HM700A1000
33-00118—01
16
Component
Function
Condensate Return
Provides a connection to return condensate to humidifier.
Control Terminal Strip
Terminal strip for connecting external controls to humidifier and interfacing with other equipment.
Cylinder Plug
Power connectors to electrodes in cylinder.
Cylinder
Holds electrodes in water. Current between electrodes generates heat used to generate steam.
Drain Canal
Combines cylinder drain water and fill cup overflow into a single drain outlet.
Drain Valve
Drains water from humidifier.
Control Board
Controls all functions of the humidifier operation and provides input and output connections to
humidifier components.
Fill Cup
Provides an air gap for backflow prevention.
Fill Valve
Controls flow of water into humidifier.
High Voltage Terminal
Block
Primary power connection from remote disconnect to humidifier.
High Water sensor Plug Used to detect max water level in cylinder.
On/Off/Drain Switch
Turns power on/off to humidifier controller and drains the cylinder for servicing. Note: Turn off
humidifier disconnect to shut off primary power to the humidifier.
Power Relay
Turns on/off power to cylinder electrodes based on a signal from the humidifier’s controller (mounted
on control board).
Steam Outlet
Connect to steam line with steam hose.
Transformer
Steps primary voltage down to 24 VAC for the controller and internal components such as the fill valve
and drain valve.