GasAlertMicro 5/PID/IR Battery Charger
[
English] Instruction Sheet
D5688/2 Page
4
Trimmed and folded dimensions: 4.125 (w) x 5.875 (H)
5.
Push the battery pack down, angle it towards the back of the
charger, and release. Refer to Figure 7. The battery pack sits
securely if inserted correctly.
Figure 7. Charging the Battery Pack without the Detector (Side)
The charger emits one beep and the LED lights red.
6.
Allow the battery to fully charge (approximately 3.5 hours).
The charging LED changes to green when charging is complete.
When the battery pack is removed from the charger, the LED
deactivates.
a
Warning
When replacing battery packs, ensure the GasAlertMicro 5 IR battery
pack is only inserted into the GasAlertMicro 5 IR detector. The IR
battery packs are not compatible with other Micro 5 models and
vice versa. Refer to the IR warning label located on the back of the
IR battery pack lid.
Troubleshooting
If a problem occurs, refer to the following solutions. If the problem persists,
contact
BW Technologies by Honeywell
.
Table 3. Troubleshooting Guide
Problem
Possible
Cause
Solution
The detector is not
inserted correctly in the
cradle.
Firmly insert the detector
into the cradle.
The battery pack is
above or below the
operating temperature.
Allow the battery pack time
to adjust to the specified
operating temperature
(approximately 1 hour).
The battery pack is
severely depleted.
Contact
BW Technologies
by Honeywell
The charge
LED does not
activate when
the detector is
inserted.
Damaged or defective
battery pack.
Contact
BW Technologies
by Honeywell
.
There is no
audible beep.
Internal damage to
battery or charger.
Contact
BW Technologies
by Honeywell
.
The battery is above or
below the operating
temperature.
Leave the battery in the
charger. When the battery
returns to room
temperature, charging will
begin.
The battery pack is
severely depleted.
Contact
BW Technologies
by Honeywell
.
There is an
audible beep,
but no charge.
Damaged or defective
battery pack.
Contact
BW Technologies
by Honeywell
.
Maintenance
a
Warning
No user-serviceable parts inside.
To maintain the charger in good operating condition, perform the following
basic maintenance as required.
•
Clean the exterior with a soft, damp cloth. Do not use solvents, soaps,
or polishes.
•
Do not immerse the charger in liquids.
Battery Pack Storage
When stored for extended periods of time, ensure that the battery pack is
fully charged and then recharged every 30 days.
Replacement Parts and Accessories
a
Warning
To avoid personal injury or damage to the charger, use only
the specified replacement parts.
Table 4. Replacement Parts and Accessories
Model No.
Description
Qty
M5-BAT01
GasAlertMicro 5 and GasAlertMicro 5
PID rechargeable battery pack
1
M5IR-BAT04
GasAlertMicro 5 IR rechargeable
battery pack
1
M5-C01-BAT01
*
GasAlertMicro 5 and GasAlertMicro 5
& PID cradle charger / battery pack kit
1
M5IR-C01-BAT04*
GasAlertMicro 5 IR cradle charger /
battery pack kit
1
*
Add suffix (-UK) for United Kingdom mains plug, (-EU) for European mains
plug, (-AU) for Australian mains plug.