Section 3: Programming the Communicator
3-11
PROMPTS
ZONE
TRIG.
4204/
2-4204
OPTIONS
DESCRIPTION
9
Device Mode
(ECP)_
X
X
•
ECP
•
Zone Trig.
•
4204 Emu
•
Two 4204s
Press the [space] key to scroll through the modes of
operation.
Press [ENTER] to select the mode of operation.
IMPORTANT, if ECP device mode is desired, use
Table 3-2
for programming.
Important Information Regarding Multi-Mode Options
NOTE: In order for the Multi Mode, Remote Access, and Keypad Address programming fields to appear an account
must be created in the AlarmNet Direct website and “Remote Access” must be enabled for the comm device.
In Zone Trigger mode, the options for Multi-Mode are "Enabled" or "Disabled." If enabled, whenever a zone on the
communication device is triggered, a corresponding email message is sent INSTEAD of normal central station
reports. Cover tamper will send email event 8. All communication device system events (such as power loss, low
battery, Telco, etc.) are still sent to AlarmNet.
Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to
events triggering the hardwired zones.
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central
Station reporting of critical events (alarms, troubles, etc.).
UL
Multi-Mode has not been evaluated by UL.
10
Multi Mode
(Disabled)_
X
•
Enabled
•
Disabled
Enable if you want all events sent by email to the
user. Disable for normal alarm processing.
Important Information Regarding Primary Account (Questions 11-13)
Account information is provided by the central station administrator.
11
Primary City ID
(??)_
X
X
[01-99]
Enter the 2-digit primary city ID, 01-99 (decimal).
12
Primary CS ID
(???)
X
X
[01-FE]
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
13
Primary Sub ID
(????)
X
X
[0001-9999]
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
14
Device Address
(12)_
X
[01-15]
The GSMV4G communicates with the control panel
as a 4204 relay module. Enter the appropriate
address. For VISTA-10P and FA130CP Series
control panels, this must be address 12. For other
control panels, see their Installation and Setup
Guide.
NOTES:
1. The 4204 protocol limits address range to 01-15.
If using 2-4204 mode, the communicator assigns
the second 4204 to the next higher device address
(e.g., if entering address 12 for the first 4204, then
address 13 is automatically assigned to the second
4204 module). Program the control panel
accordingly.
2. The device address(es) must be unique from the
"Keypad Address" entered in Prompt 17 and any
other address used on the control panel.
UL
/
ULC
Remote access has not been evaluated by UL or ULC.
15
Remote Access
Y/N
(N)_
X
[Y], [N]
Press [Y] to allow the end user to access their
system via a website. Availability of this service is
controlled by the dealer via the web-based
programming tool on the AlarmNet Direct website.
Summary of Contents for GSMV4G
Page 2: ......
Page 40: ...GSMV4G GSMVCN4G Installation and Setup Guide 4 4 ...
Page 46: ...GSMV4G GSMVCN4G Installation and Setup Guide 5 6 ...
Page 47: ...A 1 Appendices Appendix A Summary of LED Operation ...
Page 48: ...GSMV4G GSMVCN4G Installation and Setup Guide A 2 ...
Page 50: ...GSMV4G GSMVCN4G Installation and Setup Guide B 2 ...
Page 52: ...GSMV4G GSMVCN4G Installation and Setup Guide C 2 ...
Page 53: ...NOTES ...
Page 54: ...NOTES ...
Page 55: ...NOTES ...
Page 56: ...NOTES ...
Page 57: ...NOTES ...
Page 58: ...NOTES ...
Page 59: ...NOTES ...
Page 60: ...NOTES ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...