69-0618—3

4

R4184D; R8184G,M,N,P Protectorelay

 ®

 OIL PRIMARY CONTROLS

M1560A

USED FOR 4 AMP THERMOSTAT ONLY.

CAD 
CELL

F

R

W

Y

THERMOSTAT

G

FAN RELAY

COOLING 
CONTACTOR

W

C

R

Y

F

G

(T)

(T)

R8184M 
PROTECTORELAY
CONTROL

K1

SS

SAFETY 
SWITCH 
HEATER

R4

1K1

BLUE

RED

BROWN

TRIAC

BILATERAL 
SWITCH

CAPACITOR

R2

R1

1K2

BLACK

WHITE

ORANGE

BLACK

JUNCTION 
BOX

IGNITION

OIL VALVE

BURNER

LIMIT

L1 

(HOT)

L2

1

1

®

Fig. 6. Typical hookup for R8184M.

Fig. 7. Typical hookup for R8184N.

JUNCTION BOX

THERMOSTAT

BLACK

ORANGE

WHITE

R2

SAFETY
SWITCH

M717A

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

TO USE R8184N WITH LINE VOLTAGE CONTROLLER, JUMPER T1-T2 TERMINALS AND  CONNECT 
LINE VOLTAGE THERMOSTAT IN SERIES WITH LIMIT CONTROLLER.

CAD CELL

F1

T1

T2

F2

R8184N PROTECTORELAY   CONTROL

SAFETY 
SWITCH 
HEATER

1K

TRIAC

BILATERAL 
SWITCH

CAPACITOR

R1

1K2

1K1

1

2

2

2

1

IGNITION

LIMIT

LINE VOLTAGE
THERMOSTAT

OIL VALVE
(OPTIONAL)

BURNER
MOTOR

.4064T
HEATER

L2

L1 

(HOT)

®

Summary of Contents for R4184D

Page 1: ... on delay and blower off delay in this control are only intended to help establish draft and reduce oil after drip related problems INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow instructions can damage the product or cause a hazardous condition 2 Check ratings given in the instructions and on the product to make sure the product is suitable for you...

Page 2: ...AY CONTROL SAFETY SWITCH HEATER 1K TRIAC BILATERAL SWITCH CAPACITOR R1 1K2 1K1 1 1 IGNITION LIMIT THERMOSTAT OIL VALVE OPTIONAL BURNER MOTOR L2 L1 HOT Alarm Contact Rating 25 VA at 24V 50 60 Hz Mounting 쐃 If necessary use the control as a template to mark and drill new mounting holes 쐇 Mount the control using no 8 screws obtained locally Low Voltage Wiring Connections After mounting make low volta...

Page 3: ... VOLTAGE THERMOSTAT OIL VALVE OPTIONAL BURNER MOTOR L2 L1 HOT Fig 4 Typical hookup for R8184G JUNCTION BOX THERMOSTAT BLACK ORANGE WHITE RED RED R2 SAFETY SWITCH SAFETY SWITCH TO REMOTE ALARM CIRCUIT M5172A POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED TO USE R8184 WITH LINE VOLTAGE CONTROLLER JUMPER T T TERMINALS AND CONNECT LINE VOLTAGE THERMOSTAT IN SERIES WITH LIMIT...

Page 4: ...1 HOT L2 1 1 Fig 6 Typical hookup for R8184M Fig 7 Typical hookup for R8184N JUNCTION BOX THERMOSTAT BLACK ORANGE WHITE R2 SAFETY SWITCH M717A POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED TO USE R8184N WITH LINE VOLTAGE CONTROLLER JUMPER T1 T2 TERMINALS AND CONNECT LINE VOLTAGE THERMOSTAT IN SERIES WITH LIMIT CONTROLLER CAD CELL F1 T1 T2 F2 R8184N PROTECTORELAY CONTROL...

Page 5: ...LOW SWITCH AQUASTAT CONTROLLER BURNER MOTOR IGNITION TRANSFORMER VENTER MOTOR CAD CELL F R W RC Y G C R8184P PROTECTORELAY HYDRONIC CONTROL 4 LIMIT THERMOSTAT M10021 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 2 IGNITION TRANSFORMER CAN BE CONNECTED TO VALVE OR BURNER MOTOR 3 OMIT ON SYSTEMS WITHOUT POWER VENTING RED ORANGE BLACK VIOLET WHITE L1 HOT F L2 LINE 1 3 2 ...

Page 6: ...r running turn off the power to the system by tripping the circuit breaker or removing the fuse 쐋 Burner should stop 쐏 Restore power Burner should start If system does not operate as described go to the TROUBLESHOOTING AND MAINTENANCE section TROUBLESHOOTINGAND MAINTENANCE IMPORTANT 1 Only a trained experienced service technician should perform the troubleshooting procedure 2 This control contains...

Reviews: