background image

 

TD1166 rev1003 

1 - 8 

NS1 Installation Guide 

 

 INTRODUCTION 

Thank you for using NS1 for your access control application. NS1 is a powerful access control system 
which can be used for single door access, as well as for connection to any type of on-line access control 
system. 

NS1 units can also be mounted in an RS485 network without the necessity of an external access control 
system. 

NS1 as a single door unit offers many possibilities such as: 

 

Access control 

 

Unlock option 

 

Day/Nightlock option (manual or automatic switching) 

 

Long range reader (up to 45cm) 

 

Optional use of PIN keypad 

 

Using an external relay (to prevent potential tampering) 

 

NS1 Manage software for stand-alone PC programming, event logging and user database 
maintenance 

REFERENCES 

Master card usage is described in the NS1 User Guide (TD1168). 

 

CONNECTIONS 

The NS1 uses 12 wire E111235 AWM STYLE 2560 60°C 30V low voltage computer cable. The 
connections are indicated below. 

Wire Stand-alone 

Magstripe 

(ABA) 

Wiegand 

Brown Extra 

Ground 

 

 

Violet 

Relay out (O.C) 

 

 

Black Ground 

 

 

Red 

Power (+11.5 … +12.5V DC) 

 

 

Yellow RS-485B 

in 

 

 

Blue 

RS-485B out - 

 

 

White RS-485A 

in 

 

 

Pink 

RS-485A out - 

 

 

Grey 

IO-1 Door contact input 

\ RDP output 

DATA 0 

Green 

IO-2 Ext. Night lock/Rex input 

\ RCP output 

DATA 1 

Grey/Pink 

IO-3 Forced entry output 

\ CLS output 

STROBE 

Red/Blue 

IO-4 Night lock enabled output 

\ Access input 

\ LED 

 

 

Summary of Contents for NS1

Page 1: ... of PIN keypad Using an external relay to prevent potential tampering NS1 Manage software for stand alone PC programming event logging and user database maintenance REFERENCES Master card usage is described in the NS1 User Guide TD1168 CONNECTIONS The NS1 uses 12 wire E111235 AWM STYLE 2560 60 C 30V low voltage computer cable The connections are indicated below Wire Stand alone Magstripe ABA Wiega...

Page 2: ...Yellow Pink Blue Grey Green Grey Pink Red Blue Violet Brown Red Black NOTES 1 The relay output is a 1A 30V open collector 2 With the NS1 only DC locks can be used when directly connected to the NS1 Alarm system Controller Next reader or Line Terminator External Clock Door contact Lock or external relay Power supply 12V DC ...

Page 3: ...8 9 0 A remote programmer can be used to configure the NS1 and do settings in the NS1 by bringing it into the RF field of the NS1 A programmed function may look like as follows The blank n in the function indicates an optional number An Installer Remote Programmer can set all functions of the NS1 In this Quick Guide configuring the NS1 Proximity Reader is described by means of a Remote Programmer ...

Page 4: ... up the NS1 2 Set the Lock Type 23 Different lock types can be set by entering the key sequence corresponding with the lock type See the following table for information Lock Type Key sequence Description Normally open 23 0 Normally closed 23 1 The settings normally open and normally closed are used when a lock is directly connected to the NS1 Coded signal 23 2 Coded signal is used to trigger an ex...

Page 5: ...eriod 3 Normal operation of the NS1 is resumed Figure 5 Setting Open Time out Period 4 Set Close Time out 12 The NS1 has a special timer that is intended to check whether the gate or door has been closed within a specific period of time This period of time is adjustable from 0 to 255 seconds The default value is 0 meaning that the function is disabled If you want to use the default value skip this...

Page 6: ...ther than the default one perform the steps indicated in Figure 7 1 Enter Program mode by presenting the Installer Remote Programmer 2 Enter Egress option 3 Normal operation of the NS1 is resumed Figure 7 Setting Egress Option 6 Set NS1 from Installer level to User level To prevent tamper alarms make sure the NS1 cover is in place If for any reason you need to go back to the installer level just p...

Page 7: ...ry If a forced entry situation occurs a continuous alarm will sound If required a burglar alarm can be triggered This option will only activate when a door contact is connected and the Close Time out is not set to zero The alarm can be deactivated by repeating the programming procedure for setting the Close Time out to zero The NS1 also has an anti tamper switch and alarm Tamper Protection The NS1...

Page 8: ...8 8 TD1166 rev1003 Honeywell Access Systems 135 West Forest Hill Avenue Oak Creek WI 53154 PH 414 766 1700 FAX 414 766 1798 www nciaccessworld com ...