Chapter 2 - Planning
2.6.12
Maximum Shock
Operating
Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 40 G for up to 2.3 ms.
Storage
Six consecutively executed shock pulses in the positive and negative x, y,
and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
2.6.13
Altitude
Operating
3048 m (10,000 ft). This value may be limited by the type and number of
options installed.
Maximum allowable altitude change rate is 457 m/min (1500 ft/min). (that
is 1 °F /167.64 meters that is -17.22 °C / 167.64 meters).
Storage
12,000 m (39,370 ft). Maximum allowable altitude
Change rate is 457 m/min (1500 ft/min).
2.6.14
External peripherals
Keyboard
Windows compliant USB (equivalent or better)
Mouse
USB (equivalent or better)
2.6.15
Drives
Hard
Drive
Tab 100 / Tab 200: 500 GB 7.2K RPM SATA 3 Gbps 3.5” Cabled Hard
Drive.
2.6.16
External ports
Serial
One DB-9 connectors
LAN
2 x RJ-45
SCSI External
None
USB
Front :Two Hi-Speed USB Hosts (One USB 2.0 and one USB 3.0).
Back :Total Six Hi-Speed USB Hosts (four USB 2.0 and two USB
3.0).
Video
1 VGA port
- 18 -