Honeywell LYNXDM-GSM Installation And Setup Manual Download Page 10

 

- 10 -

 

-NOTES- 

Summary of Contents for LYNXDM-GSM

Page 1: ... GSM cellular network using GPRS These transmissions are sent to the Honeywell NOC and then forwarded to your Central Station exactly the same way as if they were received via the Internet If the Internet AND GPRS are both unavailable the LYNXDM IGSM will attempt to send the transmission via SMS also known as a text message If all three methods fail the module will attempt to deliver the alarm unt...

Page 2: ...YNXR I Series controls Revision 16 or later Multi Mode E mail notification is intended as a convenience for the user and does not replace Central Station reporting of critical events alarms troubles etc Remote Services allow the end user to communicate with their Security System remotely via several features Availability of this service is controlled by the dealer via the web based programming too...

Page 3: ...lade of a medium size screwdriver refer to Figure 2 2 Once these tabs have been released insert the screwdriver in the side of the case and release the side locking tabs by gently twisting DO NOT disconnect the ribbon cable from the terminal strip board Disconnect the cable only from the front assembly board 3 Carefully disconnect the ribbon cable from the front assembly leaving the ribbon cable c...

Page 4: ...CASE HOOKS TABS TURN OVER F O R E X T E R N A L A N T E N N A F O R E X T E R N A L A N T E N N A 5 0 O H M M M C X O N L Y 5 0 O H M M M C X O N L Y 77 20 P PR O G R AM M ER PO R T N O T 77 20 P PR O G R AM M ER PO R T N O T FO R TE LE PH O N E SE R VI C E U SE FO R TE LE PH O N E SE R VI C E U SE PR IM AR Y PO W ER 9 16 5 VA C PR IM AR Y PO W ER 9 16 5 VA C C U R R EN T 90 0m A PE AK 70 m A ST A...

Page 5: ... IGSM ONLY Figure 4 LYNXDM GSM LYNXDM IGSM Wire Routing Wiring the LYNXDM GSM LYNXDM IGSM 1 Install a jumper wire between terminals 2 and 3 on the communication modules s terminal strip 2 Connect the 4 wire communication cable to the communication module s terminal strip refer to Figure 5 3 If you are installing a LYNXDM IGSM connect the incoming cable DSL connector to the receptacle on the commun...

Page 6: ...na must be used 2 AMPS antennas such as the 7825 OC antenna cannot be used with this product External Antenna Connecting the external antenna to the port will automatically disconnect the internal antenna 1 Connect the external indoor antenna onto the LYNXDM GSM LYNXDM IGSM SMA connector 2 Adjust the antenna as required 09004 016 V0 TB 1 6 7 8 5 11 10 9 2 3 4 1 FOR EXTERNAL ANTENNA 50 OHM MMCX ONL...

Page 7: ... Levels V 2V 13V V 0V 1V RF Transceiver Type Tri Band GSM GPRS Class 10 Modulation GMSK Antenna Internal GSM quad band antenna 1 3 dBi gain Band Transmission Frequency MHz Transmit Power dBm Receive Frequency MHz Receive Sensitivity dBm Number of Channels Channel Spacing MHz Duplex Separation kHz GSM 850 824 849 33 869 894 107 124 200 45 GSM 1800 1710 1785 33 1805 1880 106 374 200 95 GSM 1900 1850...

Page 8: ...Service IP Internet Protocol IP Address A unique number consisting of four parts separated by periods sometimes called a dotted quad for example 204 17 29 11 assigned to every computer workstation connected to the Internet IP numbers can be static assigned and unchanging or dynamic assigned via DHCP at each and every startup ISP Internet Service Provider MAC Media Access Code located on the module...

Page 9: ...lation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed...

Page 10: ... 10 NOTES ...

Page 11: ... 11 NOTES ...

Page 12: ... 12 NOTES ...

Page 13: ... 13 NOTES ...

Page 14: ...ARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the produc...

Page 15: ...04 014 V0 ECP OUTPUT ECP INPUT FAULT OUTPUT GND 12V DC IN MESSAGE LED FAULT LED STATUS LED 7720P PROGRAMMER PORT PANEL DOWNLOAD PORT JUMPER PINS 2 3 TAMPER SWITCH MOUNTING HOLE 4 SIGNAL STRENGTH RSSI MODE AND STATUS INDICATOR SWITCH RJ 45 ETHERNET PORT LYNXDM IGSM ONLY NETWORK CONNECTIVITY LED DISPLAY LYNXDM IGSM ONLY SIGNAL STRENGTH RSSI MODE AND STATUS LEDs INTERNAL ANTENNA NOTE TERMINALS 1 7 8 ...

Page 16: ...2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2007 Honeywell International Inc www security honeywell com K14515V13Š K14515V1 8 07 Rev A ...

Reviews: