CONFIGURING THE NS1 

The following steps describe how to configure the NS1. 

1.  Wake up the NS1 from sleep mode. 

When powering up the NS1 for the first time, the NS1 is in the Installer sleep mode. 

  This programmer will automatically become the Installer Remote Programmer. It is 

recommended to identify the Remote Programmer as the Installer by labelling it such. 

Figure 3 indicates how to wake up the NS1. 

1. Power on. (NS1 is in 

Installer Sleep mode.) 

2. Present a Remote 

Programmer in the RF 
field of the NS1. 

3. Normal operation of the 

NS1 is resumed. 

 

  

 

 

Figure 3 

Waking up the NS1 

2.  Set the Lock Type (23*). 

Different lock types can be set by entering the key sequence corresponding with the lock type. 
See the following table for information. 

Lock Type 

Key sequence 

Description 

Normally open 

23*0* 

Normally closed 

23*1* 

The settings “normally open” and “normally closed” are used when a lock 
is directly connected to the NS1. 

Coded signal 

23*2* 

Coded signal is used to trigger an external relay on the  Connection Unit 
(article NS1CU). The external relay offers a higher level of security. 

The default value is 23*0*. To set another value, take the steps indicated in Figure 4. 

1. Enter Program mode by 

presenting Installer Remote 
Programmer. 

2. Enter the choice for the Lock Type, where 

“n” is 1 or 2. 

3. Normal operation of the 

NS1 is resumed. 

 

 

 

 

Figure 4 

Setting Lock Type 

Summary of Contents for NS1

Page 1: ... of PIN keypad Using an external relay to prevent potential tampering NS1 Manage software for stand alone PC programming event logging and user database maintenance REFERENCES Master card usage is described in the NS1 User Guide TD1168 CONNECTIONS The NS1 uses 12 wire E111235 AWM STYLE 2560 60 C 30V low voltage computer cable The connections are indicated below Wire Stand alone Magstripe ABA Wiega...

Page 2: ...Yellow Pink Blue Grey Green Grey Pink Red Blue Violet Brown Red Black NOTES 1 The relay output is a 1A 30V open collector 2 With the NS1 only DC locks can be used when directly connected to the NS1 Alarm system Controller Next reader or Line Terminator External Clock Door contact Lock or external relay Power supply 12V DC ...

Page 3: ...8 9 0 A remote programmer can be used to configure the NS1 and do settings in the NS1 by bringing it into the RF field of the NS1 A programmed function may look like as follows The blank n in the function indicates an optional number An Installer Remote Programmer can set all functions of the NS1 In this Quick Guide configuring the NS1 Proximity Reader is described by means of a Remote Programmer ...

Page 4: ... up the NS1 2 Set the Lock Type 23 Different lock types can be set by entering the key sequence corresponding with the lock type See the following table for information Lock Type Key sequence Description Normally open 23 0 Normally closed 23 1 The settings normally open and normally closed are used when a lock is directly connected to the NS1 Coded signal 23 2 Coded signal is used to trigger an ex...

Page 5: ...eriod 3 Normal operation of the NS1 is resumed Figure 5 Setting Open Time out Period 4 Set Close Time out 12 The NS1 has a special timer that is intended to check whether the gate or door has been closed within a specific period of time This period of time is adjustable from 0 to 255 seconds The default value is 0 meaning that the function is disabled If you want to use the default value skip this...

Page 6: ...ther than the default one perform the steps indicated in Figure 7 1 Enter Program mode by presenting the Installer Remote Programmer 2 Enter Egress option 3 Normal operation of the NS1 is resumed Figure 7 Setting Egress Option 6 Set NS1 from Installer level to User level To prevent tamper alarms make sure the NS1 cover is in place If for any reason you need to go back to the installer level just p...

Page 7: ...ry If a forced entry situation occurs a continuous alarm will sound If required a burglar alarm can be triggered This option will only activate when a door contact is connected and the Close Time out is not set to zero The alarm can be deactivated by repeating the programming procedure for setting the Close Time out to zero The NS1 also has an anti tamper switch and alarm Tamper Protection The NS1...

Page 8: ...8 8 TD1166 rev1003 Honeywell Access Systems 135 West Forest Hill Avenue Oak Creek WI 53154 PH 414 766 1700 FAX 414 766 1798 www nciaccessworld com ...

Reviews: