Components and Specification 

a. Case

 

b. Washer tank

 

a.  Water Jet Case 

Water Jet Case 

  Material 

  SUS316 

  Thickness 

  1.2mm 

  Size 

  350(W) x 340(H) x120(D)   (mm) 

  Weight 

  6.8kg 

Washer Tank 

  Material 

  PE 

  Size 

  260(W)x 192(H) x106(D) (mm) 

  Water Capacity 

  4.0L 

b . Washer Tank 

c . Nozzle 

Nozzle 

  Material 

  SUS316 

  Angle 

 Ø 1.0(Spread Aangle:0

°

c. Nozzle  bracket

 

d. Tube 

Tube 

  Size 

 Ø1/4”cm X 10m 

d. Tube

 

e. Bolt/Nut/Washers 

e. Tube 

Bolts, Nuts, Washers 

  Size 

 M8mm X 30mm 

  Quantity 

  6EA 

Summary of Contents for EXWJ400

Page 1: ... 1 EXWJ400 USER GUIDE BOOK Explosion proof Washer Pump ...

Page 2: ...DUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PRERSONNEL Explanation of Graphical Symbols This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is int...

Page 3: ...tion This system can be installed in a standard as below Figure1 If you wish to install another method you must do it after discussing with a manufacture And please refer to 7page for wiring cable connection with the NEXPTZ Camera Series which can be applied Figure1 Standard Method of Installation with NEXPTZ camera Series EXWJ400 NEXPTZ Camera ...

Page 4: ...stallation on the wall or for installation on the floor Nuts and flat Spring washers which are supplied The install bolts location of can be selected as the install environment of up or down location 2 Open the capacity of water tank and inject water until 4L and fit to the case Methods of Installation The liquid shall be used an antifreeze to endure below zero temperature 20 0 ...

Page 5: ...Size 350 W x 340 H x120 D mm Weight 6 8kg Washer Tank Material PE Size 260 W x 192 H x106 D mm Water Capacity 4 0L b Washer Tank c Nozzle Nozzle Material SUS316 Angle Ø 1 0 Spread Aangle 0 c Nozzle bracket d Tube Tube Size Ø1 4 cm X 10m d Tube e Bolt Nut Washers e Tube Bolts Nuts Washers Size M8mm X 30mm Quantity 6EA ...

Page 6: ...o clean any dried dust on the glass f Pump motor housing f Pump Motor Explosive proof Housing Explosive proof Housing Material AL6061 Thickness 12mm Size Ø 65mm x 188 L Weight 1 0kg IECEx Grade Exd IIC T6 IP Grade IP66 Operating Temp 20 60 The liquid shall be used an antifreeze to endure below zero temperature 20 0 Pump Motor Rated Voltage DC12 Input 20W Maximum Current 1 6A Maximum Capacity 1 2 ℓ...

Page 7: ... 232C ALARM DVR DC 12V SLAVE RS 485 Alram out B COM N O RS 485 DVR Check Valve Pump Motor GND Input Power DC 12V GND NEXPTZ Series EXWJ400 EXWJ400 Schematic CAUTION 1 If EXWJ400 is applied to NEXPTZ the alarm out B can t be used 2 It is recommended that the water Jet tank should be located on equal or lower under 12m level than the nozzle location ...

Page 8: ... 8 EXWJ400 Drawing ...

Page 9: ... of all The NEXPTZ pan tilt direction should be decided and saved that window glass of camera housing toward nozzle of water jet on preset 59 2 Push The 4 On button on HTX 5000 Keyboard Push the 88 preset button at Pelco protocol Result 1 Pan Tilt s moving to nozzle position location Preset 59 2 Auto Stop after Spray water Wiping 3 sec 6 Wiping 3 Pan Tilt s moving back to the previous position Hon...