52
Site Hardware
Caution
Do not “T-tap” the cable; this can introduce unwanted distortion into the
video signal. To obtain a video feed, use an output port on the Multi-Media
LT DVR.
Using LocalView for Public Display
You have the option of using VGA monitor(s) as a public display monitor. Set LocalView to
display the camera(s) that you need. More than one camera can be displayed
simultaneously. For a better public display of video, and if displaying one video feed at a
time is satisfactory, Honeywell recommends using a dedicated NTSC (or PAL) monitor,
rather than the VGA output used for LocalView.
Connecting a PTZ Dome
Connection to the DVR
Connect the Data In port of a PTZ dome (an RS485 connector) to one of the ports on a
Multi-Media LT DVR. Serial ports 3 and 4 do not need a 232/485 converter.
Figure 5-3
Serial Ports 1 to 4
ACUIX Camera
An ACUIX™ PTZ camera dome with Intellibus™ can be connected to a Rapid Eye
Multi-Media LT DVR and configured using Rapid Eye View software.
1. Set ACUIX cameras to their Intellibus mode (Intellibus-PTZ).
SERIAL PORT 2
SERIAL PORT 1
VGA
TELCO
USB
USB
LAN
IN
OUT
NOT
USED
1
2
3
4
5
6
7
8
SPOT
MONITOR
VIDEO
INPUTS
COMMON
SYS FAIL
SYS GOOD
F
AULT
RELAY
28V, 3A
MAX
1 G
G
G
G
2
3
4
CONTROL
OUTPUTS
SERIAL
PORT 3
SERIAL
PORT 4
1 G
G
G
G
2
3
4
5 G
G
G
G
6
7
8
ALARM
INPUTS
ON/OFF
POWER
115-230V~
50/60 Hz
5-3A
Serial Ports 3
and 4: RS485
ports (8-pin)
for
and for serial
Serial Ports 1 and 2:
RS232 ports (9-pin)