background image

PRO 2000 Series

7

ENG

LISH

Fan switch

Use the 

Fan

 switch to select the fan operation.

Auto

: The fan runs only when heating or

cooling is activated (commonly used setting).

On

: The fan runs all the time.

69-1969EFS-07.book  Page 7  Tuesday, November 26, 2013  2:24 PM

Summary of Contents for PRO 2000 TH2110D

Page 1: ...Série PRO 2000 Series Programmable Thermostats Thermostats programmables Termostatos programables Operating Manual Mode d emploi Manual de Uso 69 1969EFS 07 book Page 1 Tuesday November 26 2013 2 24 PM ...

Page 2: ...his product please visit http yourhome honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 Read and save these instructions U S Registered Trademark Patents pending 2013 Honeywell International Inc All rights reserved CAUTION EQUIPMENT DAMAGE HAZARD To prevent possible compressor damage do not use Cooling mode when the outdoor temperature is below 50 F 10 C 69 1969EFS 07 book...

Page 3: ...On 7 Using the schedule 8 10 Temporary schedule override 11 Permanent schedule override 12 Adaptive Intelligent Recovery 13 Compressor protection 13 Appendices Battery replacement 14 In case of difficulty 15 Customer assistance 16 2 year limited warranty 17 Table of contents Your new thermostat is pre programmed and ready to go See page 2 for quick start 69 1969EFS 07 book Page 0 Tuesday November ...

Page 4: ...rature at all times One touch access to setpoint temperature Preprogrammed schedule can greatly reduce your heating cooling expenses Separate programmable weekday weekend schedules 5 2 day programming Temporary and permanent override of schedule Adaptive Intelligent Recovery ensures right temperature at the right time Built in compressor protection About your new thermostat 69 1969EFS 07 book Page...

Page 5: ...ge 6 Select whether to run the fan continuously or only when needed See page 7 If you do not wish to use the pre programmed schedule settings you can Modify the schedule See page 10 Temporarily override the schedule See page 11 Permanently override the schedule See page 12 This thermostat is ready to go 69 1969EFS 07 book Page 2 Tuesday November 26 2013 2 24 PM ...

Page 6: ...ode Fan Switch see page 7 On Fan runs all the time Auto Fan runs only when heating or cooling is taking place Press to adjust temperature Screen Lit for 12 seconds when you press any button Press to set clock day or schedule see pages 5 10 Press to override schedule and hold temperature see page 12 Press to run follow schedule see page 8 69 1969EFS 07 book Page 3 Tuesday November 26 2013 2 24 PM ...

Page 7: ...either of the temperature adjustment buttons once The setpoint temperature will appear for five seconds System status Cool On Cooling is activated Heat On Heating is activated Aux On Auxiliary heat is activated Low batterywarning see page 14 Setpoint indicator Appears when the setpoint temperature is displayed Clock Schedule period Permanent schedule override see page 12 Temporary schedule overrid...

Page 8: ...ay of the week Press the Run button to save the changes exit The changes are also saved if you do not press any button for 60 seconds NOTE The clock has lost its settings when the time display flashes If the thermostat is following the schedule it will use the temperature settings programmed for the Wake period of the weekdays until you readjust the clock Set the clock Set Time Set Day 69 1969EFS ...

Page 9: ...is off Heat System is in Heating mode Em Heat System is in Emergency Heat mode Only auxiliary heating can be activated The compressor is disabled This mode is available on the TH2210D model only CAUTION EQUIPMENT DAMAGE HAZARD Do not use Cooling mode when the outdoor temperature is below 50 F 10 C 69 1969EFS 07 book Page 6 Tuesday November 26 2013 2 24 PM ...

Page 10: ...Fan switch Use the Fan switch to select the fan operation Auto The fan runs only when heating or cooling is activated commonly used setting On The fan runs all the time 69 1969EFS 07 book Page 7 Tuesday November 26 2013 2 24 PM ...

Page 11: ...t its start time and its two temperature settings one when the thermostat is in cooling mode and another one when it is in heating mode The same settings are used every day from Monday to Friday and another set of settings are used for Saturday and Sunday For example you could program all four periods for the weekdays but only two periods Wake and Sleep for the weekends Using the schedule Wake Sta...

Page 12: ...y them Preprogrammed schedule settings Period Weekdays Weekends Start time Heat Cool Start time Heat Cool Wake 6 00 am 70 F 21 C 75 F 24 C 6 00 am 70 F 21 C 75 F 24 C Leave 8 00 am 62 F 16 5 C 83 F 28 5 C Return 6 00 pm 70 F 21 C 75 F 24 C Sleep 10 00 pm 62 F 16 5 C 78 F 25 5 C 10 00 pm 60 F 15 5 C 78 F 25 5 C 69 1969EFS 07 book Page 9 Tuesday November 26 2013 2 24 PM ...

Page 13: ...he heating mode place the switch in Heat Press the or button to set the temperature Press the Set button The start time of the next period will flash Repeat steps 2 through 6 for each of the remaining periods Once all adjustments are made press the Run button to save them and exit The changes are also saved if you do not press any button for 60 seconds Modifying the schedule The Wake period for th...

Page 14: ...rent period has been overridden The new temperature will be used until the next period begins NOTE Pressing or once will display the setpoint temperature To change the setpoint temperature press either button more than once Press the Run button if you wish to cancel the temporary setting before the beginning of the next period Temporary override of schedule 69 1969EFS 07 book Page 11 Tuesday Novem...

Page 15: ...the new temperature indefinitely The word Hold will appear on the screen Press the Run button if you wish to cancel the override and resume the schedule The word Hold will disappear and the thermostat will be set to the temperature programmed for the current period Permanent override of schedule 69 1969EFS 07 book Page 12 Tuesday November 26 2013 2 24 PM ...

Page 16: ... will come on before the set time so the temperature is 70 F 21 C by the time you wake at 6 a m Your thermostat has a feature that helps prevent damage to the compressor of your air conditioning or heat pump system Because damage can occur if the compressor is restarted too soon after shutdown this feature forces the compressor to wait 5 minutes before restarting During the wait time the message C...