20
Applicator Interface Kit Installation Guide
• 10 ON PORTIN.PAUSE GOSUB 90
...
90 pause printer
Startprint
When the Startprint signal is received, the application moves to a specified
subroutine that starts the print job. The Startprint signal must be preceded by
the dataready signal as seen in this example.
Example
• 10 PORTOUT.DATAREADY on
20 ON PORTIN.STARTPRINT GOSUB 60
...
60 my print routine
70 PRINTFEED
80 RETURN
Reprint
When the Reprint signal is received, the application moves to a specified
subroutine that reprints the last valid label.
Example:
• ...
100 ON PORTIN.REPRINT GOSUB 150
...
150 PRINTFEED -1,1
160 RETURN
Printfeed
The dataready signal must be set manually by the Fingerprint application
before a printfeed is issued when using with an applicator.
Handling External Applicator Errors
When an error signal (apperr1, apperr2, or apperr3) is received, the application
moves to a specified subroutine that takes action based on error severity.
Example
• ...
60 ON PORTIN.APPERR1 GOSUB 100
...
100 perform error handling
110 RETURN