T8205B,C, TS8205B,C ELECTRONIC POOL, SPA CONTROL SYSTEMS;
T8205A,H, TS8205A CONTROL MODULES; Q8205A-C SETPOINT PANELS AND SENSOR ASSEMBLY
68-0177—1
9
M11018A
VOLTAGE: T8205/Q8205 BETWEEN 21.5 TO 28.5V;
TS8205/Q8205 B0.2V AND 0.75V.
SET CONTROL TO MAXIMUM TEMPERATURE. AFTER
TWO TO THREE HEATING CYCLES, CHECK WATER
TEMPERATURE.
RESISTANCE 1 TO 15K ohms.
CHECK WATER TEMPERATURE; ESTIMATE EXPECTED
SENSOR RESISTANCE FROM SENSOR RESISTANCE TABLE.
MEASURED AND ESTIMATED RESISTANCE
MATCH WITHIN 20 PERCENT.
DISCONNECT POTENTIOMETER LEADS FROM CONTROL.
MEASURE RESISTANCE WITH OHMMETER.
IF RESISTANCE IS:
0 TO 100 ohms AT MINIMUM SETTING;
9 TO 11K ohms AT MAXIMUM SETTING,
REPLACE CONTROL MODULE.
ABOVE 11K ohms, REPLACE SETPOINT PANEL.
ABOVE 15K ohms, FIX LOOSE OR BROKEN WIRES;
REPLACE IF NECESSARY.
RECONNECT ALL LEADS AND CHECK OUT SYSTEM.
TEMPERATURE BELOW 105
°
F (40
°
C).
DISCONNECT SENSOR LEADS FROM CONTROL.
MEASURE SENSOR RESISTANCE WITH OHMMETER.
CHECK VOLTAGE: T8205/Q8205 24V TERMINALS;
TS8205/Q8205 + AND - TERMINALS.
VOLTAGE OUTSIDE RANGE: T8205/Q8205 21.5 TO 28.5V;
CHECK TRANSFORMER AND 120V SUPPLY; CORRECT
AS NECESSARY. TS8205/Q8205 +0.2V TO 0.75V,
CHECK GENERATOR; CORRECT AS NECESSARY.
RESISTANCE 0 ohms (SHORT CIRCUIT).
CHECK SYSTEM FOR SHORTED WIRES. REPLACE
SENSOR, IF NECESSARY.
MEASURED AND ESTIMATED
RESISTANCES DO NOT MATCH.
REPLACE SENSOR. RECONNECT ALL LEADS AND CHECK
OUT SYSTEM.
TEMPERATURE 105
°
(40
°
C) TO 106
°
F (41
°
C).
CONTROL OK; CHECK BALANCE OF SYSTEM.
60
°
F (16
°
C)
70
°
F (21
°
C)
80
°
F (27
°
C)
90
°
F (32
°
C)
106
°
F (41
°
C)
15K ohms
12K ohms
9K ohms
7K ohms
5K ohms
TEMPERATURE
EXPECTED
SENSOR RESISTANCE
FOR T8205B,C/TS8205B,C MODELS REPLACE THE CONTROL SYSTEM.
FOR T8205A,H/TS8205A MODELS, REPLACE THE T8205A,H/TS8205A OR
Q8205A–C AS APPROPRIATE.
1
1
1
YES
NO
YES
NO
YES
NO
YES
NO
Fig. 10. Troubleshooting procedure when water is too cold.