5 - 13
If this bar code is read:
the data is output as:
1234AB
<CR>
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the
current cursor position. The format is aborted if the character is
numeric.
ED Example: Only output the data if the bar code begins with a
letter
If you want only data from bar codes that begin with a letter, you can
use ED to check for the letter.
Command string:
EDF10D
ED is the “Check for a non-numeric character” command
F1 is the “Send all characters” command
0D is the hex value for a CR
If this bar code is read,
the next data format, if
there is one, will be used on this data. If there is no other format, the
format fails and the raw data is output as
1234AB
.
If this bar code is read:
the data is output as:
AB1234
<CR>
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting
from the current cursor position. Syntax = EFnnnn where nnnn stands
for the delay in 5ms increments, up to 9999. This command can only
be used with keyboard emulation.
Summary of Contents for Hyperion 1300G
Page 1: ... Hyperion 1300g General Purpose Handheld Linear Scanner User s Guide ...
Page 10: ...viii ...
Page 53: ...3 9 Left of Centering Window Right of Centering Window Centering Off Centering On ...
Page 60: ...3 16 ...
Page 70: ...4 10 ...
Page 86: ...5 16 ...
Page 133: ...6 47 Label Code The standard Label Code is used in library situations Default Off On Off ...
Page 134: ...6 48 ...
Page 138: ...7 4 ...
Page 142: ...8 4 ...
Page 168: ...10 4 ...
Page 172: ...11 4 ...
Page 189: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Page 191: ......