Applicator Interface Kit Installation Guide
11
Relay Out
The applicator card support 4 relay output ports. The relay of the OUT ports are
configured using the DC 5V and DC 24V settings. Relay 1 and Relay 3 are
configured by DC 5V setting and Relay 2 and Relay 4 are configured by DC 24V
setting. DC 5V and DC 24V settings are legacy applicator card settings, no
power is supplied by PX4IE/6IE applicator card. Any signals that are within the
max load breaking capacity of the relay can be connected to the relays.
Max AC Load Breaking Capacity
22
MediaOut_C
Media Out Collector Opto Out Channel
7
MediaOut_E
Media Out Emitter Opto Out Channel
37
RibbonOut_C
Ribbon Out Collector Opto Out Channel
23
RibbonOut_E
Ribbon Out Emitter Opto Out Channel
8
DataReady_C
Data Ready Collector Opto Out Channel
38
DataReady_E
Data Ready Emitter Opto Out Channel
24
VOID_C
VOID Collector Opto Out Channel
9
VOID_E
VOID Emitter Opto Out Channel
39
RTWOUTEXT_C
External output signal for Ready-to-Work
Indicator Collector Opto Out Channel
25
RTWOUTEXT_E
External output signal for Ready-to-Work
Indicator Emitter Opto Out Channel
Signal
Description
Max.
I
Current
1A
Psw AC
Switching power
100VA AC
Vsw AC
Switching voltage
100V AC
Pin
Signal
Description