107031-33-EN FR26 GLO 1101 Printed in France
9
2.4.5
Response Time
The response time of FF-SYA Series light curtains is the maximum time it takes the light curtain to generate a stop signal after
the sensing field has been interrupted. See the table below for response times for individual light curtains.
Model number
Response Time (FF-SYA14, FF-SYA30, FF-SYA60 Light Curtains)
FF-SYA14
FF-SYA30
FF-SYA60
032
14 ms
13,5 ms
13,5 ms
048
15 ms
14 ms
14 ms
064
15,5 ms
14 ms
14 ms
080
17,5 ms
14,5 ms
14,5 ms
096
19,5 ms
15 ms
15 ms
112
20,5 ms
15 ms
15 ms
128
22,5 ms
15,5 ms
15,5 ms
144
20 ms
16 ms
16 ms
160
21 ms
17,5 ms
17,5 ms
176
22,5 ms
17,5 ms
17,5 ms
NA : Not Available
Model
Response Time (FF-SYA234 Multibeam Systems for Access Detection)
FF-SYA02500
11,5 ms
FF-SYA03400
11,5 ms
FF-SYA04200
11,5 ms
Response time
Response times shown in the above table DO NOT include the response time of the optional FF-SRS59392 Interface Control
Module (when used).