3.3 WIRING – UNSHIELDED TWISTED PAIR (UTP) OPTION, CONTINUED
SEE NOTES 1 & 2
SEE NOTES 1 & 2
ALIGNMENT TAB
W3
SW1
W4
TB3
W2
W1
TB1
ALIGNMENT TAB
TB2
SEE NOTE 2
BNC CONNECTOR
DATA OVER COAX (UTC) OPTION
VIDEO & DATA
SEE NOTE 2
CABLE CLAMP
0-90
90-180
180-270
270-365
365-455
0-300
300-600
600-900
900-1200
1200-1500
Off
Off
On
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
On
Off
On
Off
Off
Off
DIP Switch
Control & Video Over CAT5
SW1*
CAT5 Cable
Switch Position
Feet
Meters
1
2
3
4
* Use lowest switch setting possible.
Ex: If cable run is 900 feet, use 600-900 switch setting.
Make sure only one switch is set to ON.
REMOVABLE TOP PLATE
SPECIFICATIONS
WEIGHT : 5.5 lbs. (2.5 kg) WITH CAMERA
POWER REQUIREMENTS AT DOME: 24VAC, 50/60 Hz, 1.1A
NOTES:
1.
IF LARGER OR SMALLER WIRE IS REQUIRED, AN APPROPRIATE AWG MUST BE SPLICED
ONTO FIELD WIRE BEFORE INSERTING INTO TERMINAL STRIP.
2.
3. ALL DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS.
4. POWER SOURCE MUST BE 24VAC 10% AT POWER SUPPLY.
TERMINAL STRIPS TB1 & TB3 ACCEPT 18-22 AWG WIRE
TERMINAL STRIP TB2 ACCEPTS 12-18 AWG WIRE.
IF VIDEO IS ON UTP CABLE, BNC CONNECTOR IS NOT USED.
±
5. DATA CABLE SHIELD NOT CONNECTED AT DOME.
TB1-1
TB1-2
TB1-3
TB1-4
TB1-5
TB1-6
TB1-7
TB1-8
Alarm 1
Ground
Alarm 2
Gnd
RX-
RX+
TX+
TX-
TB3-1
TB3-2
Video +
Video -
TB2-1
TB2-2
TB2-3
24VAC
GND
24VAC
TERMINAL STRIP TB1
TERMINAL STRIP TB2
TERMINAL STRIP TB3
TWISTED PAIR
Jumper W1
Jumper W2
Jumpers W3 & W4
Terminated
Position 1 & 2 Last Dome on Data Loop
Unterminated
Position 2 & 3 All Intermediate Domes on Data Lo op
Positions 2 & 3 All Domes
UTP
Positions 1 & 2
Not Used
Positions 2 & 3
To use the board as standard (video over coax &2-wireR 485):
Positions 1 & 2
Positions 2 & 3
S
Jumper W3
Jumper W4
AWG
22
20
18
16
14
12
MAX. DISTANCE TO DOME
65 FEET (19 METERS)
100 FEET (30 METERS)
160 FEET (48 METERS)
260 FEET (79 METERS)
420 FEET (128 METERS)
650 FEET (198 METERS)
24 VAC POWER @1.1A
Figure 17: Unshielded Twisted Pair (UTP) Option – HD6 Rugged Dome
Rev. 1.02
38
900.0696
1-Aug-06
Summary of Contents for HD6 Series
Page 1: ...HD6 Series Housings Installation Manual 900 0696 August 2006 Rev 1 02 ...
Page 4: ...Rev 1 02 iv 900 0696 1 Aug 06 ...
Page 8: ...Rev 1 02 viii 900 0696 1 Aug 06 Notes ...
Page 12: ...Rev 1 02 2 900 0696 1 Aug 06 Notes ...
Page 28: ...Rev 1 02 18 900 0696 1 Aug 06 Notes ...
Page 51: ...Rev 1 02 41 900 0696 1 Aug 06 Notes ...
Page 52: ...Rev 1 02 42 900 0696 1 Aug 06 Notes ...
Page 53: ...Rev 1 02 43 900 0696 1 Aug 06 Notes ...
Page 54: ...Rev 1 02 44 900 0696 1 Aug 06 Notes ...