background image

 

– 11 – 

About The Keypads 

(Cont’d)

 

 

FIXED-WORD DISPLAY KEYPAD 

 

AWAY:  

All burglary zones, interior and 
perimeter, are armed. 

 

STAY:  

Perimeter burglary zones, such as 
protected windows and doors, are 
armed. 

NIGHT-STAY:  

When specific interior zones are 
armed and all others bypassed, the 
NIGHT and STAY indicators are both 
on. 

 

INSTANT:  

Entry delay is turned off:  

 

 

Lit with STAY = Instant mode  
Lit with AWAY = Maximum mode

 

 

ALARM
FIRE

AWAY

BYPASS

STAY

CHECK    INSTANT    CANCELED

NIGHT NO AC

NOT READY

CHIME   BAT

PHONE TEST

6150disp

 

FIXED-WORD DISPLAY 

 

 

BYPASS:  

This appears when one or more burglary protection zones have been bypassed.

 

 

NOT READY: 

Appears when burglary portion of the system is not ready for arming (due to open 
protection zones). The system is ready to arm when this message disappears and 
the READY indicator light comes on. 

 NO 

AC: 

 

Appears when AC power has been cut off. System is operating on backup battery 
power. 

 AC: 

 

Appears when AC power is present. 

 CHIME: 

 

Appears when the chime feature is activated. 

 

BAT: 

 

Low battery condition in a wireless sensor (if zone number displayed) or low 
system battery (if no zone number displayed). 

 

ALARM: 

 

Appears when an intrusion has been detected and the system is armed (also 
appears during a fire alarm or audible emergency alarm). Accompanied by the 
protection zone in alarm. 

 

CHECK: 

 

Appears when a malfunction is discovered in the system at any time, or if an open 
is detected in a fire zone at any time, or a fault in a DAY/NIGHT burglary zone 
during a disarmed period. Accompanied by a display of zone number in trouble. 

 FIRE: 

Appears when a fire alarm is generated. Accompanied by a display of the zone in 
alarm. 

 

 

A FIRE display also appears when a fire alarm is manually activated, 
accompanied by a display of emergency key zone number programmed for fire. 

 

CANCELED: 

Appears when an alarm has been silenced by the Code + OFF sequence and will 
remain on until another Code + OFF sequence is keyed. 

www.PDF-Zoo.com

Summary of Contents for LXL-1000

Page 1: ... XL SERIES ADEMCO LYNX XL SERIES ADEMCO LYNX XL SERIES Security Systems Security Systems Security Systems Security Systems LXL LXL LXL LXL 1000 LXL 1000 LXL 1000 LXL 1000 LXL 1010 1010 1010 1010 User Guide User Guide User Guide User Guide www PDF Zoo com ...

Page 2: ...premises This would include any skylights that may be present and the upper windows in a multi level building In addition we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Central Monitoring Station in the event that the telephone lines are out of order alarm signals are normally sent over the phone lines EARLY WARNING FIRE DETECTION Early w...

Page 3: ...y Entry Delay On 18 NIGHT STAY Mode Arms Perimeter Only Plus Selected Zones 18 INSTANT Mode Arms Perimeter Only Entry Delay Off 18 AWAY Mode Arms Entire System Entry Delay On 18 MAXIMUM Mode Arms Entire System Entry Delay Off 18 Arming Commands 19 Single Button Arming 20 Single Button Step Arming 20 Disarming and Silencing Alarms 21 Bypassing Protection Zones 22 Using the BYPASS Key 22 Quick Bypas...

Page 4: ...nd Attributes 33 Scheduling 34 About Scheduling 34 Creating Schedules 34 Event Logging Procedures 36 About Event Logging 36 Viewing the Event Log 36 Table of Event Log Codes 37 Testing the System 38 About Testing the System 38 Trouble Conditions 39 Maintaining Your System 42 Fire Alarm System 43 Quick Guide to Basic System Functions 47 Summary of Audible Visual Notifications 48 Regulatory Statemen...

Page 5: ...t include fire protection check with your installer System Basics Burglary Protection Several modes of burglary protection Stay Night Stay Away Instant Maximum STAY arms perimeter zones only and entry delay is on INSTANT same as STAY except entry delay is off NIGHT STAY arms perimeter zones and selected interior zones entry delay on AWAY arms perimeter and all interior zones entry delay is on MAXI...

Page 6: ...system You can also use the step arming feature if programmed to arm the system This is a function key that allows you to arm the system in one of three modes by simply pressing the key repeatedly To disarm the system enter your user code then press the OFF key Alarms When an alarm occurs both the keypad and external sounders will sound and the keypad will display the zone s causing the alarm If y...

Page 7: ...me each day LED Indications The control utilizes three Security System Control Status LEDs that indicate control arming state and power status as follows READY LED Green Lit when the system is disarmed and ready to be armed no open zones If the system is disarmed and the green light is off the system is not ready one or more zones are open POWER LED Yellow Indicates system power status Lit Steady ...

Page 8: ...ARMED READY RECORD VOLUME PLAY STATUS FUNCTION VOICE SPEAKER CONTROL LEDS FUNCTION KEYS LCD DISPLAY MICROPHONE MESSAGE LED Message Center Functions To Press these keys Notes record a message FUNCTION 0 VOICE 1 OFF RECORD The red MESSAGE LED lights Message remains in memory until a new message is recorded end recording 1 OFF RECORD The red MESSAGE LED flashes indicating message waiting play a messa...

Page 9: ...ing the premises it indicates that an alarm has occurred during your absence and an intruder may still be on the premises LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location Your keypads are functionally the same but may have different types of displays depending on the type installed with your system Alpha Display 2 line alpha display keypads feature a 2 line 32 character alphanu...

Page 10: ... ARMED READY RECORD VOLUME PLAY STATUS FUNCTION VOICE 1 OFF 4 MAX 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6BYPASS 9CHIME ARMED READY 5828 00 001 V0 5828V FIXED WORD KEYPAD 5828 FIXED WORD KEYPAD 5839 004 V0 PANIC READY INSTANT CODE CHIME MAX TEST BYPASS OFF AWAY STAY 4 5 6 7 8 0 1 2 3 9 DISARMED READY TO ARM FIRST PRESS ANY KEY TO PLACE KEYPAD INTO ACTIVE STATE THEN PRESS KEY TO OBTAIN STATU...

Page 11: ...em is operating on backup battery power AC Appears when AC power is present CHIME Appears when the chime feature is activated BAT Low battery condition in a wireless sensor if zone number displayed or low system battery if no zone number displayed ALARM Appears when an intrusion has been detected and the system is armed also appears during a fire alarm or audible emergency alarm Accompanied by the...

Page 12: ...ber on the following pages for a description of usage When entering codes and commands sequential key depressions must be made within 4 5 seconds of one another If 4 5 seconds elapse without a key depression the entry will be aborted and must be repeated from its beginning Be sure to observe this precaution when performing any of the procedures in this manual If you make a mistake while entering a...

Page 13: ...tem status 4 3 STAY Arms perimeter portion of burglary system only Interior protection is not armed allowing movement within premises without causing an alarm PLAY On Voice keypads used in conjunction with the FUNCTION and VOICE keys to play the recorded message On Voice keypads used in conjunction with the FUNCTION and VOLUME keys to raise the message and voice system status volume 5 MIC On voice...

Page 14: ...ey a second time annunciates and displays system and or zone faults if they exist 16 KEYS 0 9 Used to enter your security code s and to perform their associated system functions after the security code has been entered 17 FUNCTION KEYS If your keypad has A B C D keys they may have been programmed for a variety of functions including panic emergency functions For details see the Function Keys secti...

Page 15: ...ff an alarm Exit delay begins immediately after arming your system in any arming mode and Alpha Display keypads display the message You May Exit Now When You may exit now disappears the system is fully armed If programmed a slow beeping will sound during the exit delay period until the last 10 seconds which then changes to fast beeping alerting you to the end of exit delay If you cannot leave with...

Page 16: ...F If you do not disarm the system before the entry delay ends and an entry exit door or interior zone is still open the alarm sound continues and an exit alarm message is sent to the Central Monitoring Station The message EXIT ALARM or EA is displayed on the keypad along with a zone number indicating the faulted zone To stop the alarm you must disarm the system by entering your 4 digit code follow...

Page 17: ...yed The keypad s READY indicator lights when all protection zones have been either closed or bypassed 3 Arm the system as desired Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display Zone no and NOT READY Voice Status Voice keypads if installed can announce system status and faulted zones up to 3 zone descriptors if the Voice Status feature is turned on To turn the Voice Status feature o...

Page 18: ...zones are armed and cause an alarm if anyone enters those areas e g waking in the middle of the night To avoid sounding an alarm you must disarm the system before any activity takes place in those interior zones INSTANT Mode Arms Perimeter Only Entry Delay Off Used when staying inside and do not expect anyone to use an entry exit door Arms same as STAY mode An alarm sounds immediately if any prote...

Page 19: ...d ARMED indicator lights Leave the premises through an entry exit door during the exit delay period to avoid causing an alarm The keypad beeps rapidly during the last 5 seconds of the exit delay to warn you that it is ending MAXIMUM security code 4 MAX same as AWAY described above Note that entry delay is turned off Quick Arming If Quick Arming was programmed by the installer the key can be presse...

Page 20: ...ned function key for 2 seconds no code is required Function keys are shown below 3 2 1 6 5 4 9 8 7 0 READY INSTANT OFF CODE AWAY TEST CHECK STAY BYPASS A B C D ADT3000 007 V0 Alpha Display DISARMED READY TO ARM Fixed Word Display Green LED lit 2 The keypad begins beeping and displays the armed message The red ARMED indicator also lights Alpha Display ARMED AWAY YOU MAY EXIT NOW Fixed Word Display ...

Page 21: ...tone to confirm that the system is disarmed and the RED LED indicator will go out If the system was in ALARM note the zone in alarm on the keypad display and correct the problem close door window etc After correcting the problem clear the keypad s Memory of Alarm display as described below Alpha Display DISARMED READY TO ARM Fixed Word Display READY Clear a Memory of Alarm Enter your 4 digit secur...

Page 22: ...will not allow fire zones to be bypassed Zones are automatically unbypassed when the system is disarmed 1 6 BYPASS zone numbers see below Security Code Enter the 2 digit zone number s for the zone s to be bypassed e g 06 10 13 etc Single digit zone numbers must be preceded by a zero e g 05 06 Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display NOT READY 2 When finished the keypad will m...

Page 23: ...ts all open zones will be displayed and automatically bypassed Make sure that only those zones that you wish to leave unprotected are bypassed and that there are no other zones unintentionally left open Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display NOT READY 2 Wait for all bypassed zones to be displayed then arm the system as desired Ask your installer if Quick Bypass is active fo...

Page 24: ...m Fixed Word Display CHIME To turn Chime Mode off 9 CHIME Security Code The CHIME message will disappear Alpha Display DISARMED READY TO ARM Fixed Word Display READY Using the Voice Chime Voice keypads have a feature that works in concert with the Chime Mode called Voice Chime Voice chime provides a voice status annunciation chime and display when any faulted entry exit or perimeter zone exists As...

Page 25: ... the box beneath that key Setting the Date and Time You can set the time and date by doing the following 1 6 3 Security Code Alpha Display DISARMED READY TO ARM 2 Press when the time date is displayed A cursor appears under the first digit of the hour To move cursor ahead press To go back press Enter the 2 digit hour setting Enter the 2 digit minute setting Press 1 for PM or 0 for AM Enter the las...

Page 26: ...tivate a Panic Function Press and hold down for at least 2 seconds whichever lettered key on the keypad has been programmed for the desired emergency function OR Press both keys of the assigned key pair at the same time Normal Alpha Display DISARMED READY TO ARM Fixed Word Display READY Typical Panic Alpha Display ALARM 96 ZONE 96 Fixed Word Display 96 and ALARM 1 OFF 4 MAX 7 INSTANT READY 2 AWAY ...

Page 27: ...e macros can be assigned See the chart at the back of this manual for the key s assigned for macros 1 6 6 Security Code Alpha Display DISARMED READY TO ARM 2 Enter the macro number 1 2 to be programmed at the Select Macro prompt Remember only one macro can be assigned to each key SELECT MACRO 1 2 0 3 If a macro has been previously defined the keystrokes are shown on the bottom line of the display ...

Page 28: ...ty system in the AWAY mode The procedures in the table that follows show you how you would program this macro Function Keystrokes Required Keypad Display 1 Bypass zones 02 03 Press BYPASS 6 key then 2 digit zone numbers 02 03 6 0 2 0 3 2 Insert terminator Press the D key for at least 2 seconds 6 0 2 0 3 F 3 Turn light on device 01 Press and 7 key for device ON and 01 key for selecting device 1 6 0...

Page 29: ...ally turned on or off using the commands described below See your installer for a list of devices that may be set up for your system A list of these devices is provided at the back of this manual for you to fill out To Activate Devices 7 2 digit device number Security Code Devices associated with that device number activate To Deactivate Devices 8 2 digit device number Security Code Devices associ...

Page 30: ...vent Code È È È È Optional 16 digits Æ Æ Æ Æ AAAAAAAAAAAAAAAA BBB CCCC Å Å Å Å 4 digit User or Zone No A B C Optional 16 digits for Account numbers PIN numbers or any other data programmed by the installer if required A 3 digit code that describes the event that has occurred in your system see for event codes table below A 4 digit User or Zone number depending on the type of event that has occurre...

Page 31: ... for beep then press the pager number 1 2 representing the pager intended to receive the message 2 The recipient on seeing the 999 9999 message will understand the prearranged meaning of this signal If no number is pressed the message is sent to pager 1 Alpha Display DISARMED READY TO ARM Fixed Word Display READY 999 9999 Pager Display Latch Key Paging You can program a schedule that causes a page...

Page 32: ...you usually need to do when adding users is assign a user number and a security code Authority Level Definitions Authority levels define the system functions a particular user can cannot perform Level Title Explanation N A System Master Reserved for user 02 Can perform all system functions and assign default 1234 codes can change its own code as follows Master code 8 02 new master code new master ...

Page 33: ...s see definitions on previous page users 04 49 0 0 standard user 2 guest 1 arm only 3 duress Access Group System Master Code 8 user no 2 group 1 8 Factory Defaults none You can assign users to a group then set an access schedule that defines the times this group of users can operate the system The system ignores these users outside the scheduled times RF User Number System Master Code 8 user no 4 ...

Page 34: ...duled event 01 turn a programmed output on or off ENTER EVENT see Using Device Commands section for a list of output device numbers used in your system 02 set a user access schedule for one or more users see Security Codes section for an explanation of access groups 03 send a latch key report to a pager if the system is not disarmed by a specified time message sent is 777 7777 04 automatically arm...

Page 35: ...Enter the desired repeat option 0 no repeat 1 repeat schedule weekly 2 repeat schedule biweekly every other week 3 repeat schedule every third week 4 repeat schedule every fourth week e g To make a schedule that happens everyday you would select all days with a repeat count of 1 To make a schedule that runs for one week then stops select everyday with a repeat count of 0 REPEAT OPTION 0 4 X 10 Sel...

Page 36: ...ing of any new event Viewing the Event Log 1 6 0 Master Code Alpha Displays DISARMED READY TO ARM 2 The system displays the most recent event as follows event number type of event identified by its corresponding code refer to the code table that follows zone or user number depending on type of event time and date of the event s occurrence 3 Pressing displays previous events back in time Pressing d...

Page 37: ...sion Mod Supervision 341 Trouble ECP Cover Tamper 344 RF Receiver Jam 351 Telco Line Fault 353 Long Range Radio Trouble 373 Fire Loop Trouble 374 Exit Error Alarm Code Definition 380 Global Trouble Trouble Day Night 381 RF Supervision Trouble 382 Supervision Auxiliary Wire Zone 383 RF Sensor Tamper 384 RF Sensor Low battery 401 Disarmed Armed AWAY Armed STAY 403 Schedule Arm Disarm AWAY 406 Cancel...

Page 38: ...en for three beeps from the keypad Identification zone number or zone description of each faulted protection point should appear on the display The display clears when the door or window is closed 5 Walk in front of any interior motion detectors if used and listen for three beeps The identification of the detector should appear on the display when it is activated The display clears when no motion ...

Page 39: ... enter the OFF sequence security code plus OFF key twice If the display persists CALL FOR SERVICE Note A display of CHECK 90 indicates that RF interference may be impeding the operation of wireless sensors in the system See Rcvr Jam on next page 2 If there are wireless sensors in your system the CHECK condition may also be caused by some change in the environment that prevents the wireless receive...

Page 40: ...pad If this condition persists for more than one day with AC present CALL FOR SERVICE LO BAT Indicates that there is a low battery zone descriptor condition in the wireless transmitter or BAT with number displayed 00 is RF keypad zone No Accompanied by a single beep about once every 40 seconds at the keypad Either replace the battery yourself or CALL FOR SERVICE If the battery is not replaced with...

Page 41: ...rupted and the system is inoperative CALL FOR SERVICE In The Event Of Telephone Operational Problems In the event of telephone operational problems disconnect the control from the phone line by removing the plug from the phone wall jack We recommend that your installer demonstrate this disconnection on installation of the system Do not attempt to disconnect the phone connection inside the control ...

Page 42: ...er and the portable wireless keypad and displays a low battery message A low battery in a portable wireless keypad is detected as soon as one of its keys is pressed and displayed as 00 Battery operated smoke detectors with a low battery also emit a single chirp sound approximately once every 20 30 seconds Alkaline batteries provide a minimum of 1 year of operation and in most units and application...

Page 43: ...YPAD FIXED WORD DISPLAY KEYPAD Silencing Fire Alarms and Clearing Memory of Alarm 1 You can silence the alarm at any time by pressing the OFF key To clear the display enter your code and press the OFF key again to clear Memory of Alarm 2 If the Keypad s FIRE display does not clear after the second OFF sequence smoke detectors may still be responding to smoke or heat producing objects in their vici...

Page 44: ...ify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone number s of the zone s in an alarm condition will be displayed at the keypad Using the Panic Key s Assigned for FIRE Emergency A key or key pair may have been assigned for manually initiating a FIRE alarm See the Panic Keys section for key assignments For convenience indicate...

Page 45: ...tion is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you instal...

Page 46: ...d 3 Sketch a floor plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check yo...

Page 47: ...red Determine cause Disarm System Enter code Press OFF key Also silences sounders Memory of alarm remains until cleared Clear Alarm Memory After disarming enter code again Press OFF key again Keypad beeps rapidly on entry if alarm has occurred while absent Alarm display will remain upon disarming until cleared Duress if active and connected to Central Station Arm or disarm normally but use your 4 ...

Page 48: ...TTER a Opened zone numbers will appear b BAT displayed with zone number of transmitter TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM AWAY is displayed Red ARMED indicator is lit THREE SHORT BEEPS Keypad only a ARM STAY NIGHT STAY INSTANT b ZONE OPENED WITH SYSTEM IN CHIME MODE a STAY or INSTANT is displayed Red ARMED indicator is lit b CHIME displayed zone number of open protection zone will be ...

Page 49: ...tions will appear b LO BAT displayed with description of transmitter TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM ARMED AWAY or MAXIMUM displayed Red ARMED indicator lit THREE SHORT BEEPS Keypad only a ARM STAY NIGHT STAY OR INSTANT b ZONE OPENED WHILE SYSTEM IS DISARMED a ARMED STAY or ARMED INSTANT displayed Red ARMED indicator lit b CHIME displayed descriptor of open protection zone will be ...

Page 50: ...B 003 du Canada TELEPHONE MODEM INTERFACE FCC Part 68 This equipment complies with Part 68 of the FCC rules On the front cover of this equipment is a label that contains the FCC registration number and Ringer Equivalence Number REN You must provide this information to the telephone company when requested This equipment uses the following USOC jack RJ31X This equipment may not be used on telephone ...

Page 51: ...ss yes no Automatic Paging yes no users Function Keys A B C D Comments Single Button Arming Step Arming Paging see Paging chart Time Date Display Macro Key 1 Macro Key 2 Emergency Key Personal Emergency Key Silent Alarm Emergency Key Audible Alarm Emergency Key Fire Device Activation Device Emergency Keys A 1 B C 3 www PDF Zoo com ...

Page 52: ...evel 1 level Access Group 2 group RF Zone Number 4 zone no Pager on off 5 0 1 01 installer installer 1 02 system master master 1 03 4 1 04 0 1 05 0 1 06 0 1 07 0 1 08 0 1 09 0 1 10 0 1 11 0 1 12 0 1 13 0 1 14 0 1 15 0 1 16 0 1 17 0 1 18 0 1 19 0 1 20 0 1 21 0 1 22 0 1 23 0 1 24 0 1 25 0 1 26 0 1 27 0 1 28 0 1 29 0 1 30 0 1 31 0 1 32 0 1 Authority Levels 0 standard user 1 arm only 2 guest 3 duress ...

Page 53: ...01 events for 02 events Time Time 1 4 yes no see device list below enter 1 8 Day Day 01 02 03 04 Events 00 clear event 03 latch key report 06 auto disarm 01 device on off 04 forced STAY arm 07 display reminder 02 user access 05 forced AWAY arm Repeat Options 0 none 1 repeat weekly 2 repeat every other week 3 repeat every third week 4 repeat every fourth week List of Output Devices Device Descripti...

Page 54: ...t injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place beh...

Page 55: ...surance Company Policy No LXL 1000 1010 Other _______________________________ Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fire Local Sounding Device Police Dept Fire Dept Monitoring Station Name Address Phone C POWERED BY AC With Rechargeable Power Supply D TESTING Quarterly Monthly Weekly Other continued on other side www PDF ...

Page 56: ...ement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1 st Floor Windows All windows Interior locations All Accessible Openings Including Skylights Air Conditioners and Vents G ADDITIONAL PERTINENT INFORMATION Signature Date www PDF Zoo com ...

Page 57: ...essage 19 Armed Away 20 Armed Stay 20 Attributes 33 Audible Emergency Alarm 11 Authority Levels 6 32 Automatic Paging 30 Away 3 5 7 11 15 18 19 20 27 28 34 37 47 48 49 53 B Babysitter Code 32 Backlighting 9 Back Up Battery 11 41 Battery Life 42 Battery Replacement 42 Battery Operated Smoke Detector 42 Burglary Protection 5 Busy Standby 41 Bypass 5 11 22 Bypass Zone s 47 Bypass Message 22 23 Bypass...

Page 58: ...Delay Period 19 Exit Delay Restart 15 Exit Error Alarm 37 External Sounder 38 External Sounders 6 F False Alarms 16 18 FC 40 Fire 5 11 Fire Alarm 11 26 43 Fire Detection Equipment 45 Fire Display 11 43 Fire Emergency 44 Fire Message 43 Fire Protection 5 Fire Zone 11 Fixed Word Display 9 Fixed Word Display 11 Fixed Word Display Keypads 13 48 Flip Down Front Door 12 Function Key Arming 19 Function K...

Page 59: ... No AC 11 41 Not Ready 11 17 O Open Circuit 41 Open Zone 17 Owner s Premium Credit Request 55 P Pager Display Format 30 Pager Displays 30 Pagers 30 Paging Feature 4 7 30 31 Panic Alarms 47 Panic Keys 26 44 Path of Escape 46 Personal Emergency 26 Pets 18 PIN Number 30 Plan of Escape 46 Play a Message 8 Portable Wireless Keypad 42 Pre Designated Words 9 13 Primary Entrance 15 Protection Zone ID 13 Q...

Page 60: ...Stay Mode 20 Step Arming 20 Subscriber Account Number 30 System Lo Bat 40 T Telco Line 37 Telephone Operational Problems 41 Temporal Pulse Sounding 43 Terminator 27 Test Mode 47 Testing The System 38 Total Power Failure 41 Trouble Conditions 39 Trouble Displays 40 41 Typical Check Displays 39 U User Codes 33 V Voice Chime 9 24 Voice Chime 24 Voice Keypads 9 Voice Message Center 8 W Warning Tones 4...

Page 61: ...ABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above...

Page 62: ... 62 NOTES www PDF Zoo com ...

Page 63: ... 63 NOTES www PDF Zoo com ...

Page 64: ... K9350V1DŠ K9350V1 3 05 Rev A www PDF Zoo com ...

Reviews: