Honeywell F35F Product Data Download Page 7

F35F Expandapac™ MEDIA AIR CLEANER

68-0178—2

7

Fig. 13. Typical use of duct offset to

make room for media air cleaner.

INSTALLATION AND CHECKOUT

When Installing this Product…

1. Read these instructions carefully. Failure to follow them

could damage the media air cleaner or cause a
hazardous condition.

2. Check the ratings given in the instructions and on the

media air cleaner to make sure the product is suitable
for your application.

3. Installer must be a trained, experienced service

technician.

Remove Furnace Filter and
Clean Blower Compartment

Before starting the installation, remove and discard the existing
furnace filter (if used). Thoroughly clean the blower
compartment. If possible, power vacuum the ductwork to
remove accumulated dust in an occupied home or remove
construction dirt in a new home. The media air filter cannot
remove dirt that has settled in the blower compartment and
distribution ducts.

Install the Cabinet

The following procedure describes a typical side installation
on an existing highboy furnace. Alternate procedures are
noted as appropriate. Other changes in installation
procedures may be necessary to complete your installation.

Review the Installation Plan

Temporarily place the cabinet on the floor, oriented as it will
be when installed. Measure to make sure the plan allows
adequate clearance (at least 26 in. [660 mm]) for easy
removal and replacement of the filter.

M948A

LESS
THAN
7 in.
(178 mm)

OFFSET

AT LEAST
7 in.
(178 mm)

1

1   REQUIRED TURNING VANES HELP DISTRIBUTE AIRFLOW EVENLY.

Make sure that shop-fabricated sheet metal components,
such as turning vanes, are available.

Fasten the Cabinet to the Furnace

Align the cabinet with the return air opening. Place blocks under
the cabinet, as necessary, to make sure the unit is seated
securely. Create an opening in the furnace to match the cabinet
opening. Attach the cabinet securely to the furnace. Attach the
unit directly or fit a starting collar in the furnace opening. Either
drill holes and fasten with sheet metal screws or rivets, or use
slip joints. If you are drilling holes, use a locking pliers to help
hold the unit in place during drilling.

Install Turning Vanes

Install turning vanes to help distribute air equally over the full
surface of the upstream side of the media. Install the vanes
whenever an abrupt 90 degree elbow is installed directly
against the media air cleaner cabinet.

Fasten Cabinet to Ductwork

Fasten the side of the cabinet to the ductwork using sheet
metal screws, rivets, or slip joints, as appropriate.

Connect Ductwork

Connect the vertical duct section to the elbow. If the vertical
drop of the duct is less than 7 in. (178 mm) from the side of
the furnace, shorten the horizontal trunk or attach an offset
fitting to the elbow. See Fig. 13. When ductwork is properly
aligned, connect the vertical duct to the horizontal trunk.

Seal Joints

Seal all joints in the return air system between the media air
cleaner and the furnace to prevent dust from entering the
clean airstream.

Assemble Expandapac Media Filter

1. Open the new media filter; expand it and set it upright

on a flat surface.

2. Insert one end panel tab into the retainers on the frame.

Fold in the end panel flanges and push the tab
completely in, making sure the end panel flanges are
inside the frame flanges. See Fig. 14.

3. Repeat step 2 on the opposite corner.

4. Flip over the assembly and repeat steps 2 and 3 on the

remaining two corners.

5. Lay the filter assembly down flat so the arrows point up.

Insert the combs as shown in Fig.15, aligning them with
the notches in the end panel flanges. Make sure the
combs are inserted completely.

Summary of Contents for F35F

Page 1: ...ing combs Combs are located down stream from filter so they stay clean Efficiency and arrestance ratings based on the American Society of Heating Refrigerating and Air Conditioning Engineers ASHRAE Standard 52 1 92 Initial Atmospheric Dust Spot Efficiency 25 8 Average Atmospheric Dust Spot Efficiency 32 0 Average Synthetic Dust Weight Arrestance 92 0 ASHRAE Dust Holding Capacity 55g The above data...

Page 2: ...hree sizes to fit most air ducts Compact packaging makes replacement media filters easy to fit on service trucks or mail to customers Replacement filter comes with bag to dispose of old filter FC35B Kit available to upgrade an F25F to an F35F requires FC35A Replacement Media Replacement Media Filter Order Number Size FC35A1001 16 x 25 FC35A1019 20 x 20 FC35A1027 20 x 25 Applicable to all gas oil a...

Page 3: ...ospheric Dust Spot Efficiency 32 0 Average Synthetic Dust Weight Arrestance 92 0 ASHRAE Dust Holding Capacity 55g The above data is for a 16 x 25 in filter The F35F removes particles as small as 1 0 microns Dimensions Fig 1 Installation dimensions in in mm of air cleaner Filter Media Expandapac Temperature Rating 40 F to 125 F 40 C to 52 C Capacity and Pressure Drop 400 600 800 1000 1200 1400 1600...

Page 4: ...least 26 in 660 mm clearance in front of the unit for removal of the filter Install the media air cleaner where the temperature will not exceed the ratings in the Specifications section Applications with Air Conditioning Mount the media air filter upstream of the evaporator coil in a cooling system The filter will help to keep the coil clean and reduce maintenance Applications with a Charcoal Filt...

Page 5: ...ening in closet door Fig 6 Lowboy furnace with media air cleaner mounted horizontally in return plenum just above furnace and opposite heating plenum Fig 7 Counterflow furnace with media air cleaner mounted horizontally in return duct or plenum just above furnace Fig 8 Central fan installation with media air cleaner mounted horizontally in central return duct M942A M943A M944A M6932 A ...

Page 6: ...rease efficiency See Fig 11 2 Use no more than 20 degrees about 4 in per running ft 100 mm per 300 linear mm of expansion on each side of a transition fitting Turning Vanes If the media air cleaner is installed next to an elbow or angle fitting add turning vanes inside the angle to distribute airflow more evenly across the face of the media See Fig 12 Offsets If the duct connection to the furnace ...

Page 7: ...der the cabinet as necessary to make sure the unit is seated securely Create an opening in the furnace to match the cabinet opening Attach the cabinet securely to the furnace Attach the unit directly or fit a starting collar in the furnace opening Either drill holes and fasten with sheet metal screws or rivets or use slip joints If you are drilling holes use a locking pliers to help hold the unit ...

Page 8: ... filter is installed downstream from an atomizing humidifier or if the installation includes both heating and cooling more frequent replacement may be necessary Clogged media filter must be replaced promptly to avoid restricting airflow and reducing efficiency of the heating cooling system Record the replacement date in the space provided on the replacement media filter Replace the Expandapac Medi...

Page 9: ...l Guarantee Protects your expensive HVAC equipment No on going filter replacements necessary because cells can be washed and restored to top efficiency Increases home comfort Easy to maintain And it s by Honeywell a leader in indoor air quality products for over 30 years High Efficiency Cleaning F50 Electronic Air Cleaner REPLACEMENT PARTS F35F part numbers are keyed to parts list F35F Replacement...

Page 10: ...F35F Expandapac MEDIA AIR CLEANER 68 0178 2 10 ...

Page 11: ...F35F Expandapac MEDIA AIR CLEANER 68 0178 2 11 ...

Page 12: ...Building Control Honeywell Limited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 68 0178 2 L C Rev 2 98 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www ho...

Reviews: