Limitless™ WPMM Series
Issue 2
50051864
Honeywell Sensing and Control
18
6.4
Troubleshooting Mode
Troubleshooting mode can be initiated to determine functional issues with the WPMM and/or Limitless™ switch.
Ensure proper power is applied to the WPMM (green LED
illuminated) before proceeding with this procedure.
Step Action
1
Completely read this procedure before starting in order to understand the timing of events that need to be
performed. Refer to Figure 10.
2
Press the Function button
on the WPMM for more than one second and less than four seconds at which
time the green
LED will be flashing which indicates to release the function button
immediately as it has
entered the Troubleshooting mode.
3
Press the Function button
on the WPMM for less than one second at which time the green
LED will
indicate the Limitless™ switch sequence # and if there are any functional issues with this Limitless™ switch.
The first Limitless™ switch paired (Sequence #1 switch) will be the first to be indicated as the buzzer will
beep once and the green
LED will blink once and then will pause for one second.
The following may be displayed dependent on the first Limitless™ switch status:
a)
Green
LED illuminated which indicates normal operation with the Limitless™ switch not actuated.
b)
Red
output LED will illuminate for four seconds if the Limitless™ switch is actuated and the
buzzer will buzz for up to four seconds
c)
Amber
LED flashes at four blinks per second for four seconds indicating Limitless™ switch low
battery (Red
output LED may also be displayed if actuated)
d)
Amber
LED remains illuminated for four seconds indicating insufficient RF link
e)
Red
LED flashes and buzzer beeps rapidly the sequence # of the Limitless™ switch that has
been purged. (FYI - A purged Limitless™ switch was originally in the system but has since been
removed. See Section 6.5 “Purge Mode” for details)
4
Step #3 results can then be reviewed for the rest of the Limitless™ switches (up to 15 more) that have been
paired to the WPMM. After the green
LED starts flashing again, the functional button
can be pushed.
This will then display the second Limitless™ switch (Sequence #2 switch) per step #3.
5
When the last Limitless™ switch paired to the WPMM, the green
LED will be flashing and upon actuation
of the functional button
. All LEDs will not illuminate for one second and the WPMM will return to normal
operation with the green
LED illuminated.
ATTENTION
The WPMM will go back to normal operation after 35 seconds if pairing does not occur.
Figure 10. Limitless™ WPMM LED Display
NOTE:
Use a blunt object, such as a paper clip or tooth pick to actuate the function switch
.