background image

H46C,E HUMIDITY CONTROLLERS

H46C

T87F/Q 539A INTERNALSCHEMATIC

M7914

Fig. 6. Typical series wiring  hookup of H46C with T87F/Q539A combination for dehumidification

and  mildew control.

SETTINGS AND ADJUSTMENT

The  H46  makes contact on a relative  humidity rise to the 

set point to start the dehumidifier. On a decrease  in 

relative  humidity to the set point (minus the  differential), 

the switch breaks contact to stop the  dehumidifier. Turn 
the knob clockwise to the setting stop to place the  H46 in 
the ON position. Turn the  knob counterclockwise to the 

stop to place the H46 in the Off position.

CHECKOUT

After all  mounting and wiring is completed, turn on the 
power supply. Place the system into operation by turning 
the setting knob toward the  low end of the scale  until the 

dehumidifier motor starts. Turn the  setting knob slowly 

toward the high end of the scale  until the dehumidifier 

motor stops.

Honeywell

Automation and Control Solutions

Honeywell International Inc. 

Honeywell Limited-Honeywell Limitée 

1985 Douglas Drive North 

35 Dynamic Drive

Golden Valley, M N  55422 

Scarborough,  Ontario
M1V 4Z9

69-1000B-1 

G.H.  Rev. 7-03

®

  Printed in U.S .A.  on  recycled 

paper c ontaining at  least  10% 
po st-consum er paper fibers.

www.honeywell.com/yourhome

Summary of Contents for H46E

Page 1: ...6C 1 Remove the setting knob 2 Pull the cover forward from the device to remove 3 Install a 2 in x 3 in 51 mm x 76 mm vertical switch box at the selected location 4 Using the two screws provided fasten the adapter plate to the switch box as shown See Fig 1 5 Pull the wires from the switch box through the opening in the adapter plate and connect to the H46 leadwires with the solderless connectors p...

Page 2: ...at can be wired in parallel or in series Wiring in parallel allows the dehumidistat to indepen dently control the humidity level but could cause overcooling of the home During unoccupied times the homeowner should set the thermostat to a relatively high setting and control moisture using the dehumidistat Wiring in series prevents overcooling but the air conditioner runs only when both the thermost...

Page 3: ...IDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED HEATING DAMPER MOTOR IF USED CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION COOLING CONTACTOR COIL FAN RELAY COIL A M7913 Fig 5 Typical parallel wiring hookup for H46C with T87F Q539A combination for dehumidification and mildew control 3 69 1000B 1 ...

Page 4: ...e knob counterclockwise to the stop to place the H46 in the Off position CHECKOUT After all mounting and wiring is completed turn on the power supply Place the system into operation by turning the setting knob toward the low end of the scale until the dehumidifier motor starts Turn the setting knob slowly toward the high end of the scale until the dehumidifier motor stops Honeywell Automation and ...

Page 5: ... sortie d air de l appareil de régulation Montage du H46C 1 Enlever le bouton de réglage 2 Tirer le couvercle vers l avant pour l enlever 3 Installer une boîte de commutation verticale de 51 x 76 mm 2 x 3 po à l endroit choisi 4 À l aide des deux vis fournies fixer la plaque d adaptation à la boîte de commutation Voir Fig 1 5 Passer les fils de la boîte de commutation dans l ouverture de la plaque...

Page 6: ...arallèle permet de faire fonctionner le déshumidistat de façon autonome pour qu il règle le taux d humidité sans provoquer le refroidissement exagéré de la maison Pendant les périodes d inoccupation le propriétaire devrait régler le thermostat à un réglage relativement élevé et maîtriser l humidité en se servant du déshumidistat Le raccordement en série empêche le refroidissement exagéré mais le s...

Page 7: ...C HYGROSTATS H46C E H46C SCHÉMA INTERNE DE Q539A T87F Fig 5 Schéma de câblage parallèle type du H46C et du T87F Q539A pour assurer la déshumidification et empêcher le développement de moisissure 3 1000B 1 ...

Page 8: ...ntihoraire jusqu au point d arrêt pour mettre le H46 à la position Off VERIFICATION Une fois le montage et le raccordement terminés mettre l hygrostat sous tension Tourner lentement le bouton de réglage vers l extrémité inférieure de l échelle jusqu à ce que le moteur du déshumidificateur se mette en marche Tourner lentement le bouton de réglage vers l extrémité supérieure de l échelle jusqu à ce ...

Reviews: