www.metrologic.com
10
C
ONFIGURATION
P
ROCEDURES
CodeXML Protocol Compatibility
The CodeXML protocol
does not
support page/disconnect button functions, or
scanner firmware upgrades through the access point device and Metroset
2
.
When a scanner is using the CodeXML protocol, configuration data is stored in
the scanner. The stored data is not transmitted to the access point device.
Special configuration steps are required for the customization of system formats
and protocols. Instructions on how to configure a scanner in the CodeXML
protocol mode via the access point device are outlined on page 11.
CodeXML Firmware Requirements
Scanner Model
Firmware Version
Focus BT
15701 or higher
To configure a scanner to use the CodeXML protocol:
1. Scan
the
Disable Metrologic Protocol
bar code.
Disable Metro Protocol
³
1
2
5
6
0
4
2. Scan
the
Recall Defaults
bar code.
Recall Defaults
³
9
9
9
9
9
8
3. Scan
the
Enable CodeXML Protocol
bar code.
Enable CodeXML Protocol
³
1
2
5
6
1
7
4. Scan the address bar code located on the top of the access point device
(
see Figure 11, on page 8)
to establish a communication link between the
scanner and access point.
5. The scanner will beep to indicate a connection has been established.