Applicator Interface Kit Installation Guide
19
PORTOUT
Supports manually modifying the dataready signal. PORTOUT is not allowed
when the applicator port style is set to S-Style.
Note:
This command is not supported by Direct Protocol.
Example:
• PORTOUT.DATAREADY ON
• PORTOUT DATAREADY OFF
Where ON
asserts the dataready signal low and OFF de-asserts the dataready
signal high.
ON PORTOUT
This command allows a Fingerprint application to detect when out signals have
been reset to default values. The command moves to a specified subroutine
whenever the applicator port status is enabled, and whenever the applicator
port style is changed.
Example:
• ON PORTOUT.RESET GOSUB nnn
Fingerprint and Applicator Signals
When you use Fingerprint, all in signals and the Dataready out signal are
handled by Fingerprint. Other out signals are handled by firmware.
Feed
When the Feed in signal is received, the application moves to a specified
subroutine that feeds labels until the Feed in signal is de-asserted.
Example
• 10 ON PORTIN.FEED GOSUB 200
...
200 FORMFEED
210 RETURN
Pause
When the Pause in signal is received, the application moves to a specified
subroutine that finishes the current print job and then places the printer in
pause mode.
Example