T8205B,C, TS8205B,C ELECTRONIC POOL, SPA CONTROL SYSTEMS;
T8205A,H, TS8205A CONTROL MODULES; Q8205A-C SETPOINT PANELS AND SENSOR ASSEMBLY
68-0177—1
3
Panel
Potentiometers
Switch
Positions
LED
Q8205A
1
none
none
Q8205B
1
On-Off
none
Q8205C
2
Pool-Off-Spa
optional
Table 4. Q8205A-C Setpoint Panels.
Electrical Ratings:
T8205 Power Supply: 18-30 Vac, 60 Hz.
T8205 Power Consumption: 3 VA at 24 Vac.
TS8205 Power Supply: 750 mV, dc.
Relay Contacts: Inductive: 2A full load, 10A locked rotor.
Resistive: 2A.
Temperature Setting Range:
61
°
to 106
°
F (16
°
to 41
°
C).
Setpoint Adjustment:
10K ohm, one-turn potentiometer.
Setpoint Accuracy:
±
1.5
°
F (0.8
°
C) at 106
°
F (41
°
C).
Ambient Temperature Range at Module:
T8205: -40
°
to +175
°
F (-40
°
to + 80
°
C).
TS8205: 0 to 175
°
F (0
°
to 80
°
C).
Differential (Not field adjustable):
1
°
F (0.7
°
C) maximum at 106
°
F (41
°
C), subtractive.
Sensor:
NTC thermistor sensor is imbedded in a copper bulb. Includes
leadwires with 3/16 in. female quick connects.
See Table 5.
Mounting:
T8205B,C and TS8205B,C Control Systems are mounted
on the appliance through mounting holes on the device.
Sensors are mounted directly into the header or in a
well.
IMPORTANT
T8205A,H, TS8205A Control Modules and Q8205A-
C Setpoint Panels must be mounted to allow
adequate electrical spacing according to approval
agency requirements.
T8205A,H and TS8205A Control Modules mount on any
flat surface using no. 6 screws (obtained locally)
through mounting holes.
Q8205A-C Setpoint Panels mount through holes on board
using no. 6 screws (obtained locally).
Sensing Bulb:
Can be mounted in immersion well or directly immersed,
using fittings to prevent leakage. Well or fitting supplied by
heater manufacturer.
Approvals:
International Approval Services (American Gas
Association and Canadian Gas Association) (IAS)
Certificate: C2030021.
Meets ANSI Standard Z21.23-1993.
Accessory:
Part no. 107408 Heat Conductive Compound in 4 oz. can.
Use when mounting sensor in a well.
Optional Features:
T8205B,C: LED indicator available for Heat-On indication.
Specify when ordering.
Dimensions:
See Fig. 1 for T8205B,C; TS8205B,C; Q8205A; T8205A,H;
TS8205A dimensions. See Table 5 for sensor dimensions.
Table 5. Sensors.
Sensor
Termination
Lead Length
Diameter
Capsule Length
Mounting
Material
198799E
3/16 in. quick connect
42 in. (1067 mm)
3/8 in. (10 mm)
2 in. (51 mm)
Compression
Copper
198799F
1/4 in. quick connect
48 in. (1219 mm)
3/8 in. (10 mm)
3 in. (76 mm)
Compression
Copper
198799H
3/16 in. quick connect
42 in. (1067 mm)
3/8 in. (10 mm)
2-5/8 in. (67 mm)
Spud
Copper
198799K
3/16 in. quick connect
42 in. (1067 mm)
3/8 in. (10 mm)
2 in. (51 mm)
Compression
Monel
198799R
3/16 in. quick connect
48 in. (1219 mm)
3/8 in. (10 mm)
3 in. (76 mm)
Compression
Copper
198799S
3/16 in. quick connect
96 in. (2438 mm)
3/8 in. (10 mm)
2-5/8 in. (67 mm)
Spud
Copper
198799W
3/16 in. quick connect
50 in. (1270 mm)
3/8 in. (10 mm)
2 in. (51 mm)
Compression
Copper