background image

1)Non-contact and high-precision body temperature measurement; 

2)It can select ℃ or ℉; 

Setting method: press the "          "key for 8 seconds to switch in the 
startup state. 

3)Alarm value can be set (the default value of this product is 38℃) 

Setting method: the default is set; 
4)Beep prompt function (it can set to turn on or turn off the buzzer) 
Setting method: press the "          "key once to turn on the buzzer in 
the startup state; 
5)The LCD display with backlight can be used by users in darkness. 
Setting method: press the "          "key once to turn on the backlight in 
the startup state; press the "          " key for 8 seconds to convert to 
object test in the startup state; 

6)Automatic range selection; resolution is 0.1℃ (0.1℉)

7)The latest 32 measured data can be memorized and stored (press 
the up and down keys to check the latest 32 stored and measured 
data) 
8)Automatic data keeping and automatic shutdown 

 

 

 

 

 

 

 

 

 

 

 

  
 

 

 

 

 

 

 

 

 
 

Product Specification

 

  

Model: A66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jiangxi AICARE Medical Technology Co., Ltd.

 

 

Table of Contents

 

 

1. Description..............................................................................................
2. Safety Manual for Use........................................................................ 
3. Characteristics.......................................................................................
4. Other Instructions for Use................................................................
5. Notes before Use.................................................................................
6. Product Structure.................................................................................
7. Description of LCD Screen................................................................
8. Scope of Application and Contraindications of Products...... 
9. Technical Indicators.............................................................................
10. Operating Instructions for Use......................................................
11. Reference Value of Body Temperature.......................................
12. Advice.....................................................................................................
13. Care and Maintenance......................................................................
14. Instructions for Waste Disposal.....................................................
15. Symbol Description............................................................................
16. List of Product Accessories..............................................................

 
 

1
1
2
2
3
3
4
4
5
6
7
8
8
9
1 0
1 0

 

I. Description

 

 

 

II. Safety Manual for Use

 

Please read this manual carefully before using the infrared 

thermometer. 

 

The environment temperature when using this product is 

16℃ ~ 35℃.

Please do not place this product in an environment higher than 

50℃ or lower than 0℃.

Please do not place this product near charged objects to 

avoid electric shock.

 

Please do not use this product in an environment with relative 

humidity greater than 85%.

 

Please do not place this product too close to the electromagnetic 

range. (such as radio, mobile phone, etc.).

 

Please do not expose this product to the sun, or place it close to 

the stove, and not contact with water.

 

Please do not strike or drop this product, and do not use the 

product if it is damaged.

 

Sweat on forehead, hair, hat or scarf will affect the measuring 

accuracy.

 

Please confirm that the measuring distance is in the range 

of 5-10cm.

 

 

When forehead sweat or other reasons cause forehead temperature 

not to reflect the human temperature normally, please measure the 

human temperature from posterior earlobe. 

 

When cleaning is required, wipe the instrument surface gently 

with alcohol.

 

If the product has any problem, please contact with the distributor 

rather than repairing the product individually. It is forbidden to 

measure the body temperature.

 

when the environment temperature changes greatly.

 

 

-1- 

I I I .   C h a r a c t e r i s t i c s

I V .   O t h e r   I n s t r u c t i o n s   f o r   U s e

-2-

V. Notes before Use

 

 

Power On Self-checking

 

 

 

 

 

 

 
 

VI. Product Structure

 

 

 

 

 

 

①.Infrared sensor 
②.Liquid crystal display (LCD) screen 
③.Backlight on/off key 
④.Up button (view historical data) 
⑤.Down button (view historical data) 
⑥.Sound switch key 
⑦.Measuring switch 
⑧.Battery cover 
⑨.Handle

 

 

 

 

-3- 

Figure 1

VII. Description of LCD Screen

 

 

 

 

 

 

 
 

①.Body temperature mode (BODY) 
②.Digital reading 
③.Storage position 
④.Temperature ℃/F

 

 
 
 
 
 
 

VIII. Scope of Application and

Contraindications of Products

 

-4- 

Figure 2

IX. Technical Indicators

 

 

1. Basic parameters 

 

 

 

Display the accurate digits

 

0.1℃(0.1℉)

 

   

 

 

Storage temperature

 

-20-55℃

 

   

 

 

Operating environment temperature

 

16℃~35℃

 

   

 

 

Relative humidity

 

≤85%

 

   

 

 

Power

 

DC 3V(2 AAA batteries)

 

 

   

 

 

Specification

 

160*100*40mm 

   

 

 

Weight

 

100g 

   

 

 

Production date 

 

See the product certificate for details.

 

   

 

2. Measuring range

 

 

  

 

 

Model temperature measuring range in human body

 

32.0-42.9℃

 

  

 

 

Range of measuring distance

 

5-10cm  

  

 

 

Automatic shutdown

 

About 20s

 

  

 

3. Measuring accuracy

 

 

  

 

 

32.0

℃~

34.9

 

±0.3℃

 

  

 

 

35.0

℃~

42.0

 

±0.2℃

 

  

 

 42.1

℃~

42.9

 

±0.3℃

 

  

 

4. Service life 

The service life of the product is 40,000 times, and the product is valid 

for 5 years. 

5. Software release version

V1.0

 

 

 

-5- 

X. Operating Instructions for Use 

 

 

-6-

 

This product is a non-contact infrared thermometer that 

specializes in measuring the temperature of human forehead, 

and the measured temperature will be different according to the 

difference of human skin; different measured parts of human can 

result in different temperatures as  the exposed parts of the 

human are greatly affected by the environment temperature. 

Infrared thermometer is a thermometer specialized in measuring 
the human forehead, it is widely used in families, and this product 
cannot replace doctors' diagnosis. 

Aim at the target to be tested, press the measuring switch, and LCD 

will display all the numbers and characters of the self-checking and a 

self-checking screen will appear, as shown in Figure 1 below. This 

picture will be displayed for about 1 second.

After the self-checking is completed, a sound of “beep” will be 

heard, indicating that the power-on self-checking has been 

completed, and the temperature value of the tested target will be 

displayed on the LCD.

The product is mainly composed of an infrared sensor, a LCD screen, 
a button, a shell, a handle, a battery and a circuit board.

1. Scope of application of products 
The body temperature of the tested object is displayed by measuring the 
thermal radiation on the forehead. 
2. Contraindications of products 
1) Birth defects, congenital malformation, septic shock, circulatory failure and 
other diseases that may affect forehead temperature measurement seriously. 
2) Suffering from mental disorders. 
3) Suffering from serious heart, liver and kidney diseases. 

6. Working, storage and transportation environment requirements 
1) Working environment: 

Environment temperature: 16℃ ~ 35℃; 
Relative humidity: ≦85%; 
Atmospheric pressure: 70 kpa ~ 106 kpa 

Power: DC 3V(2 AAA batteries) 
2) Storage and transportation environment: 

Environment temperature:-20℃ ~+55℃; 
Relative humidity: 10% ~ 85%; 

No corrosive gas, well ventilated room. 
Transportation requirements must conform to regulations of the order 
contract, but severe impact, vibration and rain and snow splash during 
transportation must be prevented.

1.Battery instructions 

An indicating arrow on the ellipse is arranged at the bottom of the 

handle; please push the battery cover forwards lightly in the direction 

of the arrow with your hand here, and install the battery, so that it can 

be tested and used. 

Notes of battery installation and replacement: 

1) After the battery cover is opened, place the battery at the place 

where the battery is installed according to the positive and negative 

directions. Pay attention to the correct direction of the positive and 

negative electrodes. 

2) Wait for 10 minutes to warm up after first using or just placing the 

new battery; 

3) When the battery capacity is insufficient, the symbol will appear on 

the display screen, prompting to replace the new battery. Open the 

battery cover (see product structure ⑧) and pay attention to the 

positive and negative polarity when replacing the new battery. 

Incorrect placement may cause damage to the product. 

4) Please take out the battery when the product is not used for a long 

time to prolong its service life, and prevent the thermometer from 

being damaged due to leakage of battery liquid. 

2. Measuring steps of body temperature 

1) Aim the thermometer at the middle of forehead (above the 

eyebrows) and keep it vertical with a distance of about 5-10cm, and 

press the measuring switch to display the temperature immediately. 

Summary of Contents for A66

Page 1: ...Product Specification Model A66 Jiangxi AICARE Medical Technology Co Ltd ...

Page 2: ...re 7 Description of LCD Screen 8 Scope of Application and Contraindications of Products 9 Technical Indicators 10 Operating Instructions for Use 11 Reference Value of Body Temperature 12 Advice 13 Care and Maintenance 14 Instructions for Waste Disposal 15 Symbol Description 16 List of Product Accessories 1 1 2 2 3 3 4 4 5 6 7 8 8 9 1 0 1 0 ...

Page 3: ... hat or scarf will affect the measuring accuracy Please confirm that the measuring distance is in the range of 5 10cm When forehead sweat or other reasons cause forehead temperature not to reflect the human temperature normally please measure the human temperature from posterior earlobe When cleaning is required wipe the instrument surface gently with alcohol If the product has any problem please ...

Page 4: ...ers in darkness Setting method press the key once to turn on the backlight in the startup state press the key for 8 seconds to convert to object test in the startup state 6 Automatic range selection resolution is 0 1 0 1 7 The latest 32 measured data can be memorized and stored press the up and down keys to check the latest 32 stored and measured data 8 Automatic data keeping and automatic shutdow...

Page 5: ...tch and LCD will display all the numbers and characters of the self checking and a self checking screen will appear as shown in Figure 1 below This picture will be displayed for about 1 second After the self checking is completed a sound of beep will be heard indicating that the power on self checking has been completed and the temperature value of the tested target will be displayed on the LCD Th...

Page 6: ...ion of products The body temperature of the tested object is displayed by measuring the thermal radiation on the forehead 2 Contraindications of products 1 Birth defects congenital malformation septic shock circulatory failure and other diseases that may affect forehead temperature measurement seriously 2 Suffering from mental disorders 3 Suffering from serious heart liver and kidney diseases ...

Page 7: ...100 40mm Weight 100g Production date See the product certificate for details 2 Measuring range Model temperature measuring range in human body 32 0 42 9 Range of measuring distance 5 10cm Automatic shutdown About 20s 3 Measuring accuracy 32 0 34 9 0 3 35 0 42 0 0 2 42 1 42 9 0 3 4 Service life The service life of the product is 40 000 times and the product is valid for 5 years 5 Software release v...

Page 8: ...ent 1 After the battery cover is opened place the battery at the place where the battery is installed according to the positive and negative directions Pay attention to the correct direction of the positive and negative electrodes 2 Wait for 10 minutes to warm up after first using or just placing the new battery 3 When the battery capacity is insufficient the symbol will appear on the display scre...

Page 9: ...rature not to reflect the human temperature normally please aim at the posterior earlobe to measure the body temperature At the same time please ensure that there is no hair sweat cosmetics or hat covering etc 3 If the thermometer has not been used for a long time the environment temperature will be detected when it is used again and the startup time will be extended by 1 2 seconds 4 Human tempera...

Page 10: ...ile part of the instrument so it must be used carefully Please do not charge the non rechargeable battery and do not throw the battery into the fire Please do not expose the product to the sun or touch water 1 Product maintenance and cleaning 1 The probe part is the most precise part of the product and must be carefully protected 2 Do not clean the product by using corrosive detergent 3 Do not imm...

Page 11: ...than the measuring range or the measured temperature is lower than 32 in the human temperature measuring mode When the information Lo or Hi appears the following situations are for reference Direct disposal of electronic products and batteries in garbage cans will cause harm to the environment Please dispose them according to the local laws Don t throw the infrared thermometer in the garbage can a...

Page 12: ... This form is prepared according to SJ T 11364 2014 O indicates that the content of the hazardous substance in all homogeneous materials of the par is below the limit requirement specified in GB T 26572 X indicates that the content of the harmful substance in at least one homogeneous material of the part exceeds the limit requirement specified in GB T 26572 The hazardous substances shown in this f...

Page 13: ...cate This product meets the technical requirements after inspection and is qualified Product name Medical Infrared Thermometer Product model A66 Manufacturer Jiangxi AICARE Medical Technology Co Ltd Inspector ...

Page 14: ...rovince No 1 Building New Era Home Group Le an County Contact information 0794 6577516 Name of after sales service unit Jiangxi AICARE Medical Technology Co Ltd Contact information 0794 6577516 Address South Side of South Ring Road Le an County Fuzhou City Jiangxi Province No 1 Building New Era Home Group Le an County Date of Approval and Modification of Manual March 06 2020 ...

Reviews: