounting surface ...

Page 13: ...MAN 0077 Honeywell Global Tracking Ltd 11 Figure 4 SAT IDP M4 Drilling Diagram not to scale Figure 5 SAT IDP M25 Drilling Template not to scale ...

Page 14: ...MAN 0077 Honeywell Global Tracking Ltd 12 Figure 6 SAT 401C M25 Drilling Template not to scale Figure 7 SAT IDP Foam Washer Dimensions not to scale ...

Page 15: ...s possible to set up your terminal on one of the Honeywell Global Tracking websites in order to perform end to end testing Please consult your service provider for details of the activation that has been put in place for your terminal If you do not have access to the application it is still possible to check the local operation of the terminal and its installation by using the following sequence I...

Page 16: ...service provider as well as the link to the Honeywell Global Tracking server Your service provider will be able to supply you with further details regarding the normal use of the terminal as well as scripts and forward channel use WARNING The information in this chapter only applies to terminals that are set at Factory Default and with the default script installed see Chapter 5 Factory Defaults If...

Page 17: ...MAN 0077 Honeywell Global Tracking Ltd 15 Chapter 4 Functionality For full functional details of the SAT IDP contact your authorised dealer ...

Page 18: ...ts set When power is initially applied the script timer alarm and operation definitions are cleared the terminal then powers up acquires the GPS position and tunes to the best ocean region for the terminal location Once the terminal has acquired the IDP satellite signal it transmits a single position report burst ...

Page 19: ...on For technical support product queries and information please contact your equipment supplier or authorised dealer Alternatively contact Honeywell Global Tracking directly for details of your dealer EMS Technologies Canada Ltd Honeywell Global Tracking CA 400 Maple Grove Rd Ottawa ON K2V 188 CANADA Support email hgt tracking support honeywell com General email hgt info honeywell com General www ...

Page 20: ...uct number A021B01 7 1 SAT IDP Interface Pinout All SAT IDP models have the following pin cable connections Pin Function Cable colour code if supplied by Honeywell Global Tracking 1 0V cable screen Screen 2 Voltage In VIN Red 3 0V VIN Orange 4 I O 1 Yellow 5 OD_OUT Green 6 I O 3 Blue 7 I O 2 Purple 8 Rx Grey 9 Tx White 10 0V VIN Black 11 I O 4 Brown 12 I O 5 Pink 7 2 Interface Functions VIN VIN Ex...

Page 21: ...bility Analogue input 12 bit ADC 0 to 3 3V Low voltage digital output 3 3V Note on USB to RS 232 Converters Honeywell Global Tracking recommends the FTDI chipset USB to serial converters for use with the SAT IDP terminal and the terminal programming utility software 7 3 General Purpose I O Figure 8 shows a conceptual drawing of one of the general purpose I O s I On Digital in Digital out High volt...

Page 22: ...MAN 0077 Honeywell Global Tracking Ltd 20 Figure 9 shows a conceptual drawing of the open drain output OD_OUT OD_OUT Open drain 0V Vin Figure 9 SAT IDP output block diagram ...

Page 23: ... OFF Tracking Forward Channel GREEN OFF OFF OFF Idle ORANGE ORANGE ORANGE ORANGE Transmitting In IDP mode the terminal stores Bulletin Board information in internal non volatile memory and only needs to tune to the Bulletin Board if the internal information needs updating or if a Traffic channel cannot be found Therefore from power on the Acquiring Bulletin Board and Demodulating Bulletin Board st...

Page 24: ...MAN 0077 Honeywell Global Tracking Ltd 22 Chapter 9 Security Guide Figure 10 Typical SAT IDP Installation System Architecture ...

Page 25: ...ps Ensure virus protection is installed signature files are up to date and subscriptions are active on all machines hosting Honeywell products Recommend that all SAT IDP software installed should be authorized and approved by Honeywell Use a firewall at the interface between other networks and Honeywell components 9 1 2 Unauthorized External Access This threat includes intrusion into your Honeywel...

Page 26: ...isable all unnecessary access ports ports that are not listed in the Network Ports table These ports may become gateway to intrusion 9 1 3 Unauthorized Internal Access This threat encompasses unauthorized access from people or systems with direct access to a Honeywell system component This threat is the most difficult to counter since attackers may have legitimate access to part of the system and ...

Page 27: ... passwords Monitor system access 9 1 4 Accidental System Change This threat encompasses inadvertent changes to executables or configuration files Accidental system change can result in Loss of system availability Loss of data Mitigation steps Set the minimum level of privilege for all accounts and enforce a strong password policy Ensure strong access controls are in place on the file system direct...

Page 28: ...ssing the security needs of your system and data it is important to consider the following environmental factors Dust Vibration Water Mobile Terminal is rated for IP 66 However when the unit work in a system environment need to ensure peripherals also rated equally Temperature and humidity Please refer the datasheet for temperature and humidity range of operation 9 2 1 2 Theft Prevention A major c...

Page 29: ...ibration SAE J1455 MIL STD 810G Vibration Ingress Protection IP rating IP66 Frequency Range Transmit Band 1626 5 MHz 1660 5 MHz Extended Transmit Band 1668 MHz 675 MHz Receive Band 1525 MHz 1559 MHz Extended Receive Band 1518 MHz 1525 MHz GPS 1575 42 1 0 MHz Elevation Angle Elevation Angle 0ºto 90º Transmitter EIRP 0 9dBW Modulation 2 level FSK 256Hz tone spacing Transmit burst duration 2s or 8s M...

Page 30: ...9600 bps Parity data bits stop bits N 8 1 Data Interfaces 5 x I O Individually configurable as High voltage digital input 32V max with falling edge interrupt capability Switch input internal pull up used with external switch to ground Digital input TTL with falling edge interrupt capability Analogue input 12 bit ADC 0 to 3 3V Digital output 3 3V 50µA typical 1 x Open drain output 250mA max sink cu...

Page 31: ...without charge except for return shipping to HII EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT HII S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY U...

Page 32: ...MAN 0077 Honeywell Global Tracking Ltd 30 Appendix C Declaration of Conformity Waiting for Conformity ...

Page 33: ...MAN 0077 Honeywell Global Tracking Ltd 31 Appendix D Inmarsat Type Approval Certification in progress ...

Page 34: ...t the following information be completed at the time of installation purchase to ensure that any future warranty claims are dealt with as expeditiously as possible IMPORTANT Please keep in a safe place for future reference NOTES DATE OF PURCHASE PURCHASED FROM SAT IDP ISN SAT IDP SERIAL NUMBER ...

Page 35: ...EMS Technologies Canada Ltd Honeywell Global Tracking CA 400 Maple Grove Rd Ottawa ON K2V 188 CANADA Web www gt honeywell com ...

Reviews: