PPT
RS-485 (B)
RS-485 (A)
Case Ground
Power and Signal
Common
1
2
3
4
shield gnd.
-
B
A
Host Computer
RS-485 (B)
RS-485 (A)
DC Power
5.5 to 30 V
DC Power In
Voltage Output
5
6
Make all common
connections at this
end of the cable.
+
Common
0 to 5 VDC Out
PPT
Figure 6.3—Connection for RS-485 Operation and Analog Output
RS-232 Transmit
1
RS-232 Receive
Case Ground
Power and Signal
Common
DC Power In
Voltage Output
2
3
4
5
6
Make all common
connections at this
end of the cable
Battery
5.5 to 30V
Common
0 to 5 VDC Out
Figure 6.4—Connection for Analog Output and Battery Operation
Host Computer
RS-232 TD / RS-485 (B)
RS-232 RD / RS-485 (A)
Case Ground
Power and Signal
Common
DC Power In
PPT
Voltage Output
Actuator
or Valve
1
2
3
4
5
6
shield gnd.
Make all common
connections at this
end of the cable.
-
+
RS-232 Receive / RS-485 (B)
RS-232 Transmit / RS-485 (A)
Signal Ground
DC Power
5.5 to 30 V
Figure 6.5—PPT Conn
ection for Computer Operation
and User Controlled Analog Voltage Output
75