50461/GTEX MMC/1111
UTImeter Gtex MMC
49
12. Specifications
General Specifications
Accuracy of ullage-interface detection
±2 mm (± 0.08” approx.)
Ullage, interface indication
Audible or visible
Tape length
15 m/50 ft, 30 m/100 ft, 35 m/115 ft
Tape
graduation Metric/English
Tape
resolution
1
mm
/
1/16”
Tape accuracy
±3.2 mm/30 m (±1/8”/100 ft approx.)
Diameter of probe (without load)
23 mm (29/32” approx.)
Minimum detectable tank bottom liquid level
4 mm (5/32” approx.)
Maximum tank pressure
0,3 bar (4,4 psi)
Accuracy
±0.1°C (0°C to 70°C); ±0.2°F (32°F to 158°F)
meets API MPMS Chap 7 2001, table 3 requirements
meets ISO 4268 , IP PMM Part IV
Ambient temperature range
-20°C to 50 °C (-4°F to 122°F)
Temperature sensor measurement range
-40°C to 90°C (-40°F to to 194°F)
Temperature measurement resolution
0.01° or 0.1°, selectable
Temperature
reading
°C
or
°F,
selectable
LCD
Display
8
characters
Mechanical coupling
Q2 (2”) or Q1 (1”)
Hazardous environments approvals
IECEx
Zone 0 Ex ia IIB T4 20°C < Ta < +50°C
ATEX
II 1 G EEx ia IIB T4 / Tamb 50°C
Factory Mutual (FM Approvals)
CL I, DIV 1, GP C&D, T4 Tamb 50°C and
CL I, ZN 0, AEx ia IIB T4 Tamb 50°C
Multifunctions-Sensor
Ullage detection ultrasonic
Interface
detection
conductivity
Temperature
Platinium
RTD
Pt
1000
Innage / Reference height
additional load (option)
Tape
cleaning
device
UP / DOWN tape cleaner
Tape protection tube
on all units equipped with TS storage tubes
Maintenance
modular design / easy exchange of parts
Specifications subject to change without notice.