HR150B, HR200B PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS

5

68-0285

Fig. 4. Direct connection of supply air stream to furnace cold air return.

Fig. 5. Direct connection of ventilator supply air stream and exhaust air stream to furnace cold air return.

COLD AIR
RETURN

EXHAUST AIR FROM 
VARIOUS PARTS OF 
HOME (BATHROOMS 
IF REQUIRED; KITCHENS 
IF REQUIRED; ROOMS 
WITHOUT OPERABLE WINDOWS, 
AND POTENTIALLY BASEMENTS).

FORCED AIR
FURNACE

COMBUSTION 
OR ELECTRIC

M22722

RETURN
AIR

OUTDOORS

NOTES:

1.

2.

3.

4.

FURNACE BLOWER NEED NOT OPERATE TO PROVIDE GOOD AIR DISTRIBUTION/QUALITY WITH THIS SYSTEM.

IF FURNACE BLOWER OPERATION IS REQUIRED TO HELP DISTRIBUTE SUPPLY AIR:  RUN CONTINUOUSLY 
OR INTERLINK ELECTRICALLY (LOW VOLTAGE) USING OPTIONAL 32003248-001 BLOWER INTERFACE KIT.

NO SEPARATION REQUIREMENTS ARE NECESSARY BETWEEN DIRECT CONNECTION POINT AND FURNACE.

WEATHER-HOOD ARRANGEMENT IS FOR DRAWING ONLY.  6 FT (2m) MINIMUM SEPARATION REQUIRED, 
18 IN. (0.46m) ABOVE GRADE MINIMUM.

40 IN. (1m) MINIMUM

COLD AIR
RETURN

FORCED AIR
FURNACE

COMBUSTION 
OR ELECTRIC

M22723

RETURN
AIR

OUTDOORS

NOTES:

1.

2.

3.

4.

FURNACE BLOWER IS REQUIRED TO OPERATE WHEN VENTILATION IS REQUIRED.  
SET THE FURNACE BLOWER TO RUN CONTINUOUSLY, OR INTERLINK ELECTRICALLY 
(LOW VOLTAGE) USING OPTIONAL 32003248-001 BLOWER INTERFACE KIT.

MINIMUM SEPARATION OF 40 IN. IS REQUIRED BETWEEN THE TWO 
DIRECT CONNECTIONS.

EXHAUST AIR CONNECTION SHOULD BE UPSTREAM OF THE SUPPLY 
AIR CONNECTION TO PREVENT EXHAUSTING ANY FRESH AIR.

WEATHER-HOOD ARRANGEMENT IS FOR DRAWING ONLY.  6 FT.  (2 m) 
MINIMUM SEPARATION REQUIRED, 18 IN. (0.46m) ABOVE GRADE MINIMUM.

Summary of Contents for Perfect Window HR150B

Page 1: ...es ventilation that helps contractors meet ASHRAE 62 89 4 speed fan control Automatic economical built in frost control for operation to design temperatures of 40 F 40 C Easy to clean aluminum cross flow core Includes vibration isolation hardware and duct collars Insulated cabinet made of rugged steel Permanent washable prefilters Quiet operation Digital fan timer option on all models Contents App...

Page 2: ...not include normal manufacturing tolerances Therefore this unit might not exactly match the listed specifica tions Also this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed Color White Electrical Ratings Power Rating 220 Vac 50 Hz Consumption 0 8A at maximum speed Mounting Mount in condit...

Page 3: ...gh the ventilator to the outdoors Heat is transferred from one airstream to the other as the air passes through the opposite sides of the heat transfer core See Fig 2 Fig 2 Duct connections and airflow 14 3 4 375 33 5 8 854 19 483 SERVICE CLEARANCE 25 635 19 483 HR CONTROLS ALL DUCT CONNECTIONS ARE 6 150 DRAIN SPOUTS MOUNTING STRAP 4 M22700 WEIGHT 70 lb 32 kg SHIPPING WEIGHT 72 lb 33 kg Fresh Air ...

Page 4: ...l connections to and from the ventilator Separate outside intake and exhaust vents by at least 6 ft 2m NOTES Do not locate the fresh air vent where it blows directly onto occupants or the thermostat Do not locate the fresh air intake close to known sources of pollutants such as automobile exhaust a dryer vent or chimney smoke Ducting the supply outlet and or the exhaust inlet of the ventilator to ...

Page 5: ...ECTRICALLY LOW VOLTAGE USING OPTIONAL 32003248 001 BLOWER INTERFACE KIT NO SEPARATION REQUIREMENTS ARE NECESSARY BETWEEN DIRECT CONNECTION POINT AND FURNACE WEATHER HOOD ARRANGEMENT IS FOR DRAWING ONLY 6 FT 2m MINIMUM SEPARATION REQUIRED 18 IN 0 46m ABOVE GRADE MINIMUM 40 IN 1m MINIMUM COLD AIR RETURN FORCED AIR FURNACE COMBUSTION OR ELECTRIC M22723 RETURN AIR OUTDOORS NOTES 1 2 3 4 FURNACE BLOWER...

Page 6: ... can also be high levels of formaldehyde and other chemicals that were used in the building materials Running the ventilation system on high speed provides optimum indoor air pollutant reduction High speed also provides maximum moisture removal when the outside air contains less moisture than the inside air Typically during cold weather conditions Operating Damper Frost Control Some models have an...

Page 7: ...ts is recommended NOTE Removing door and core reduces the weight of the ventilator making it easier to lift into place Floor Mounting The mounting hardware included is not needed for floor mounting 1 Use 2 x 4 in wood pieces to build a frame to support the ventilator along the bottom edge The frame must hold the ventilator at least 10 in up from the floor to allow clearance for the drain line 2 Se...

Page 8: ...nnect the hot line to the interlock switch See Fig 9 To confirm correct polarity use voltmeter or test lamp to verify there is no power after the switch when the door is open Check between that point and ground on cabinet This process must be used because occasionally some dwellings are incorrectly wired Connect line voltage to the ventilator according to Fig 9 Honeywell recommends that a licensed...

Page 9: ...LTAGE M22720 SEE DEFROST DETAIL 1 FIELD INSTALLED HIGH VOLTAGE FIELD INSTALLED 12V LOW VOLTAGE RED 1 INSTALL 1 4 in FEMALE QUICK DISCONNECT TERMINAL TO HOT WIRE AND ASSEMBLE TO INTERLOCK SWITCH INSTALL 1 4 in FEMALE QUICK DISCONNECT TERMINAL TO NEUTRAL WIRE AND ASSEMBLE TO T11 TERMINAL INSTALL RING TERMINAL TO THE GROUND LEAD AND ASSEMBLE SECURELY TO THREADED STUD IN WIRING COMPARTMENT 2 3 2 T1 T2...

Page 10: ...e dampered back to match lower reading See Fig 10 Return unit to appropriate fan speed for normal operation STARTUP AND CHECKOUT After installation is complete check to be sure system is working correctly Turn speed selection knob to desired position to set continuous background ventilation rate Activate two wire control devices in system to make sure devices switch ventilator to High speed For op...

Page 11: ...gh conden sation appears on windows Dehumidistat is set too high Set dehumidistat lower Undersized ventilator hot tub indoor pool etc Cover pools and hot tubs when not in use Lifestyle of occupants Avoid hanging clothes to dry storing wood and venting clothes dryer inside Consider moving wood outside Moisture coming into home from crawl space not vented or heated Vent crawl space and place vapor b...

Page 12: ...ly installed Make sure water drains correctly from pan Table 3 Troubleshooting Guide Continued Symptom Cause Solution Item Number Fig 11 Description 1 Heat Transfer Core Aluminum with Plastic Frame 2 Blower Housing Kit 3 Condensate Pan Left or Right 4 Foam Prefilter Set of 2 5 Clip for Foam Prefilter 6 Drain Spout 7 Duct Collar Red 8 Duct Collar Blue 9 H Channel 13 1 4 in 10 Door Hinge Complete 11...

Page 13: ...HR150B HR200B PERFECT WINDOW FRESH AIR VENTILATION SYSTEMS 13 68 0285 Fig 11 Exploded view M22702 1 16 3 5 6 7 8 15 14 9 10 11 12 13 17 18 4 5 2 ...

Page 14: ...68 0285 14 ...

Page 15: ...15 68 0285 ...

Page 16: ...International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2005 Honeywell International Inc 68 0285 G H 02 05 ...

Reviews: