Honeywell Lynx Plus Series Installation And Setup Manual Download Page 29

Lynx Plus Series Installation and Setup Guide

 

- 29 -

 

Data Field Descriptions 

    

    54 

54 

54 

54     

LACK 

LACK 

LACK 

LACK         OF 

OF 

OF 

OF         USAGE

USAGE

USAGE

USAGE    

 

Lack of Usage Notification

  

If enabled, notifies the central station if an end user is not operating their security 
system by sending a System Inactivity report 654.  The report will be sent only to the 
Primary phone number and only if Contact ID® format was selected. 

Note:

 The report will follow the 

49 = 0 rules, no matter which selection was made in 

49. 

SELECTIONS 

0 = Disabled 
1 = 1 day 

2 = 7 days  
3 = 27 days

4 = 90 days  
5 = 180 days 

6 = 365 days 
 

Note

: There is no local annunciation indicating that this report has been sent to the Central 

Station.

 

Field 

55: 

If AAV is enabled in 

91, depending on Communication Channels programmed in 

55, only the Reporting 

options from the table below are available. They should be programmed as described in Dynamic Signaling (field 

77). If 

AAV is disabled in field 

91, reporting option 5 is not available. 

 

If Follow Me System of Pager features are selected, AAV will not be available even if enabled in 

91 UNLESS 

option 5 is selected in 

55 (Radio only). If option 5 is selected in 

55, AAV will be established on the primary 

channel because Follow me System and Pager are not available on the radio’s audio channel.

 

The following table shows the only valid combinations of communication channels and reporting options. It is the 
responsibility of the installer to ensure that a valid combination is programmed. 

Reporting Option 

AAV 

Enabled? 

55 Communication Channel  

Primary Phone only 

Y/N 

0 = Telco Line only (no radio) 

(see Note 1)

 

Redundant reports to both channels 

Y/N 

1 = LRR/IP (Digital Communication only) and Telco Line 

(see Note 1)

 

Primary Phone is the preferred channel 

Y/N 

1 = LRR/IP (Digital Communication only) and Telco Line  

(see Note 1)

 

LRR/IP is the preferred channel 

Y/N 

1 = LRR/IP (Digital Communication only) and Telco Line 

(see Note 1)

 

LRR/IP Only 

3 = LRR/IP (Digital Communication only) (no Telco Line) 

(see Notes 2 & 3)

  

 

5 = LRR/IP (Digital Communication w/AAV) (Telco Line connections for 2-way 

voice session only, if applicable) 

(see Notes 2, 3, 4)

 

 

NOTES 

1.  AAV mode can be established only on Telco Line. 
2.  Follow me System and Follow me Reminder and Pager features are not supported. These features will not work if 

selected in 

49. 

3.  Speaker Phone and Remote Phone Access are not available. These features should be disabled in 

47 and 

91. 

Download over the Phone Line feature is also unavailable. 

4.  AAV mode can be established only on LRR/IP (Digital Communication with AAV Capabilities) 

Legend 

LRR/IP (Digital Communication only) = Digital GSM Communication Channel 

LRR/IP (Digital Communication with AAV) = GSM Communication Channel with voice capabilities (a radio with voice capabilities is required 

to use the voice capabilities) 

Telco Line = Land Phone Line 

    

    55 

55 

55 

55     

REPORT 

REPORT 

REPORT 

REPORT         CHANNELS

CHANNELS

CHANNELS

CHANNELS    

 

Reporting Channels 

This option is used to enable/disable Central Station reporting via the LRR/IP 
Communications Device (See Field 

77).  Upload/ download via the Internet IP module 

is not affected by this entry. The option specifies the channel that the control will use 
when sending reports to the Central Station (Follow Me Phone and Pager). Select some 
or all channels as required. 

IMPORTANT NOTE: 

Make sure that selected channels are physically available and 

functional. 

SELECTIONS 

0 = Telco Line (no Radio) 

1 = LRR/IP(Digital Communication only) and Telco Line 
3 = LRR/IP (Digital Communication only) (no Telco Line) 
5 = LRR/IP (Digital Communication with AAV) (Telco Line Connections for 2-way voice 
session only, if applicable)

 

Summary of Contents for Lynx Plus Series

Page 1: ...allation and Setup Guide Installation and Setup Guide Installation and Setup Guide BYPASS NO DELAY RECORD TEST FUNCTION STATUS VOLUME PLAY CODE LIGHTS ON LIGHTS OFF CHIME ESCAPE ADD DELETE SELECT OFF STAY 1 3 2 AWAY AUX 4 6 5 ARMED READY 7 9 8 0 800 03857V1 12 09 Rev A ...

Page 2: ...m in the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical appliances such as portable heaters air conditioners or humidifiers are used Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet 12 meters long Install smoke detectors in any room where an alarm control is located or in any room whe...

Page 3: ...E 47 83 ENHANCED SEQUENTIAL MODE 49 84 ASSIGN ZONE VOICE DESCRIPTORS 52 85 RECORD CUSTOM VOICE DESCRIPTORS 54 REMOTE PROGRAMMING CONTROL DOWNLOADING 55 SYSTEM OPERATION 56 TESTING THE SYSTEM 62 SYSTEM COMMUNICATION 63 TROUBLESHOOTING GUIDE 65 PROGRAMMING DEFAULT TABLES 67 LYNX PLUS CONTROL DEFAULTS 67 LYNXSIA PLUS CONTROL DEFAULTS 69 REGULATORY AGENCY STATEMENTS 73 LIMITATIONS OF THIS SYSTEM STATE...

Page 4: ... 4 ...

Page 5: ...ces 1 Hardwire zone Up to 24 Wireless zones 5800 Series transmitters Up to 16 Wireless button zones Up to 8 Powerline carrier devices Supports wireless keypads Communication Ademco Low Speed Sescoa Radionics Ademco Express Ademco Contact ID Internet central station communication GSM cellular central station communication Two way voice communication Supports AlarmNet remote services Alarm Output Bu...

Page 6: ... case and allow you to make the wiring connections 6 After all wiring connections have been made snap the front case and back case closed and ensure that the control is secured by the locking tabs BACK CASE FRONT CASE 1000 300 009 V1 ROTATE FRONT CASE UPWARD TO RELEASE HOOKS MOUNTING HOOKS LOCKING TABS Desktop Mounting For desktop mounting the optional mounting base model LYNXPLUS DM purchased sep...

Page 7: ... is electrically connected and secured AC Power Outlet Ground Available from 3 prong 120VAC power outlets only To test the integrity of the ground terminal use a three wire circuit tester with neon lamp indicators such as the UL Listed Ideal Model 61 035 or equivalent available at most electrical supply stores a Connect terminal 1 to a good earth ground 2 Make Phone Line Connections For local or f...

Page 8: ...EOLR supervised zone that supports both open circuit and closed circuit devices and has a response time of 350msec Maximum zone resistance 300 ohms plus EOLR Note The hardwire zone cannot be used as a fire or CO zone a Connect sensors contacts to the hardwired zone terminals 6 and 7 Refer to the Summary of Connections diagram b Connect closed circuit devices in series in the high side of the loop ...

Page 9: ...uring Long Range Radio and Internet Communication Devices 1 Enable the communications device in programming field 55 and configure alarm reporting and module supervision in programming field 77 2 Program the device as required using the 7720P programmer refer to the Installation Instruction for the device that you are installing Note that the device address must be set to 3 The device must be regi...

Page 10: ...ng for Coverage Waiting for signal Try again in a few minutes If no signal persists move unit for better signal level check all connections and SIM activation GPRS GPRS Service availability where Y GPRS is available N GPRS is Not available REG Registration status from radio module where N Not Registered contact AlarmNet H Registered Home functioning normally S Searching wait or move unit to anothe...

Page 11: ...itions If the battery is missing or a low battery condition is detected a low battery message is displayed and a report is sent to the central station In addition the system will beep once every 45 seconds to audibly indicate a low battery condition press any key to stop the beeping AC Power and Rechargeable Backup Battery Connecting AC Power and backup battery 1 Connect wires from the K10145WH or...

Page 12: ...ver 2 Remove the screw that secures the battery retainer 3 Remove the battery retainer and disconnect the battery pack connector from the receptacle on the PC board 4 Remove the battery pack from the back plate 5 Install a replacement battery pack P N LYNXRCHKIT SC LYNXRCHKIT HC or LYNXRCHKIT SHA into the back plate 6 Install the battery retainer 7 Secure battery retainer with the provided screw a...

Page 13: ...premises 5804 5804BD 5804BDV and 5804E each transmitter is supervised by a check in signal that is sent to the receiver at 70 90 minute intervals If at least one check in is not received from each supervised transmitter within a 12 hour period the missing transmitter number s and FAULT will be displayed Additionally the panel will beep once every 45 seconds until acknowledged The supervision for a...

Page 14: ... two button panic pairs may be programmed for any 24 hour alarm response wireless keypads e g 5828 5828V keypads that have a two second delay on the special function keys or two button panic pairs built in keypad s two button panic pairs Go No Go Test Mode 5804E encrypted High Security devices must be activated while the system is in Go No Go Test Mode Refer to the transmitter s installation instr...

Page 15: ...ra ENROLL AS RF 5800CO ENROLL AS RF 5801 ENROLL AS UR OR RF 5800SS1 ENROLL AS RF 5800RL SET HOUSE ID LOOP 3 LOOP 1 LOOP 1 LOW SENSITIVITY LOOP 2 HIGH SENSITIVITY LOOP 3 TEMP LOOP 4 TAMPER LOOP 1 HIGH SECURITY LOOP 2 STANDARD SECURITY LOOP 3 TILT MODE LOOP 4 TAMPER LOOP 1 LOW SENSITIVITY LOOP 2 HIGH SENSITIVITY LOOP 3 TEMP LOOP 4 TAMPER LOOP 1 LOOP 2 LOOP 4 YOU MUST ENROLL THIS BUTTON 5849 ENROLL A...

Page 16: ...de 4112 800 to enter Expert Programming mode OR enter Installer Code 4112 888 to enter Voice Prompt Programming mode This method is disabled if Program mode is exited using 98 If a different Installer Code has been programmed use that code to enter the Programming mode 3 Upon entering programming mode the control will initially display Entering Programming Mode 4 Once you have entered the Program ...

Page 17: ...ptors will be announced whenever the system announces an event involving a zone 85 Record Custom Voice Descriptors Interactive menu mode used to record custom descriptors for use with each zone 96 Initialize Download ID and Subscriber Account Number for Downloading Entering 96 resets all subscriber account numbers and CSID in preparation for an initial download Loading Factory Defaults If a defaul...

Page 18: ...provides an instant alarm if the entry exit zone is not violated first and protects an area in the event an intruder has hidden on the premises before the system is armed or gains access to the premises through an unprotected area Zone Characteristics Delayed alarm using the programmed entry exit time if entry exit types 01 or 02 or interior with delay type 10 zone is faulted first Instant alarm i...

Page 19: ...ovided If any other fire zone is faulted during the 30 second delay window a fire alarm is immediately provided for that zone An alarm for original fire zone will also be provided if that zone is still faulted afterward If there are no fire alarms after the 30 second delay expires the system will open a 60 second window If any fire zone is faulted during that window a fire alarm will immediately b...

Page 20: ...tem Operation section for procedure Note LynxSIA Plus does not allow duplication of Installer code If a duplicate code is entered the entry is rejected and LYNX issues single long beep indicating rejection The old installer code remains unchanged SELECTIONS Enter 4 digits 0 9 21 21 21 21 QUICK QUICK QUICK QUICK ARM ARM ARM ARM ENABLE ENABLE ENABLE ENABLE Quick Arm Enable If enabled security code i...

Page 21: ...lay the time 30 30 30 30 DST DST DST DST WEEK WEEK WEEK WEEK STR STR STR STR END END END END Daylight Savings Time Start End Month Enter the appropriate start and end weekend of the month SELECTIONS 0 disable 4 fourth weekend 1 first weekend of month 5 last weekend 2 second weekend 6 next to last 3 third weekend 7 3rd from last 31 31 31 31 SINGLE SINGLE SINGLE SINGLE ALARM ALARM ALARM ALARM SND SN...

Page 22: ... maximum of 60 seconds SIA Exit Delay must be set to a minimum of 45 seconds Lynx Plus SELECTIONS LynxSIA Plus SELECTIONS Entries from 45 97 00 99 exit delay in seconds Entered Value Exit Delay in Seconds 45 96 97 45 96 120 35 35 35 35 ENTRY ENTRY ENTRY ENTRY DEL DEL DEL DELAY AY AY AY 1 1 1 1 Entry Delay 01 The system will wait the time entered before sounding alarm upon entering if system is not...

Page 23: ... The ding only sounds when control is Armed Away or disarmed after being Armed Away If Option 1 is selected confirmation of arming is provided by a 1 2 second sounder ding that sounds when closing report is sent or at the end of exit delay If Option 2 is selected the external sounder ding occurs immediately after arming from an RF keypad Note If LynxSIA Plus is armed by RF button key fob a confirm...

Page 24: ...AV is used primary Field 41 and secondary Field 42 phone numbers should be preceded with the call waiting disable command Otherwise there is the possibility of connection of the third party to Lynx Plus Series during AAV mode The PABX phone number entered in field 40 is not dialed on GSM IP Digital Communication with AAV However it is used for dialing on Telco Line 40 40 40 40 PABX PABX PABX PABX ...

Page 25: ... used Exit field by pressing if only 3 digits are used See blank Programming Form for examples of account number entries Enter digits 0 9 11 B 12 C 13 D 14 E or 15 F 43 43 43 43 PRIMARY PRIMARY PRIMARY PRIMARY ACC ACC ACC ACCOUN OUN OUN OUNT T T T Primary Subscriber Account Number Enter the primary subscriber account number To clear entries from field press 43 SELECTIONS Enter a 4 or 10 digit acco...

Page 26: ...l Wait Cancel is disabled in Field 47 and Call Waiting Disable command is entered in Field 40 this will prevent successful communication to the central station when used on a non call waiting line Note PABX number and operation of the control panel with a PBX system cannot be used if the Call Waiting Cancel option has been enabled in Field 47 Lynx Plus SELECTIONS Central Dialing Mode Station Pulse...

Page 27: ...GSMVL refer to Field 55 notes for additional information Pager Report Format Options 6 9 send reports to the primary phone number in a format defined in Field 48 and send reports to a pager which has its phone number entered as the secondary phone number in Field 42 The pager report is a 7 digit code with optional 16 digit prefix For an explanation of the pager format refer to the User Guide Follo...

Page 28: ... 8 silent panic audible alarm auxiliary alarm which are always sent as soon as they occur SIA The burglary abort window must be set to a minimum of 15 seconds The sum of the burglary abort window entered in 50 and the entry delays entered in either Field 35 or 36 should not exceed 1 minute Note The LynxSIA Plus control validates the data entered in this field If the selection is not valid the cont...

Page 29: ...ary Phone is the preferred channel Y N 1 LRR IP Digital Communication only and Telco Line see Note 1 LRR IP is the preferred channel Y N 1 LRR IP Digital Communication only and Telco Line see Note 1 LRR IP Only N 3 LRR IP Digital Communication only no Telco Line see Notes 2 3 Y 5 LRR IP Digital Communication w AAV Telco Line connections for 2 way voice session only if applicable see Notes 2 3 4 NO...

Page 30: ... Delay Reset occurs only once during an armed period LynxSIA Plus SELECTIONS Value Cancel Alarm Display Auto Stay Arming Exit Time Restart Reset 0 Disabled Disabled Disabled 1 Disabled Disabled Enabled 2 Disabled Enabled Disabled 3 Disabled Enabled Enabled 4 Enabled Disabled Disabled 5 Enabled Disabled Enabled 6 Enabled Enabled Disabled 7 Enabled Enabled Enabled 58 58 58 58 RF RF RF RF J J J JAM A...

Page 31: ... Contact ID format has been programmed the message will contain the zone number and error code 374 Trouble Exit Error If 4 2 format is used the digit entered in this field will be sent followed by the second digit of the programmed alarm code for that zone If 3 1 or 4 1 format is used only the digit entered in this field will be sent This message will go to the Primary Phone Number No restore mess...

Page 32: ...ee notes above This report is sent in the event that a wireless transmitter low battery condition exists Field 68 69 LynxSIA Plus Only The control validates the data entered in fields 68 69 If the selection is not valid the control will emit a single long beep indicating that the selection has been rejected The control replaces the selection with the default value which is displayed on the keypad ...

Page 33: ...device can communicate via AlarmNet GSM IP or Cellular communications devices Secondary phone is not affected by dynamic signaling scheme Two programming options are used to define dynamic signaling behavior Field 55 is used to enable disable the LRR IP communications device and allows it to supervise the communications module The two digit option programmed in Field 77 defines how dynamic signali...

Page 34: ...ons Dynamic Signaling Delay cannot exceed 15 sec If Primary Phone is used as a Preferred Channel duplicate reports may sent SELECTIONS 1st Entry delay before switching Central Station reporting path 0 Redundant reporting on dialer and LRR IP comm device 1 15 seconds 2 30 seconds 3 45 seconds 4 60 seconds 5 75 seconds 6 90 seconds 7 105 seconds 8 120 seconds 9 135 seconds 10 150 seconds 11 165 seco...

Page 35: ...in field 87 For an explanation of the pager format refer to the User Guide 2 Verify that the pager supports and characters before using them Some pagers require an additional delay pause in order to receive the entire message SELECTIONS Enter up to 16 digits that will appear in front of the 7 digit pager message Enter 11 for Enter 12 for Enter 13 for 2 second pause 89 89 89 89 EVNT EVNT EVNT EVNT ...

Page 36: ...ifferent features in the Lynx Plus and LynxSIA Plus controls Please be sure that you use the correct field for the control being installed 92 92 92 92 REPS REPS REPS REPS ARM ARM ARM ARMED ED ED ED PER PER PER PER This field applies only to the Lynx Plus control Number of Reports In Armed Period This field applies only to the Lynx Plus control This option can be used to limit the number of message...

Page 37: ...igits flexible DOWNLOAD INFORMATION 94 95 94 94 94 94 DOWNLOAD DOWNLOAD DOWNLOAD DOWNLOAD PHONE PHONE PHONE PHONE Download Call Back Phone Number This is the phone number the control will use to call back the downloading computer Do not fill unused spaces End field by pressing To clear entries from field press 94 SELECTIONS Enter up to 20 digits as follows 0 9 11 for 12 for 13 for a pause 95 95 95...

Page 38: ...s inactive Press any field number to go to that field SELECTIONS 00 Exit Zone Programming 01 Hardwire Zone 02 25 RF zones only 26 41 Button zones only 92 Duress 95 96 99 Panic zones b ZONE ZONE ZONE ZONE TYPE TYPE TYPE TYPE Zone Type Each zone must be assigned to a 2 digit zone type which defines the way in which the system responds to faults in that zone Press to advance to the next field or to r...

Page 39: ...ng At the end of the time out the system returns to the INPUT TYPE prompt d If enrolled the loop number and LEARNED are displayed 2 Once encrypted high security devices have been enrolled they must be activated Refer to the device s Installation Instructions to activate the High Security Mode RF Learning For BR type devices device type 5 2 transmissions 2 key depressions at least 5 seconds apart w...

Page 40: ...mission is received that matches the serial number and loop number entered the system will confirm the reception by announcing the Voice Descriptor for the zone if programmed followed by three beeps and a C will appear on the display indicating the received serial number and loop number have been confirmed No further transmissions will be received Delete serial number The serial number can be dele...

Page 41: ...never the system announces status for that zone SELECTIONS 0 skip to next zone A 1 enter descriptor mode existing descriptor for this zone will be announced I II Id Note System displays 2 digit selection alpha descriptor OR 99 No selection Descriptor 1 This prompt is used to enter a Voice Descriptor Enter 2 digit vocabulary index number of first descriptor word for this zone Use the 6 or 8 key to ...

Page 42: ...ne To change the entered index number before pressing 6 or 8 simply press desired 2 digit vocabulary index number If descriptor 2 is not desired enter 99 blank then press 8 to return to zone number prompt see 84 Assign Zone Voice Descriptors section for vocabulary index SELECTIONS Enter 2 digit vocabulary index number of first descriptor word for this zone 6 accept word and advance to descriptor 2...

Page 43: ... listed below and in the Programming Powerline Carrier Devices paragraph that follows ALARM Device activates upon any alarm in an assigned zone in the zone list FAULT Device activates upon any opening or short in an assigned zone in the zone list TROUBLE Device activates upon any trouble condition in an assigned zone in the zone list NOT USED Device action is not dependent upon one of the above ev...

Page 44: ...lable entries The right most column provides a further explanation of the entries Note Entering a number other than one specified will give unpredictable results ZT16 is only available on the LynxSIA Plus version of the control panel 80 80 80 80 DEVICE DEVICE DEVICE DEVICE PROG PROG PROG PROG MENU MENU MENU MENU Powerline Carrier Device Programming Entering 0 exits mode upon which this prompt blin...

Page 45: ...eing programmed see table that follows Choices for zone types 00 Not Used 07 24 Hr Audible 01 Entry Exit 1 08 24 Hr Aux 02 Entry Exit 2 09 Fire without verification 03 Perimeter 10 Interior w Delay 04 Interior Follower 14 Carbon Monoxide 05 Trouble Day Alarm Night 16 Fire with verification SIA Only 06 24 Hr Silent 24 Silent Burglary Choices for system operation 20 Arming Stay 38 Chime 21 Arming Aw...

Page 46: ...P the device action enter the appropriate 2 digit code see the ZT choices listed above If not enter 00 The display then returns to the DEVICE NUMBER prompt A so that you can enter the next device number to be programmed or enter 0 0 to end device programming SELECTIONS 01 58 zone type to stop this device action select only those that are applicable 00 zone type not used for this device continue re...

Page 47: ...mpt below Entering 0 exits mode upon which this prompt blinks indicating the mode is inactive SELECTIONS 0 exit mode 1 enter mode A01 A01 A01 A01 ZONE ZONE ZONE ZONE LIST LIST LIST LIST NUMBER NUMBER NUMBER NUMBER Zone List Number Enter the Zone List Number 01 02 or 03 to program or 00 if no zone lists are used Note Use Zone List 3 for Chime by Zone feature SELECTIONS 01 03 zone list number to be ...

Page 48: ...en deleting a zone s from the zone list if the selected zone has a Voice Descriptor programmed upon deletion it will be announced as a confirmation that it has been deleted After all zones to be deleted are entered enter 00 to return to the ZONE LIST NUMBER prompt so that another list can be programmed if desired SELECTIONS delete zone and enter next zone to be deleted 00 delete zone and return to...

Page 49: ...ode 4 button type keys will always be enrolled simultaneously They will be stopped at the 4 button boundaries of 26 30 34 and 38 provided the zone is free of a serial number If the first zone of the key has a serial number enrolled the remaining keys cannot be programmed in sequential mode In addition if the zone has not been set up duplicate loop missing zone type etc only entries 0 skip to the n...

Page 50: ...al number loop entry When the last zone has been entered the display will remain on that zone To exit this mode and return to data field program mode enter 00 at the ZONE NUMBER prompt When all zones have been programmed test each zone using the system s Test mode Do not use the Transmitter ID Sniffer mode for this since it will only check for transmission of one zone on a particular transmitter a...

Page 51: ...igits are entered the keypad will emit a single long beep and return to the 1A prompt without displaying the L If more than 7 digits have been entered the first 6 digits will be saved along with the last digit that was entered entering 123456789 yields the serial number 1234569 Note The system will return to prompt 1A if an entry is not made within 52 seconds SELECTIONS Enter transmitter s 7 digit...

Page 52: ...efore pressing 6 or 8 simply press desired 2 digit vocabulary index number If descriptor 1 is not desired enter 99 blank then press 8 to return to zone number prompt SELECTIONS Enter 2 digit vocabulary index number of first descriptor word for this zone 6 accept word and advance to descriptor 2 descriptor 2 will be announced 8 accept word and advance to prompt A for next zone Press any other key t...

Page 53: ...67 SILENT POLICE 68 SIX 69 SLIDING 22 SMOKE 23 SOUTH 24 STORAGE 85 SYSTEM T 25 THIRD FLOOR 75 THREE 76 TRANSMITTER 77 TWO U 78 UPSTAIRS 26 UTILITY 79 UTILITY ROOM W 27 WEST 80 WINDOW Y 28 YARD Z 81 ZERO 86 ZONES 29 1st 30 2nd 31 3rd 70 Custom Word 1 71 Custom Word 2 72 Custom Word 3 73 Custom Word 4 74 Custom Word 5 99 Blank for erasing a previously programmed word SYSTEM WORDS AC LOSS ARMED AWAY ...

Page 54: ... blinks indicating the mode is inactive SELECTIONS 0 exit mode 1 enter mode A A A A CUSTOM CUSTOM CUSTOM CUSTOM DESC DESC DESC DESC Custom Descriptor Number Record up to 5 custom words Enter 7 d Note d 0 4 each representing custom word 70 71 72 73 or 74 respectively Any existing word will be announced Press to start recorder Begin speaking immediately after the third beep Speak the desired word cl...

Page 55: ...IBM PC compatible computer and appropriate interconnecting cables Either a HAYES brand SMARTMODEM 1200 Level 1 2 or higher external or Level 1 1 or higher with 4 position DIP switch internal style a HAYES brand Optima 336 external a HAYES brand Optima 24 Plus FAX96 or an Ademco CIA Modem or via a capable GSM or IP communications device Compass Downloader for Windows at revision level supporting Ly...

Page 56: ...The keypad will become active after the download communication is terminated 3 The detailed operation of the download functions is covered in the installation instructions for the Compass Downloader for Windows Remote Programming Advisory Notes Keypad entries are ignored during the time interval stated above A copy of the program downloaded may be printed using the IBM PC compatible computer s int...

Page 57: ...e time The panic functions are identified by the system as follows Keys Displayed as Zone 1 95 99 3 96 Important For the silent panic functions to be of practical value the system must be connected to a central station Security Codes Installer Code The installer programs the 4 digit Installer Code initially as part of the programming procedure The factory default Installer Code is 4 1 1 2 but may ...

Page 58: ...imum of seven additional times or until it is acknowledged Pressing any key on the Lynx Plus Series keypad will terminate acknowledge both the follow me reminder and the local reminder announcements Notes 1 This feature is only supported if programmed in field 49 2 The follow me reminder will be terminated if any other event requires the system to dial out or if an audible alarm has occurred howev...

Page 59: ... the clock EE Invalid Entry Displayed when an invalid entry is made Phn Follow Me Phone Displayed when programming a Follow Me Phone Number EE Invalid Entry Data entry error invalid field number entered while programming Re enter a valid field number System Trouble Displays Display Meaning CC Modem Comm Appears when the system is communicating with the central station for change of function or sta...

Page 60: ...hat is in alarm FIRE A Fire Alarm or Fire Fault is present Accompanied by a display of the zone that is in alarm CO Displayed when a Carbon Monoxide Alarm or Fault is present No AC AC power is not present If displayed the system is operating on backup battery power Stay Perimeter Burglary zones such as protected windows and doors are armed Away All burglary zones interior and perimeter are armed S...

Page 61: ...The Central Station operator begins the session which last 5 minutes by entering one of the valid AAV commands shown in the table below The session may be extended 5 minutes without changing the operating mode by pressing the 7 key on the touch tone phone Selecting another operating mode also resets the session an additional 5 minutes During the last minute of the 5 minute session the Lynx Plus Se...

Page 62: ...t tests will be in progress 1 Arm the system and fault one or more zones After 15 seconds if optional dialer delay is selected silence alarm sounder s by entering the code and pressing OFF Check entry exit delay zones 2 Check the keypad initiated alarms that are in the system by pressing the Panic key pairs If the system has been programmed for audible emergency the keypad will emit a steady alarm...

Page 63: ...llowing chart defines the handshake kissoff frequencies that the panel supports and the different formats that can be sent for each FORMAT HANDSHAKE TRANSMITS DATA KISSOFF TRANSMIT TIME Low Speed 3 1 4 1 4 2 1400Hz 1900Hz 10PPS Standard report 1400Hz Under 15 seconds Sescoa Radionics 3 1 4 1 4 2 2300Hz 1900Hz 20PPS Standard report 2300Hz Under 10 seconds Express 4 2 1400 2300Hz DTMF 10 cps 1400Hz ...

Page 64: ...c contain zeroes in the ZZZ location CONTACT ID EVENT CODES Code Definition 110 Fire Alarm 121 Duress 122 Alarm 24 hour Silent 123 Alarm 24 hour Audible 131 Alarm Perimeter 132 Alarm Interior 134 Alarm Entry Exit 135 Alarm Day Night 146 Silent Burglary 150 Alarm 24 Hour Auxiliary 162 Alarm Carbon Monoxide Detector 301 AC Power 302 Low System Battery Battery Test Fail 344 RF Jam Detected 353 ECP Co...

Page 65: ...lace battery in the RF keypad 3c Replace the battery in the displayed transmitter 3d Ensure that battery is properly connected 4 Periodic beep s from keypad 4a System is in Test mode 4b A transmitter low battery has occurred and is displayed 4c A supervision fault has occurred 4d System low battery 4a Enter Code OFF to exit Test mode 4b Enter Code OFF and replace the battery 4c Check the transmitt...

Page 66: ...t not on 3a Open or faulted zone s 3a Check for faulted zones and make intact or use Bypass arming if desired 4 System doesn t respond to keystrokes on keypad 4a CC displayed 4b d1 displayed 4a System is in communication with downloader at central station 4b System has just been powered and is in its one minute initialization 4a Wait until download session is finished 4b Wait for initialization to...

Page 67: ...7 7 7 7 7 7 7 7 49 Split dual reporting 0 0 0 9 50 15 second dialer delay burglary 0 1 0 0 51 Periodic test report 0 3 0 0 52 First test report offset 2 2 2 2 53 Sescoa radionics select 0 0 0 0 54 Lack of usage notification 0 0 0 0 55 Reporting Channels 0 0 0 0 56 Enhanced Zone programming See 56 table See 56 table See 56 table See 56 table 58 RF jam detection 0 0 0 0 59 Exit error report code 1 0...

Page 68: ...ger characters 89 Event log 80 full report code 0 0 0 0 0 0 0 0 90 Event logging 3 15 3 3 91 Alarm audio verification remote phone control 2 2 2 2 92 Number of reports in armed period 0 0 0 0 93 Flexible call back 0 0 0 0 94 Download phone number 95 Ring detect count for downloading remote phone control 15 15 15 15 Default Master Code 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Default Duress Code By activati...

Page 69: ...imary secondary 7 7 7 7 7 7 7 7 49 Split dual reporting 0 0 0 9 50 Burglary abort window 2 2 2 2 51 Periodic test report 0 3 0 0 52 First test report offset 2 2 2 2 53 Sescoa radionics select 0 0 0 0 54 Lack of usage notification 0 0 0 0 55 Reporting channels 0 0 0 0 56 Enhanced zone programming See 56 table See 56 table See 56 table See 56 table 57 False alarm options 7 7 7 7 58 RF jam detection ...

Page 70: ...0 0 0 0 87 Auxiliary Function 1 button paging 0 1 0 1 88 Pager characters 89 Event log 80 full report code 0 0 0 0 0 0 0 0 90 Event logging 3 15 3 3 91 Alarm audio verification remote phone control 2 2 2 2 92 Swinger shutdown 1 1 1 1 93 Flexible call back 0 0 0 0 94 Download phone number 95 Ring detect count for downloading remote phone control 15 15 15 15 Default Master Code 1 2 3 4 1 2 3 4 1 2 3...

Page 71: ...04 GARAGE DOOR 5 04 1 0 3 RF 1 56 MOTION DETECTOR 6 09 1 0 3 RF 1 22 02 SMOKE DETECTOR 26 21 1 0 5 BR 3 27 22 1 0 5 BR 2 28 20 1 0 5 BR 4 29 23 0 0 5 BR 1 30 21 1 0 5 BR 3 31 22 1 0 5 BR 2 32 20 1 0 5 BR 4 33 23 0 0 5 BR 1 92 1 0 95 08 1 0 96 09 1 0 99 07 1 0 NOTE Zone 1 is a hardwire zone Zone 2 to 41 are RF zones Zone 92 is Duress Zones 95 96 and 99 are keypad panics 56 ZONE ASSIGNMENT ALARM REP...

Page 72: ...16 2 33 36 80 DEFAULT TABLE Applies to Default Table 4 devices 02 07 have no default values devices 10 15 have all default values set to 00 Start Stop Device Number Action Event Zone List Zone Type System Operation Restore of Zone List Zone type System operation 01 2 2 1 2 08 2 33 36 09 2 2 1 2 16 2 33 36 NOTE If using an X10 Powerhouse Security SH10A siren as device 08 you must change the device ...

Page 73: ...ver of this equipment is a label that contains the FCC registration number and Ringer Equivalence Number REN You must provide this information to the telephone company when requested This equipment uses the following USOC jack RJ31X This equipment may not be used on telephone company provided coin service Connection to party lines is subject to state tariffs This equipment is hearing aid compatibl...

Page 74: ...ered by those beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their detection ability Passive Infrared Detectors sense changes in temperature however as the ambient tempe...

Page 75: ...hout standard line security or encrypted line security or c 120 seconds for a system that does not transmit an alarm signal to a remote monitoring location SIA Quick Reference Guide 1 31 Single Alarm Sounding per Zone If 0 selected alarm sounding per zone will be the same as the number of reports in armed period set in field 92 1 if 1 report 2 if 2 reports 2 34 Exit Delay Options include 45 96 and...

Page 76: ... Line Seize Double Pole Ringer Equivalence 0 6B FCC Registration No 5GBUSA 25623 AL E Contacting Technical Support PLEASE before you call Technical Support be sure you READ THE INSTRUCTIONS Check all wiring connections Determine that the power supply and or backup battery are supplying proper voltages Verify your programming information where applicable Note the proper model number of this product...

Page 77: ...port code 67 69 Bypass restore report code 67 69 C Call waiting disable 24 Callback number 37 Cancel report code 67 69 Canceled alarm 31 Change the master code 57 Chime mode 21 Chime by zone 67 69 Closing report 23 Communication overview 63 Confirmation of arming ding 67 69 Connecting configuring communication modules 9 10 Contact ID event codes 64 Contact ID format 31 Contact ID reporting 64 76 C...

Page 78: ...g default tables 67 69 Q Quick arm enable 67 69 Quick exit 23 R Radionics 27 Radionics sescoa 76 Range 13 Real time clock display 67 69 Rec 60 Redundant reporting dynamic signaling delay 67 69 Remote phone control 58 Remote programming 55 Remote programming control 55 Replacing the rechargeable battery 12 Report code formats 63 Report codes 30 Report format 67 69 RF 39 RF supervised RF 13 RF house...

Page 79: ...scriptor 38 52 Voice prompt programming mode 16 Voltage input 76 W Wall mounting 6 WAVE2EX 76 Wireless buttons 13 Wireless transmitter 32 Wireless zones 13 Wiring connections 7 World wide web address 76 X X10 43 55 Z Zone entry to list 47 Zone list 17 67 69 72 Zone number 38 Zone programming 67 69 Zone response type 18 Zone type 38 ...

Page 80: ...TS THE TOTAL DELAY CONTROL UNIT PLUS SMOKE DETECTORS SHALL NOT EXCEED 60 SECONDS NO OTHER INITIATING DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION WARNING 5806 10 seconds 30 seconds 02 25 ZT16 1000 300 SOC V1 FCC ID CFS8DLLYNXPLUS LYNX PLUS SERIES COMPLIES WITH FCC RULES PART 68 FCC REGISTRATION No 5GBUSA 25623 AL E RINGER EQUIVALENCE 0 6B ...

Reviews: