94(110) CONTROL
KEYPAD
7
7.3.6.4 Parameter
comparison
In the
Parameter comparison
submenu
(S6.4)
, you can compare the
actual parameter values
to the
values of your customised parameter sets and those loaded to the control keypad.
The comparison is performed by pushing the
Compare parameters
submenu
. The actual parameter values are first compared to those of the customised parameter Set1. If no
differences are detected a '0' is displayed on the lowermost line. But if any of the parameter values differ
from those of the Set1 the number of the deviations is displayed together with symbol
P
(e.g. P1
Æ
P5 = five
deviating values). By pressing the
Menu button right
once again you can still enter the pages where you
can see both the actual value and the value it was compared to. In this display, the value on the
(in the middle) is the default value and the one on the
(lowermost) is the edited
value. Furthermore, you can also edit the actual value with the
edit mode
that you
can reach by pushing the
Menu button right
once again.
In the same way, you can perform the comparison of the actual values to
Set2
,
Factory Settings
and
Keypad Set
.
Figure 7-13. Parameter comparison
C1
Î
C3
READY
READY
READY
0
enter
P1
Î
P6
P2.1.2= 50.0
READY
20.0 Hz
P2.1.2= 50.0
READY
20.0 Hz
ParamComparison
Set1
Set1
CONFIRM CHANGE
EDIT VALUE
OR