Honeywell LYNXDM-GSM Installation And Setup Manual Download Page 2

 

- 2 -

 

System Features 

Feature 

LYNXDM-GSM LYNXDM-IGSM

 

Quick connection to compatible LYNXR-I series control panels 

x x 

 

Simple programming using a 7720P programming tool  

x x 

 

Reports fire, burglary, and status messages via wireless network  

x

 

Reports fire, burglary, and status messages via internet  

 

x

 

 

Allows uploading and downloading of control panel data via the wireless 
network. 

X x

 

Allows uploading and downloading of control panel data via internet. 

 X 

 

Provides 2-way communication with the control using ECP messaging 

x x

 

 

Sends reports in Contact ID format 

x x 

 

Supports two hardwire zone trigger inputs (zones 6 and 7) 

x x

 

 

Easy CAT-5 10 BaseT connection to a hub or router 

 x 

 

Installs behind firewalls without compromising network security 

 x 

 

Supports dynamic or static IP addressing 

 x 

 

Supports remote control of alarm system via Remote Services Feature 

x x 

* As a backup to the internet. 

The LYNXDM-GSM and LYNXDM-IGSM provide the following types of supervision and module fault detection: 

 

Network communication failure: In the event the AlarmNet network does not hear a supervisory message 
from the module within a specified time (“Supervision” option, 24 hours, 30 days, or none), AlarmNet 
notifies the central station of a communication failure. 

 

Communication path failure: In the event the module detects a communication path failure, the control 
panel can be notified of a trouble condition with the module after a specified time has elapsed. 

Remote Services Features 

 

The Remote Services Features can only be used with LYNXR-I Series controls Revision 16 or later.  Multi 
Mode (E-mail notification) is intended as a convenience for the user, and does not replace Central Station 
reporting of critical events (alarms, troubles, etc.). 

Remote Services allow the end user to communicate with their Security System remotely via several features. 
Availability of this service is controlled by the dealer via the web-based programming tool on the AlarmNet 
Direct website. Once enabled, the specific programming fields associated with these features can be 
programmed either remotely using the AlarmNet Direct website or locally using the 7720P Programming Tool. 
These new web services will allow users to: 

 

Receive e-mail and text message notification of system events (Multi-Mode feature) 

 

Access their security system from a computer via a website (Remote Access feature) 

 

Perform system functions and receive confirmations using text messages (SMS feature) 

 

INSTALLATION 

 

The incoming wiring can be routed through the opening in the rear of the back plate or through the wire 
troughs in the mount’s case back. A wire knockout is also provided in the desk mount front case.

 

 

Installing the desk mount 

1.  Route the incoming power, telephone and/or internet wiring through the appropriate openings in the 

mount’s rear case. 

2.  Route incoming power, telephone and communications, etc. wiring through the mount’s front case. 
3.   Proceed to Wiring the LYNXR-I or LYNXR-ISIA section.

 

 

Installing the wall mount 

1.  Locate the rear case over the mounting surface such that the opening in the case is aligned with the 

wire/cable access opening (in the mounting surface). 

 

If the wiring will be run externally, it should be routed through the wire troughs in the wall mount case back

 

Summary of Contents for LYNXDM-GSM

Page 1: ... GSM cellular network using GPRS These transmissions are sent to the Honeywell NOC and then forwarded to your Central Station exactly the same way as if they were received via the Internet If the Internet AND GPRS are both unavailable the LYNXDM IGSM will attempt to send the transmission via SMS also known as a text message If all three methods fail the module will attempt to deliver the alarm unt...

Page 2: ...YNXR I Series controls Revision 16 or later Multi Mode E mail notification is intended as a convenience for the user and does not replace Central Station reporting of critical events alarms troubles etc Remote Services allow the end user to communicate with their Security System remotely via several features Availability of this service is controlled by the dealer via the web based programming too...

Page 3: ...lade of a medium size screwdriver refer to Figure 2 2 Once these tabs have been released insert the screwdriver in the side of the case and release the side locking tabs by gently twisting DO NOT disconnect the ribbon cable from the terminal strip board Disconnect the cable only from the front assembly board 3 Carefully disconnect the ribbon cable from the front assembly leaving the ribbon cable c...

Page 4: ...CASE HOOKS TABS TURN OVER F O R E X T E R N A L A N T E N N A F O R E X T E R N A L A N T E N N A 5 0 O H M M M C X O N L Y 5 0 O H M M M C X O N L Y 77 20 P PR O G R AM M ER PO R T N O T 77 20 P PR O G R AM M ER PO R T N O T FO R TE LE PH O N E SE R VI C E U SE FO R TE LE PH O N E SE R VI C E U SE PR IM AR Y PO W ER 9 16 5 VA C PR IM AR Y PO W ER 9 16 5 VA C C U R R EN T 90 0m A PE AK 70 m A ST A...

Page 5: ... IGSM ONLY Figure 4 LYNXDM GSM LYNXDM IGSM Wire Routing Wiring the LYNXDM GSM LYNXDM IGSM 1 Install a jumper wire between terminals 2 and 3 on the communication modules s terminal strip 2 Connect the 4 wire communication cable to the communication module s terminal strip refer to Figure 5 3 If you are installing a LYNXDM IGSM connect the incoming cable DSL connector to the receptacle on the commun...

Page 6: ...na must be used 2 AMPS antennas such as the 7825 OC antenna cannot be used with this product External Antenna Connecting the external antenna to the port will automatically disconnect the internal antenna 1 Connect the external indoor antenna onto the LYNXDM GSM LYNXDM IGSM SMA connector 2 Adjust the antenna as required 09004 016 V0 TB 1 6 7 8 5 11 10 9 2 3 4 1 FOR EXTERNAL ANTENNA 50 OHM MMCX ONL...

Page 7: ... Levels V 2V 13V V 0V 1V RF Transceiver Type Tri Band GSM GPRS Class 10 Modulation GMSK Antenna Internal GSM quad band antenna 1 3 dBi gain Band Transmission Frequency MHz Transmit Power dBm Receive Frequency MHz Receive Sensitivity dBm Number of Channels Channel Spacing MHz Duplex Separation kHz GSM 850 824 849 33 869 894 107 124 200 45 GSM 1800 1710 1785 33 1805 1880 106 374 200 95 GSM 1900 1850...

Page 8: ...Service IP Internet Protocol IP Address A unique number consisting of four parts separated by periods sometimes called a dotted quad for example 204 17 29 11 assigned to every computer workstation connected to the Internet IP numbers can be static assigned and unchanging or dynamic assigned via DHCP at each and every startup ISP Internet Service Provider MAC Media Access Code located on the module...

Page 9: ...lation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed...

Page 10: ... 10 NOTES ...

Page 11: ... 11 NOTES ...

Page 12: ... 12 NOTES ...

Page 13: ... 13 NOTES ...

Page 14: ...ARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the produc...

Page 15: ...04 014 V0 ECP OUTPUT ECP INPUT FAULT OUTPUT GND 12V DC IN MESSAGE LED FAULT LED STATUS LED 7720P PROGRAMMER PORT PANEL DOWNLOAD PORT JUMPER PINS 2 3 TAMPER SWITCH MOUNTING HOLE 4 SIGNAL STRENGTH RSSI MODE AND STATUS INDICATOR SWITCH RJ 45 ETHERNET PORT LYNXDM IGSM ONLY NETWORK CONNECTIVITY LED DISPLAY LYNXDM IGSM ONLY SIGNAL STRENGTH RSSI MODE AND STATUS LEDs INTERNAL ANTENNA NOTE TERMINALS 1 7 8 ...

Page 16: ...2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2007 Honeywell International Inc www security honeywell com K14515V13Š K14515V1 8 07 Rev A ...

Reviews: