- 21
-
③
Sensitivity
:
User can decide sensitivity of motion detection.
SENSITIVITY LOW
→
MID
→
HIGH
④
Output of motion detection
: Motion detection has two output method. One is marking
on screen
“
“
icon, and the other is MD signal.
OUTPUT MARK
→
ALRAM
⑤
Mirror Mode
: Mode set makes Mirrored image.
MIRROR OFF
→
H MIRROR
→
V MIRROR
→
FLIP
⑥
STILL
: It pause current image. ON is to stop, OFF is to return to normal
state.
STILL OFF
→
ON
<< MD MODE >>
MODE
AREA SEL
SENSITIVITY
OUTPUT
RETURN
OFF
LOW
MARK
<Fig5-23. MD MODE >
5.3 SPECIAL SETUP
①
Sharpness
: Use to change the contour of Scene.
SHARPNESS 0 ~ 15
②
Gamma
:
Gamma is controllable
GAMMA 0.36
→
0.38
→
…
→
USER
<< SPECIAL SETUP >>
SHARPNESS
GAMMA
BAUDRATE
PROTOCOL
LANGUAGE
MONO
8
3
9600
DEFAULT
ENG
RETURN
OFF
<Fig5-24. SPECIAL SETUP >
③
BAUD RATE
: Use to communicate through RS232C, RS485, RS232TTL .
BAUDRATE 2400
→
4800
→
…
.
→
57600
☞
caution
1.
If the Baud Rate does not match between Camera and external
system, it may occur the communication failure. Please make
sure a proper Baud Rate.
④
PROTOCOL Setting
: Setting the PROTOCOL with communication device.
PROTOCOL DEFAULT
→
VCL
→
KD6
→
PELCO
⑤
OSD language
LANGUAGE ENG
→ 한국어 →日本語 →
簡體中文 → 繁體中文
⑥
Color Mode
: Use for changing color and monochrome ( black & white )mode .
OFF is Color mode, ON is black&white mode.
MONO OFF
→
ON
5.5 FACTORY DEFAULT
: At main menu, select icon, and press MENU button.
If you press
“
Factory default
”
, all data will be returned
factory default values