SYSTEM DESCRIPTION AND INSTALLATION MANUAL
HS--600 High Speed Data System
23--20--31
30 May 2002
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 5--1
SECTION 5
ADJUSTMENT/TEST
1. Overview
A. General
(1) This section provides instructions for adjusting/testing the HS--600 HSD system.
2. Details
A. General
(1) Access to the maintenance functions is obtained by connecting a personal computer
(PC) to the RS--232 maintenance port connector. The maintenance port connector is
a 9--pin sub--D connector that is connected to the HSU mounting tray connector.
(2) To operate with a PC, the initial settings of the maintenance port must be as follows:
•
Speed, normally 115,200 bps
•
8 data bits
•
No parity
•
1 stop bit
•
Turn caps lock ON.
B. Software
(1) The software can be any communications package that can send and receive ASCII
at 115,200 baud rate, 8 bits with no parity bit, and 1 stop bit. Among the programs
that have been used are ProComm and HyperTerminal from Windows.
C. System Initialization
(1) Apply power to the SATCOM and HS--600 systems.
(2) Connect a cable from the PC to the front of the SDU as given in Table 5-1. The cable
connector that attaches to the front of the SDU is a 53--pin male connector. The cable
connector that attaches to the PC is a 9--pin female sub--D connector. Refer to
Figure 5-1.
Table 5-1. SDU to PC Wire List
From SDU Front Connector Pin
To PC Connector Pin
42
3
43
2
49
5
Summary of Contents for HS-600
Page 15: ...CONTENTS ...
Page 22: ...INTRODUCTION ...
Page 27: ...SYSTEMS DESCRIPTION AND OPERATION ...
Page 42: ...MECHANICAL INSTALLATION ...
Page 52: ...ELECTRICAL INSTALLATION ...
Page 64: ...INSTALLATION CHECK ...
Page 69: ...ADJUSTMENT TEST ...
Page 78: ...FAULT ISOLATION ...
Page 81: ...MAINTENANCE PRACTICES ...
Page 86: ...APPENDIX A ...
Page 97: ...APPENDIX B ...